The outdoor voltage detection circuit detects abnormal increases or decreases in voltage.

Severity
technician
Verified
Jul 18, 2026

What triggers it

The outdoor voltage detection circuit detects abnormal increases or decreases in voltage.

What to do

  1. Check the power supply; if it is not working, turn off the unit.
  2. Check power-supply connections and wires; correct connections or replace wires if needed.
  3. Power on and measure P-N voltage where applicable.
  4. Replace the IPM board if P-N voltage is abnormal.
  5. Check the reactor; replace the reactor if it is not normal, otherwise replace the outdoor PCB.

Which systems show it

  • MRCOOL DIY 5th Generation single-zone 9k, 12k, 18k, 24k, and 36k D25 indoor/outdoor models listed in manual section 1.1.

Related codes

Technician scope

Reactor, IPM, PCB

Source

MRCOOL R454B DIY-5 service manual
Document
data/sources/mrcool-diy5-service.pdf
Section
4.7 TS10-S: Over voltage or too low voltage protection diagnosis and solution