A6 means the indoor blower motor is not operating or reporting normally. Filters are safe to check, but the motor, feedback wiring, and board are technician work.
- Urgency
- advisory
- Verified
- Jul 30, 2026
- Fix path
- Technician
What it means
A6 means the indoor blower motor is not operating or reporting normally. Filters are safe to check, but the motor, feedback wiring, and board are technician work.
Urgency
advisory
This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.
Likely causes
- Indoor/outdoor communication wiring or terminal problem
- Loose low-voltage connector after service or vibration
- Power interruption during the control handshake
- Indoor or outdoor control board fault after wiring is verified
Homeowner fix
Turn the unit off, clean the indoor filter, and check only for visible blockage at the return or outlet. Restart once; if the blower is noisy, stuck, or A6 returns, stop troubleshooting.
When to call a pro
Call a licensed HVAC technician if A6 returns or the indoor blower does not run normally. Tell them the code is indoor fan motor related.
This code points to electrical or inverter work - get repair quotes from contractors in your area.
Get repair quotesRepair vs replace
This is normally repairable, but it is not a homeowner repair. If the unit is older, out of warranty, or a technician quotes a major compressor, inverter, board, or sealed-system repair, compare the quote with replacement.
See Daikin mini-splitsYour Daikin model
AURORA R-32 model pages in the Daikin catalog help compare this repair path with current replacement options.
- Daikin AURORA 9,000 BTU R-32 208/230V (FTXV09AVJU9 / RXT09AVJU9)
AURORA R-32
- Daikin AURORA 12,000 BTU R-32 208/230V (FTXV12AVJU9 / RXT12AVJU9)
AURORA R-32
- Daikin AURORA 15,000 BTU R-32 208/230V (FTXV15AVJU9 / RXT15AVJU9)
AURORA R-32
- Daikin AURORA 18,000 BTU R-32 208/230V (FTXV18AVJU9 / RXT18AVJU9)
AURORA R-32
Parts for this line
The parts catalog for Daikin AURORA R-32 lists 7 sourced replacement parts for this product line.
Open parts pageFor your technician
Technician note: inspect indoor fan wheel, DC fan motor, feedback signal, harness, and indoor PCB fan output. Page context: Daikin maps this display to the AURORA R-32 line; source: Daikin Nineteen, ATMOSPHERA, Entra, and MXM/MXT/MXTH local service manuals; display convention: match the letter A and six marker exactly before comparing neighboring codes.
Which systems show it
- Daikin current US residential R-32 ductless single-zone systems, including AURORA R-32, ATMOSPHERA R-32, Entra R32, OTERRA R-32, and Nineteen-series style high-wall diagnostics where the same Daikin A/C/E/F/H/J/L/P/U code family is used.
- Daikin concealed-duct/FDMQ indoor units where the Nineteen service manual explicitly lists the same indoor drain, fan PCB, remote-controller, and FDMQ-only C/U codes.
- Daikin AURORA Multi R-32 and Standard Multi R-32 MXT/MXTH/MXM systems where the MXM engineering manual lists the same homeowner code table.
- MXM/MXT/MXTH multi-zone systems for the additional multi-zone U-series and inverter/control codes specifically called out from the MXM manual.
Related troubleshooting
Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.
Reset note
Turn the unit off, clean the indoor filter, and check only for visible blockage at the return or outlet. Restart once; if the blower is noisy, stuck, or A6 returns, stop troubleshooting.
Manual trigger
A6 means the indoor blower motor is not operating or reporting normally. Filters are safe to check, but the motor, feedback wiring, and board are technician work.
Related codes
Source
- Section
- Part 6 Service Diagnosis, troubleshooting for FTX/FVXS/FDMQ and outdoor unit
- Page
- PDF pages 137-196; service diagnosis pages 132-191
Short quote: "Troubleshooting"
Sourced Jul 2026