SplitAtlas

MRCOOL / DIY 5th Generation

EH 02 error code

The indoor PCB does not receive zero-crossing signal feedback for 4 minutes or the zero-crossing signal interval is abnormal.

Severity
technician
Verified
Jul 18, 2026

What triggers it

The indoor PCB does not receive zero-crossing signal feedback for 4 minutes or the zero-crossing signal interval is abnormal.

What to do

  1. Check the wiring connections and the power supply.
  2. If wiring or power supply is not normal, correct the connections and turn the unit on when the power supply is good.
  3. If wiring and power supply are normal, replace the indoor main PCB.

Which systems show it

  • Units with an AC fan motor; the manual says this error is invalid for other models.

Related codes

Technician scope

Indoor PCB

Source

MRCOOL R454B DIY-5 service manual
Document
data/sources/mrcool-diy5-service.pdf
Section
4.7 TS03: Zero crossing signal detection error diagnosis and solution
Page
58
Verified Jul 2026

Next step