SplitAtlas

Daikin / AURORA R-32

Daikin LC error code

LC means the inverter section and outdoor main control are not communicating normally. The outdoor unit may stop because compressor drive commands cannot be trusted.

Urgency
advisory
Verified
Jul 30, 2026
Fix path
Technician

What it means

LC means the inverter section and outdoor main control are not communicating normally. The outdoor unit may stop because compressor drive commands cannot be trusted.

Urgency

advisory

This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.

Likely causes

  1. Brief power event, brownout, or unstable supply voltage
  2. Loose power connection, reactor, or outdoor electrical component problem
  3. Inverter/IPM protection or current-detection fault
  4. Compressor winding, drive, or outdoor board fault after power checks pass

Homeowner fix

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

When to call a pro

Call a licensed HVAC technician if LC returns. Tell them the MXM table lists inverter-to-outdoor-control transmission.

This code points to compressor and electrical or inverter work - get repair quotes from contractors in your area.

Get repair quotes

Repair vs replace

This is normally repairable, but it is not a homeowner repair. If the unit is older, out of warranty, or a technician quotes a major compressor, inverter, board, or sealed-system repair, compare the quote with replacement.

See Daikin mini-splits

Your Daikin model

AURORA R-32 model pages in the Daikin catalog help compare this repair path with current replacement options.

Parts for this line

The parts catalog for Daikin AURORA R-32 lists 7 sourced replacement parts for this product line.

Open parts page

For your technician

Technician note: check inverter/control connectors, harness continuity, board power supplies, noise/grounding, and outdoor PCB/inverter board. Page context: Daikin maps this display to the AURORA R-32 line; source: Daikin Nineteen, ATMOSPHERA, Entra, and MXM/MXT/MXTH local service manuals; display convention: match the letter L and letter C marker exactly before comparing neighboring codes.

Which systems show it

  • Daikin current US residential R-32 ductless single-zone systems, including AURORA R-32, ATMOSPHERA R-32, Entra R32, OTERRA R-32, and Nineteen-series style high-wall diagnostics where the same Daikin A/C/E/F/H/J/L/P/U code family is used.
  • Daikin concealed-duct/FDMQ indoor units where the Nineteen service manual explicitly lists the same indoor drain, fan PCB, remote-controller, and FDMQ-only C/U codes.
  • Daikin AURORA Multi R-32 and Standard Multi R-32 MXT/MXTH/MXM systems where the MXM engineering manual lists the same homeowner code table.
  • MXM/MXT/MXTH multi-zone systems for the additional multi-zone U-series and inverter/control codes specifically called out from the MXM manual.

Related troubleshooting

Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.

Reset note

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

Manual trigger

LC means the inverter section and outdoor main control are not communicating normally. The outdoor unit may stop because compressor drive commands cannot be trusted.

Related codes

Source

Daikin MXM-A, MXT-A, MXTH-A Series Engineering Manual EDUS122402
Section
BRC944B2 operation, malfunction code table
Page
PDF pages 267-269

Short quote: "Malfunction code Error content"

Sourced Jul 2026

Next step