Toshiba Carrier / Toshiba Carrier 26 High Wall
Toshiba Carrier F10 error code
The Toshiba Carrier table lists F10 as indoor room temperature sensor TA error. It says an open or short circuit has been detected and lists the TA room temperature sensor and indoor PCB as parts to check.
- Urgency
- advisory
- Verified
- Jul 31, 2026
- Fix path
- Technician
What it means
The Toshiba Carrier table lists F10 as indoor room temperature sensor TA error. It says an open or short circuit has been detected and lists the TA room temperature sensor and indoor PCB as parts to check.
Urgency
advisory
Indoor sensor service is needed if one safe reset does not clear it.
Likely causes
- The indoor room-temperature TA sensor circuit is open or shorted
- The TA sensor connector or harness needs service
- The indoor PCB sensor input needs service
Homeowner fix
Power cycle once if you can do that safely. Keep the indoor unit clear of heat sources and blocked airflow, but do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if F10 returns. Tell them Toshiba Carrier identifies F10 as indoor room-temperature TA sensor error.
This code points to electrical or inverter work - get repair quotes from contractors in your area.
Get repair quotesRepair vs replace
Room sensor faults are usually repairable. Replacement is rarely justified unless an old unit also needs control-board replacement.
See Toshiba Carrier mini-splitsYour Toshiba Carrier model
Toshiba Carrier 26 High Wall model pages in the Toshiba Carrier catalog help compare this repair path with current replacement options.
- Toshiba Carrier 26 High Wall 12,000 BTU R-454B 208/230V (RAV-HB121KRTP-UL / RAV-BP121AT2P-UL)
Toshiba Carrier 26 High Wall
- Toshiba Carrier 26 High Wall 18,000 BTU R-454B 208/230V (RAV-HB181KRTP-UL / RAV-BP181AT2P-UL)
Toshiba Carrier 26 High Wall
- Toshiba Carrier 26 High Wall 24,000 BTU R-454B 208/230V (RAV-HB241KRTP-UL / RAV-BP241AT2P-UL)
Toshiba Carrier 26 High Wall
- Toshiba Carrier 26 High Wall 30,000 BTU R-454B 208/230V (RAV-HB301KRTP-UL / RAV-BP301AT2P-UL)
Toshiba Carrier 26 High Wall
For your technician
Technician note: inspect TA room-temperature sensor, connector, harness, sensor placement, and indoor PCB input for open/short detection. Page context: Toshiba Carrier maps this display to the Toshiba Carrier 26 High Wall line; source: Toshiba Carrier RAV High Wall 12K-36K Installation Manual, Section 14 Troubleshooting, Error codes and parts to be checked; display convention: match the letter F and ten marker exactly before comparing neighboring codes.
Which systems show it
Toshiba Carrier 26 High Wall
Related troubleshooting
Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.
Related codes
Source
- Document
- Toshiba Carrier RAV High Wall 12K-36K Installation Manual, Section 14 Troubleshooting, Error codes and parts to be checked