Bosch Climate 5000 systems show an alphanumeric code on the indoor unit display. The 18 codes below cover the Gen 4 range plus the remaining legacy R-410A systems. Bosch's code set is smaller than most brands' here, which reflects a simpler product family rather than thinner documentation - Climate 5000 is essentially one line.

Status displays
0
Error codes
18

Unit applicability

Match your unit before reading the table

This table is sourced for Climate 5000 A/B legacy R-410A. If your unit is a different generation or product line not named here, the same display code may vary by generation.

Common codes first

Most broadly applicable documented codes

Ranking basis: we do not have failure-frequency telemetry. These are ordered by breadth of affected systems in the SplitAtlas catalog - the documented product line's published model count, whether the same code appears on more than one product line, and any manual applicability notes we hold. This is a breadth ranking, not a popularity claim.

E0

E0 means indoor unit eeprom error. In plain English, a control board, EEPROM, or board sensing circuit is not reading internal data correctly.

AdvisoryTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. If the code returns, stop resetting and schedule service.
View the fix
E1

E1 means communication error between indoor unit and outdoor units. In plain English, the indoor and outdoor controls are not exchanging the expected signal, so the system may stop because the two halves cannot coordinate safely.

AdvisoryTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off, then power cycle once at the breaker or disconnect if you can do that safely. Do not open wiring covers or touch the communication cable.
View the fix
E3

E3 means indoor fan speed error. In plain English, a fan is not moving at the speed the control expects, so the system may stop to protect the coil, compressor, or inverter electronics.

AdvisoryTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off. Clear only loose, obvious debris outside the cabinet or from the user-accessible intake area; do not remove panels. Reset once if safe.
View the fix
E4

E4 means indoor return air temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
View the fix
E5

E5 means indoor coil temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
View the fix
EC

EC means low refrigerant. In plain English, the unit is detecting abnormal refrigerant flow, low refrigerant, or a cooling-system condition.

Stop useTechnician
Breadth evidence
2 published catalog models on its documented product line.
Safe first check
Turn the system off. Do not attach gauges, open service valves, add refrigerant, or keep resetting the unit.
View the fix

Safe first checks

Checks you can do without opening the unit

These codes have homeowner-safe steps such as filters, airflow, condensate/drain checks, remote/controller items, or a single safe power reset. If the code returns, stop at the boundary in the card.

E0Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. If the code returns, stop resetting and schedule service.

Read the full code guide
E3Technician

Turn the system off. Clear only loose, obvious debris outside the cabinet or from the user-accessible intake area; do not remove panels. Reset once if safe.

Read the full code guide
E4Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.

Read the full code guide
E5Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.

Read the full code guide

Bosch mini-splits

Use the Bosch catalog to connect these manual error codes to current model pages and replacement options.

All error codes

E0

E0 means indoor unit eeprom error. In plain English, a control board, EEPROM, or board sensing circuit is not reading internal data correctly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. If the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if E0 returns after one safe reset or the condition will not clear. Tell them the official source lists E0 as Indoor unit EEPROM error.
View the fix ->

E1

E1 means communication error between indoor unit and outdoor units. In plain English, the indoor and outdoor controls are not exchanging the expected signal, so the system may stop because the two halves cannot coordinate safely.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off, then power cycle once at the breaker or disconnect if you can do that safely. Do not open wiring covers or touch the communication cable.
When to call a pro
Call a licensed HVAC technician if E1 returns after one safe reset or the condition will not clear. Tell them the official source lists E1 as Communication error between indoor unit and outdoor units.
View the fix ->

E3

E3 means indoor fan speed error. In plain English, a fan is not moving at the speed the control expects, so the system may stop to protect the coil, compressor, or inverter electronics.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off. Clear only loose, obvious debris outside the cabinet or from the user-accessible intake area; do not remove panels. Reset once if safe.
When to call a pro
Call a licensed HVAC technician if E3 returns after one safe reset or the condition will not clear. Tell them the official source lists E3 as Indoor fan speed error.
View the fix ->

E4

E4 means indoor return air temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if E4 returns after one safe reset or the condition will not clear. Tell them the official source lists E4 as Indoor return air temperature sensor error.
View the fix ->

E5

E5 means indoor coil temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if E5 returns after one safe reset or the condition will not clear. Tell them the official source lists E5 as Indoor coil temperature sensor error.
View the fix ->

EC

EC means low refrigerant. In plain English, the unit is detecting abnormal refrigerant flow, low refrigerant, or a cooling-system condition.

Stop useTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off. Do not attach gauges, open service valves, add refrigerant, or keep resetting the unit.
When to call a pro
Call a licensed HVAC technician if EC returns after one safe reset or the condition will not clear. Tell them the official source lists EC as Low refrigerant.
View the fix ->

F0

F0 means outdoor current overload sensed. In plain English, the outdoor unit detected voltage or current outside the safe operating range.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Power cycle once at the breaker or disconnect if you can do that safely. If the code returns, the breaker trips, or other home electrical symptoms appear, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if F0 returns after one safe reset or the condition will not clear. Tell them the official source lists F0 as Outdoor current overload sensed.
View the fix ->

F1

F1 means outdoor ambient temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if F1 returns after one safe reset or the condition will not clear. Tell them the official source lists F1 as Outdoor ambient temperature sensor error.
View the fix ->

F2

F2 means outdoor coil temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if F2 returns after one safe reset or the condition will not clear. Tell them the official source lists F2 as Outdoor coil temperature sensor error.
View the fix ->

F3

F3 means compressor discharge temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if F3 returns after one safe reset or the condition will not clear. Tell them the official source lists F3 as Compressor discharge temperature sensor error.
View the fix ->

F4

F4 means outdoor unit eeprom error. In plain English, a control board, EEPROM, or board sensing circuit is not reading internal data correctly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. If the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F4 returns after one safe reset or the condition will not clear. Tell them the official source lists F4 as Outdoor unit EEPROM error.
View the fix ->

F5

F5 means outdoor unit fan speed error. In plain English, a fan is not moving at the speed the control expects, so the system may stop to protect the coil, compressor, or inverter electronics.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off. Clear only loose, obvious debris outside the cabinet or from the user-accessible intake area; do not remove panels. Reset once if safe.
When to call a pro
Call a licensed HVAC technician if F5 returns after one safe reset or the condition will not clear. Tell them the official source lists F5 as Outdoor unit fan speed error.
View the fix ->

F6

F6 means indoor coil outlet temperature sensor error. In plain English, the named temperature or air-quality sensor is not sending a believable reading, so the control cannot trust that part of the system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Do not open covers, unplug sensors, or spray cleaner into the sensor area.
When to call a pro
Call a licensed HVAC technician if F6 returns after one safe reset or the condition will not clear. Tell them the official source lists F6 as Indoor coil outlet temperature sensor error.
View the fix ->

P0

P0 means inverter module ipm error. In plain English, the outdoor inverter, IPM module, or compressor drive circuit is reporting abnormal load or protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off and power cycle once only if you can do that safely. If the code returns, do not keep forcing restarts and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if P0 returns after one safe reset or the condition will not clear. Tell them the official source lists P0 as Inverter module IPM error.
View the fix ->

P1

P1 means high or low voltage protection. In plain English, the outdoor unit detected voltage or current outside the safe operating range.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Power cycle once at the breaker or disconnect if you can do that safely. If the code returns, the breaker trips, or other home electrical symptoms appear, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if P1 returns after one safe reset or the condition will not clear. Tell them the official source lists P1 as High or low voltage protection.
View the fix ->

P3

P3 means outdoor unit low temperature lockout. In plain English, outdoor temperature is outside the range the unit allows, or the outdoor unit is reading it that way.

AdvisoryDIY
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Wait for outdoor conditions to improve. Make sure the outdoor unit has open air around it and is not packed with debris or snow; do not remove panels.
When to call a pro
Call a licensed HVAC technician if P3 returns after one safe reset or the condition will not clear. Tell them the official source lists P3 as Outdoor unit low temperature lockout.
View the fix ->

P4

P4 means compressor drive error. In plain English, the compressor drive is reporting abnormal feedback or load.

Stop useTechnician
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Turn the system off and wait at least 3 minutes before one safe reset. If the code returns, do not keep forcing starts.
When to call a pro
Call a licensed HVAC technician if P4 returns after one safe reset or the condition will not clear. Tell them the official source lists P4 as Compressor drive error.
View the fix ->

P5

P5 means mode conflict. In plain English, connected indoor units are asking for incompatible operation, such as heat from one room and cooling or dry mode from another.

AdvisoryDIY
Sourced Jul 2026
Applies to
Climate 5000 A/B legacy R-410A
Homeowner fix
Set every connected indoor unit on the same outdoor system to the same mode, such as all Cool, all Heat, or all Off. Wait several minutes, then reset once if needed.
When to call a pro
Call a licensed HVAC technician if P5 returns after one safe reset or the condition will not clear. Tell them the official source lists P5 as Mode conflict.
View the fix ->