Blueridge shows an alphanumeric code on the indoor display, and the 6 codes below are those published in homeowner-facing documentation across the XS, XM, DS and DM ranges. The set is small because Blueridge's public literature is limited. If your code is not here, the model's own manual from your retailer is the right source - do not read across from another brand.

Status displays
1
Error codes
6

Unit applicability

Match your unit before reading the table

This table is sourced for Blueridge XS2 Core. If your unit is a different generation or product line not named here, the same display code may vary by generation.

Common codes first

Most broadly applicable documented codes

Ranking basis: we do not have failure-frequency telemetry. These are ordered by breadth of affected systems in the SplitAtlas catalog - the documented product line's published model count, whether the same code appears on more than one product line, and any manual applicability notes we hold. This is a breadth ranking, not a popularity claim.

ECC1

ECC1 is used on multi-zone systems when another indoor unit refrigerant sensor detects leakage. The alarm may show on one zone even though the leak alarm originates at a different indoor unit.

Stop useTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off if safe and ventilate rooms served by the connected indoor units. Do not open any indoor unit or restart the system repeatedly.
View the fix
EHC1

EHC1 is a refrigerant leak alarm from the indoor unit sensor. The XS2A manual says the outdoor compressor stops and the indoor fan starts when the refrigerant sensor detects leakage.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off from the remote or breaker if safe, open windows if you notice odor or irritation, and keep ignition sources away from the indoor unit area. Do not open panels.
View the fix
EHC2

EHC2 combines two problems: the refrigerant sensor is outside its expected working condition and leakage is detected. Treat it as both a leak alarm and a sensor diagnostic.

Stop useTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off if safe, ventilate the room, and avoid using the unit until a technician checks it. Do not open panels or bypass alarms.
View the fix
EHC3

EHC3 means the refrigerant sensor itself is not operating in the expected range. The manual states the sensor cannot be repaired and must be replaced with the manufacturer-specified part if it malfunctions.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Stop using the unit if the code remains after a single safe power reset. Do not open the indoor unit or disconnect the sensor.
View the fix
EL0C

EL0C means the Blueridge unit has detected that the system lacks refrigerant. The same manual also lists low refrigerant from leak or long-term use and too little refrigerant as causes of poor operation.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the unit off if it is not heating or cooling normally or if ice is present. Check only that filters are clean and airflow is not blocked. Do not add refrigerant.
View the fix
FHCC

FHCC means the indoor unit has detected a refrigerant sensor malfunction. The manual says the sensor cannot be repaired and must be replaced with the manufacturer-specified sensor.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Power cycle once only if safe. If FHCC remains or returns, leave the unit off and do not open the indoor unit.
View the fix

Safe first checks

Checks you can do without opening the unit

These codes have homeowner-safe steps such as filters, airflow, condensate/drain checks, remote/controller items, or a single safe power reset. If the code returns, stop at the boundary in the card.

EHC3Technician

Stop using the unit if the code remains after a single safe power reset. Do not open the indoor unit or disconnect the sensor.

Read the full code guide
FHCCTechnician

Power cycle once only if safe. If FHCC remains or returns, leave the unit off and do not open the indoor unit.

Read the full code guide

Blueridge mini-splits

Use the Blueridge catalog to connect these manual error codes to current model pages and replacement options.

Status displays

CL

CL is a normal Blueridge display for the Active Clean function. The manual says the indoor display shows CL while the unit cleans the heat exchanger, then shuts off and cancels the function after about 20 to 45 minutes.

Not an error
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Let the cycle finish unless you intentionally want to cancel Active Clean from the remote.
Status note
No fault action is needed while Active Clean is running.
View the fix ->

All error codes

ECC1

ECC1 is used on multi-zone systems when another indoor unit refrigerant sensor detects leakage. The alarm may show on one zone even though the leak alarm originates at a different indoor unit.

Stop useTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Turn the system off if safe and ventilate rooms served by the connected indoor units. Do not open any indoor unit or restart the system repeatedly.
When to call a pro
Call a licensed HVAC technician promptly and mention that ECC1 refers to another indoor unit refrigerant sensor detecting leakage.
View the fix ->

EHC1

EHC1 is a refrigerant leak alarm from the indoor unit sensor. The XS2A manual says the outdoor compressor stops and the indoor fan starts when the refrigerant sensor detects leakage.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Turn the system off from the remote or breaker if safe, open windows if you notice odor or irritation, and keep ignition sources away from the indoor unit area. Do not open panels.
When to call a pro
Call a licensed HVAC technician promptly. Tell them the Blueridge manual defines EHC1 as refrigerant sensor detects leakage.
View the fix ->

EHC2

EHC2 combines two problems: the refrigerant sensor is outside its expected working condition and leakage is detected. Treat it as both a leak alarm and a sensor diagnostic.

Stop useTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Turn the system off if safe, ventilate the room, and avoid using the unit until a technician checks it. Do not open panels or bypass alarms.
When to call a pro
Call a licensed HVAC technician promptly. Tell them the Blueridge manual defines EHC2 as sensor out of range with leakage detected.
View the fix ->

EHC3

EHC3 means the refrigerant sensor itself is not operating in the expected range. The manual states the sensor cannot be repaired and must be replaced with the manufacturer-specified part if it malfunctions.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Stop using the unit if the code remains after a single safe power reset. Do not open the indoor unit or disconnect the sensor.
When to call a pro
Call a licensed HVAC technician if EHC3 appears. Tell them the Blueridge manual says the refrigerant sensor condition is out of range.
View the fix ->

EL0C

EL0C means the Blueridge unit has detected that the system lacks refrigerant. The same manual also lists low refrigerant from leak or long-term use and too little refrigerant as causes of poor operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Turn the unit off if it is not heating or cooling normally or if ice is present. Check only that filters are clean and airflow is not blocked. Do not add refrigerant.
When to call a pro
Call a licensed HVAC technician if EL0C appears. Tell them the Blueridge XS2A manual defines EL0C as system lacks refrigerant.
View the fix ->

FHCC

FHCC means the indoor unit has detected a refrigerant sensor malfunction. The manual says the sensor cannot be repaired and must be replaced with the manufacturer-specified sensor.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Blueridge XS2 Core
Homeowner fix
Power cycle once only if safe. If FHCC remains or returns, leave the unit off and do not open the indoor unit.
When to call a pro
Call a licensed HVAC technician if FHCC appears. Tell them the Blueridge manual identifies FHCC as refrigerant sensor malfunction.
View the fix ->