Daikin F6 error code
F6 means the system limited or stopped cooling because pressure/temperature conditions were too high. The safest homeowner check is airflow.
- Urgency
- advisory
- Verified
- Jul 30, 2026
- Fix path
- DIY
What it means
F6 means the system limited or stopped cooling because pressure/temperature conditions were too high. The safest homeowner check is airflow.
Urgency
advisory
This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.
Likely causes
- Dirty filters, blocked coil airflow, or an outdoor clearance problem increasing pressure or temperature
- Low charge, overcharge, leak, or refrigerant-flow restriction
- Discharge, pressure, or refrigerant sensor reading outside range
- Compressor, valve, or outdoor board issue after airflow and charge are verified
Homeowner fix
Turn the system off, clean the washable indoor filters, open blocked supply/return paths, and clear only loose leaves, snow, or debris around the outdoor unit without removing panels. Restore power once; if the code returns, stop there.
When to call a pro
Call a licensed HVAC technician if F6 returns after filters and outdoor clearance are corrected. Tell them the code is high-pressure control in cooling.
Repair vs replace
Airflow correction is low cost. If pressure controls, outdoor fan, or sealed-system work is quoted on older equipment, compare repair with replacement.
Your Daikin model
AURORA R-32 model pages in the Daikin catalog help compare this repair path with current replacement options.
- Daikin AURORA 9,000 BTU R-32 208/230V (FTXV09AVJU9 / RXT09AVJU9)
AURORA R-32
- Daikin AURORA 12,000 BTU R-32 208/230V (FTXV12AVJU9 / RXT12AVJU9)
AURORA R-32
- Daikin AURORA 15,000 BTU R-32 208/230V (FTXV15AVJU9 / RXT15AVJU9)
AURORA R-32
- Daikin AURORA 18,000 BTU R-32 208/230V (FTXV18AVJU9 / RXT18AVJU9)
AURORA R-32
Parts for this line
The parts catalog for Daikin AURORA R-32 lists 7 sourced replacement parts for this product line.
Open parts pageFor your technician
Technician note: check indoor/outdoor airflow, outdoor fan, coil condition, charge/restriction, pressure controls, and high-pressure logic. Page context: Daikin maps this display to the AURORA R-32 line; source: Daikin Nineteen, ATMOSPHERA, Entra, and MXM/MXT/MXTH local service manuals; display convention: match the letter F and six marker exactly before comparing neighboring codes.
Which systems show it
- Daikin current US residential R-32 ductless single-zone systems, including AURORA R-32, ATMOSPHERA R-32, Entra R32, OTERRA R-32, and Nineteen-series style high-wall diagnostics where the same Daikin A/C/E/F/H/J/L/P/U code family is used.
- Daikin concealed-duct/FDMQ indoor units where the Nineteen service manual explicitly lists the same indoor drain, fan PCB, remote-controller, and FDMQ-only C/U codes.
- Daikin AURORA Multi R-32 and Standard Multi R-32 MXT/MXTH/MXM systems where the MXM engineering manual lists the same homeowner code table.
- MXM/MXT/MXTH multi-zone systems for the additional multi-zone U-series and inverter/control codes specifically called out from the MXM manual.
Related troubleshooting
Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.
Reset note
Turn the system off, clean the washable indoor filters, open blocked supply/return paths, and clear only loose leaves, snow, or debris around the outdoor unit without removing panels. Restore power once; if the code returns, stop there.
Manual trigger
F6 means the system limited or stopped cooling because pressure/temperature conditions were too high. The safest homeowner check is airflow.
Related codes
Source
- Section
- Part 6 Service Diagnosis, troubleshooting for FTX/FVXS/FDMQ and outdoor unit
- Page
- PDF pages 137-196; service diagnosis pages 132-191
Short quote: "Troubleshooting"