EH60 means the indoor unit cannot trust the room-temperature sensor. Comfort can swing or the unit may stop because it does not know the room temperature accurately.

Urgency
advisory
Verified
Jul 30, 2026
Fix path
Technician

What it means

EH60 means the indoor unit cannot trust the room-temperature sensor. Comfort can swing or the unit may stop because it does not know the room temperature accurately.

Urgency

advisory

This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.

Likely causes

  1. Brief power event, brownout, or unstable supply voltage
  2. Loose power connection, reactor, or outdoor electrical component problem
  3. Inverter/IPM protection or current-detection fault
  4. Compressor winding, drive, or outdoor board fault after power checks pass

Homeowner fix

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

When to call a pro

Call a licensed HVAC technician if EH60 returns after one reset. Tell them the code points to indoor room sensor T1.

This code points to compressor and electrical or inverter work - get repair quotes from contractors in your area.

Get repair quotes

Repair vs replace

Sensor and communication faults are usually repairable. Compare repair with replacement only if the system is older, out of warranty, or multiple boards/sensors are being quoted together.

See ACiQ mini-splits

Your ACiQ model

Multi-Zone Extreme Series model pages in the ACiQ catalog help compare this repair path with current replacement options.

For your technician

Technician note: section 7.4.1.5 uses the 0.06V to 4.94V sampling-voltage rule for indoor temperature-sensor faults. Page context: ACiQ maps this display to the Multi-Zone Extreme Series line; source: ACiQ Multi-Zone Service Manual and shared Midea D5CMRA Table 20 display reference; display convention: match the letter E, letter H, and sixty marker exactly before comparing neighboring codes.

Which systems show it

  • ACiQ Multi-Zone Extreme Series R-454B systems using the shared Midea/ACiQ multi-zone platform.
  • ACiQ Multi-Zone Standard Series R-454B systems where the ACiQ service manual lists the same EC/EH/EL/PC diagnostics.
  • ACiQ wall-mounted, cassette, duct, console, and AHU indoor units listed in service manual section 7.2.

Sold under more than one brand

Shared with Midea. ACiQ and Midea document this code from the same manufacturer source, so EH60 means the same thing on either badge and the steps above apply.

Open Midea EH60

Related troubleshooting

Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.

Reset note

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

Manual trigger

EH60 means the indoor unit cannot trust the room-temperature sensor. Comfort can swing or the unit may stop because it does not know the room temperature accurately.

Related codes

Source

ACiQ Multi-Zone Service Manual; Midea D5CMRA Installation Instructions
Section
Midea Table 20; ACiQ service manual sections 7.2 and 7.4.1.5
Page
Midea PDF page 37; ACiQ PDF pages 51-53; ACiQ PDF page 73

Short quote: "Indoor room temperature sensor (T1) malfunction."

Sourced Jul 2026