Mitsubishi Electric error codes

Mitsubishi Electric systems report faults two ways: M-Series wall units flash the operation and timer LEDs in a counted pattern, while MXZ multi-zone condensers and wired controllers show an alphanumeric code directly. The 59 codes below are drawn from Mitsubishi's own service documentation. Note that Trane's ML Series is Mitsubishi-built, so its codes closely resemble these - but check the Trane pages for that brand's own wording.

Status displays
14
Error codes
59

Unit applicability

Match your unit before reading the table

This hub has separate sourced tables for M-Series GX and MXZ-D Ported Multi-Zone. Select the product line that matches your indoor or outdoor unit before comparing codes.

Common codes first

Most broadly applicable documented codes

Ranking basis: we do not have failure-frequency telemetry. These are ordered by breadth of affected systems in the SplitAtlas catalog - the documented product line's published model count, whether the same code appears on more than one product line, and any manual applicability notes we hold. This is a breadth ranking, not a popularity claim.

E6

E6 means the indoor head stopped receiving the outdoor unit serial communication signal. To a homeowner, that usually means the two halves of the mini split are powered but are no longer confirming each other. The code does not identify which side failed; it tells you the communication path needs diagnosis if one reset does not hold. Manual trigger: Serial signal from the outdoor unit is not received by the indoor unit for a maximum of 6 minutes.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric MSZ-GX R454B wall-mounted indoor units covered by OBH950B; common M-Series wall-mount diagnostics apply where matched by model manual.
Safe first check
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
View the fix
E7

E7 means the indoor and outdoor units are not exchanging serial communication normally. The system cannot trust the conversation between the two units, so it stops instead of running blind. A reset can clear a temporary handshake fault, but repeated E7 is a wiring or board diagnosis. Manual trigger: Serial signal communication between the indoor and outdoor units is abnormal.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric MSZ-GX R454B wall-mounted indoor units covered by OBH950B; common M-Series wall-mount diagnostics apply where matched by model manual.
Safe first check
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
View the fix
E8

E8 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: Any signal from the inverter P.C. board cannot be received normally for 3 minutes.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric M-Series R454B wall-mount outdoor units covered by MUZ-GX OBH951C and cross-checked against MUZ-FX OBH946C and MUZ-WX OBH955A.
Safe first check
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
View the fix
E9

E9 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: The outdoor inverter sends signal 0 but signal 1 is received 30 consecutive times.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric M-Series R454B wall-mount outdoor units covered by MUZ-GX OBH951C and cross-checked against MUZ-FX OBH946C and MUZ-WX OBH955A.
Safe first check
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
View the fix
EC

EC means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: The start-up process of the outdoor unit does not complete for 4 minutes.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric M-Series R454B wall-mount outdoor units covered by MUZ-GX OBH951C and cross-checked against MUZ-FX OBH946C and MUZ-WX OBH955A.
Safe first check
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
View the fix
EE

EE means the indoor and outdoor units are not an allowed refrigerant-type or model combination. This is not wear and tear; it usually points to an installation, replacement, or pairing problem. Running mismatched equipment can create reliability and safety problems. Manual trigger: The refrigerant types specified for the connected indoor and outdoor units do not match.

Stop useTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: Mitsubishi Electric MSZ-GX R454B wall-mounted indoor units covered by OBH950B; common M-Series wall-mount diagnostics apply where matched by model manual.
Safe first check
Turn the system off and do not keep testing modes or resets. Expected result: the compressor and electronics are protected until the installation or equipment mismatch is corrected.
View the fix

Safe first checks

Checks you can do without opening the unit

These codes have homeowner-safe steps such as filters, airflow, condensate/drain checks, remote/controller items, or a single safe power reset. If the code returns, stop at the boundary in the card.

P8DIY part

Clean the indoor filters. If the air-cleaning filter is packed with dust, tobacco tar, oil, or damage that cleaning will not remove, replace that user-serviceable filter before resetting once. Make sure louvers and return air are not blocked. Expected result: if airflow recovers, the code clears; if P8 returns, stop there.

Sourced homeowner part

Mitsubishi microparticle filter

View sourced part route
Read the full code guide
E6Technician

Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.

Read the full code guide
E7Technician

Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.

Read the full code guide
E8Technician

Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.

Read the full code guide

Mitsubishi Electric mini-splits

Use the Mitsubishi Electric catalog to connect these manual error codes to current model pages and replacement options.

Status displays

00

00 means the controller has no current matching memorized error. The system is not reporting an active fault from that recall screen.

Not an error
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
No repair action is needed. If the system is comfortable and running normally, leave it alone.
Status note
This is a normal status indication, not an error, unless comfort is poor or the indication never clears.
View the fix ->

LAST ERROR STORED

The remote can show the last memorized error even after the current fault has cleared. This is history, not proof that the system is still broken right now.

Not an error
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Observe current operation and write down the stored code for the technician if service is already scheduled.
Status note
This is a normal status indication, not an error, unless comfort is poor or the indication never clears.
View the fix ->

LED1 LIT AND LED2 LIT

LED1 lit and LED2 lit is the normal outdoor control board indication for this MXZ-D table. It is not an error by itself.

Not an error
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
No repair action is needed if the system is operating normally.
Status note
This is a normal status indication, not an error, unless comfort is poor or the indication never clears.
View the fix ->

MXZ MODE CONFLICT

MXZ mode conflict means indoor heads are asking for incompatible modes, such as one zone calling for cooling while another calls for heating. That is a coordination status, not a failed part.

Not an error
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Set all connected indoor heads to the same mode, then wait several minutes for operation to resume.
Status note
This is a normal status indication, not an error, unless comfort is poor or the indication never clears.
View the fix ->

OUTDOOR LED LIT

A steady outdoor LED can be a normal outdoor board indication during operation. By itself, it is not an error code.

Not an error
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
No repair action is needed if the unit is heating or cooling normally.
Status note
This is a normal status indication, not an error, unless comfort is poor or the indication never clears.
View the fix ->

Error codes by unit family

Choose the product line that matches your unit, then use the full code list below. The catalog is preserved; the grouping is only to keep generation and model applicability visible.

M-Series GX

32 error codes / 12 catalog models tied to this line.

EE

EE means the indoor and outdoor units are not an allowed refrigerant-type or model combination. This is not wear and tear; it usually points to an installation, replacement, or pairing problem. Running mismatched equipment can create reliability and safety problems. Manual trigger: The refrigerant types specified for the connected indoor and outdoor units do not match.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off and do not keep testing modes or resets. Expected result: the compressor and electronics are protected until the installation or equipment mismatch is corrected.
When to call a pro
Call the installing contractor, Mitsubishi dealer, or licensed HVAC technician before running it again. Tell them the exact Mitsubishi stop-use code and whether installation or service happened recently.
View the fix ->

FD

FD means the outdoor unit is connected to the wrong supply voltage. This is not a nuisance code; wrong voltage can damage the inverter and compressor. Leave the system off until the electrical supply and model requirements are verified.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off and do not keep testing modes or resets. Expected result: the compressor and electronics are protected until the installation or equipment mismatch is corrected.
When to call a pro
Call the installing contractor, Mitsubishi dealer, or licensed HVAC technician before running it again. Tell them the exact Mitsubishi stop-use code and whether installation or service happened recently.
View the fix ->

FH

FH means the refrigerant sensor is not working, not connected, or has a broken wire. Even when it is a sensor fault rather than a confirmed leak, the system has lost an important R454B safety monitor. Do not run it as normal until the sensor circuit is confirmed.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Ventilate the room, avoid flames or spark sources, let any automatic fan safety operation run, and do not use normal heating or cooling. Expected result: people are protected while a qualified technician verifies the leak or sensor condition.
When to call a pro
Call a licensed HVAC technician before using the system normally. Tell them the exact Mitsubishi code and that it involves R454B refrigerant detection, leak sensing, or refrigerant-system abnormality.
View the fix ->

FL

FL means the indoor refrigerant sensor detected refrigerant leakage. Because these current Mitsubishi systems use R454B, the alarm deserves immediate safety treatment even if you do not smell anything. Ventilation and a qualified technician matter more than clearing the code. Manual trigger: The indoor refrigerant sensor detects refrigerant leakage.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Ventilate the room, avoid flames or spark sources, let any automatic fan safety operation run, and do not use normal heating or cooling. Expected result: people are protected while a qualified technician verifies the leak or sensor condition.
When to call a pro
Call a licensed HVAC technician before using the system normally. Tell them the exact Mitsubishi code and that it involves R454B refrigerant detection, leak sensing, or refrigerant-system abnormality.
View the fix ->

PL

PL means the outdoor unit detected a refrigerant-system abnormality, with the manual pointing to conditions such as a closed valve or trapped air. For a homeowner, the important point is that refrigerant flow is not normal and continued operation can damage the system. Treat it as a stop-and-call code, not a reset-and-ignore code. Manual trigger: The outdoor unit detects an outdoor refrigerant-system abnormality, including closed valve or trapped air conditions.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Ventilate the room, avoid flames or spark sources, let any automatic fan safety operation run, and do not use normal heating or cooling. Expected result: people are protected while a qualified technician verifies the leak or sensor condition.
When to call a pro
Call a licensed HVAC technician before using the system normally. Tell them the exact Mitsubishi code and that it involves R454B refrigerant detection, leak sensing, or refrigerant-system abnormality.
View the fix ->

UE

UE means the outdoor unit detected a stop-valve or closed-valve condition. That can prevent refrigerant from moving correctly and can damage the compressor if the system keeps trying to run. This is especially important after installation, service, or a recent move of the outdoor unit. Manual trigger: The outdoor unit detects a stop-valve or closed-valve condition.

Stop useTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off and do not keep testing modes or resets. Expected result: the compressor and electronics are protected until the installation or equipment mismatch is corrected.
When to call a pro
Call the installing contractor, Mitsubishi dealer, or licensed HVAC technician before running it again. Tell them the exact Mitsubishi stop-use code and whether installation or service happened recently.
View the fix ->

E6

E6 means the indoor head stopped receiving the outdoor unit serial communication signal. To a homeowner, that usually means the two halves of the mini split are powered but are no longer confirming each other. The code does not identify which side failed; it tells you the communication path needs diagnosis if one reset does not hold. Manual trigger: Serial signal from the outdoor unit is not received by the indoor unit for a maximum of 6 minutes.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

E7

E7 means the indoor and outdoor units are not exchanging serial communication normally. The system cannot trust the conversation between the two units, so it stops instead of running blind. A reset can clear a temporary handshake fault, but repeated E7 is a wiring or board diagnosis. Manual trigger: Serial signal communication between the indoor and outdoor units is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

E8

E8 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: Any signal from the inverter P.C. board cannot be received normally for 3 minutes.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

E9

E9 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: The outdoor inverter sends signal 0 but signal 1 is received 30 consecutive times.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

EC

EC means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: The start-up process of the outdoor unit does not complete for 4 minutes.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

FB

FB means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The indoor electronic control P.C. board cannot read nonvolatile memory data properly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

FC

FC means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The outdoor inverter P.C. board cannot read nonvolatile memory data properly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

P1

P1 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The room temperature thermistor is detected shorted or open every 8 seconds during operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

P2

P2 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: An indoor coil thermistor is detected shorted or open every 8 seconds during operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

P4

P4 means the indoor unit sees a drain, drain-sensor, or indoor valve signal problem. If water cannot leave the unit or a drain sensor cannot be trusted, the system may stop to prevent overflow or abnormal operation. Check for visible water or a blocked drain outlet only from outside the cabinet. Manual trigger: Drain sensor connector CN1S1 is open for more than 3 minutes.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
If you see water at the indoor head, turn the system off. Check only for an obvious blocked drain outlet or overflowing pan; if water is present or the code remains, leave it off.
When to call a pro
Call a licensed HVAC technician if water is present, the indoor head is dripping, or the code returns. Tell them the code points to the drain sensor, drain pump, or indoor LEV/drain circuit.
View the fix ->

P9

P9 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The alternate indoor coil thermistor code is detected for the indoor coil thermistor short/open condition.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

PB

PB means the indoor blower is not operating or reporting speed normally. If the blower cannot move air across the coil, heating and cooling performance can fall quickly and the system may protect itself. Filters and visible blockage are safe to check; motor and board diagnosis is professional work. Manual trigger: Indoor fan motor feedback signal is not emitted for 12 seconds while the fan motor operates.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the unit off, clean the indoor filter, and check only for obvious visible blockage at the air outlet. Restart once; if the blower does not run normally, stop troubleshooting.
When to call a pro
Call a licensed HVAC technician if the blower is noisy, stuck, or the code returns. Tell them the unit reported an indoor fan feedback fault.
View the fix ->

U3

U3 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The discharge temperature thermistor shorts or opens during compressor operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

U4

U4 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: An outdoor thermistor circuit is shorted or open.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

U6

U6 points to the power module or compressor winding short-circuit path. This is a serious compressor-drive fault, not a cleaning or settings issue. The system may refuse to run because continuing could damage expensive outdoor electronics. Manual trigger: The manual identifies power module abnormality or compressor winding short circuit.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

U8

U8 means the outdoor fan is not operating or reporting back the way the controls expect. Without the outdoor fan, the coil cannot move heat normally, so the system may shut down to protect itself. Keep leaves, snow, and debris away, but motor and board checks belong to a technician. Manual trigger: The outdoor fan motor is detected as abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn power off before looking at the outdoor fan area. Remove only obvious loose debris outside the grille, restore power once, and stop if the code returns or the fan does not start.
When to call a pro
Call a licensed HVAC technician if the fan is not visibly blocked, the fan blade is damaged, or the code returns. Tell them the Mitsubishi code identifies the outdoor fan motor circuit.
View the fix ->

UF

UF means the outdoor unit is protecting the compressor or inverter drive. Homeowner checks are limited because the expensive parts are inside the outdoor cabinet. If one reset does not hold, the compressor-drive circuit needs professional diagnosis. Manual trigger: The outdoor unit detects overcurrent, compressor synchronous abnormality, or start-up failure.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

UH

UH means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: Each phase current of the compressor cannot be detected normally.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

UJ

UJ means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: Abnormal DC bus-bar voltage is detected by the inverter system.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

UP

UP means the outdoor unit is protecting the compressor or inverter drive. Homeowner checks are limited because the expensive parts are inside the outdoor cabinet. If one reset does not hold, the compressor-drive circuit needs professional diagnosis. Manual trigger: Overcurrent protection cut-out operates 3 consecutive times within 1 minute after compressor start.

AdvisoryTechnician
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

P8

P8 means the system saw pipe temperature behavior that does not match normal operation. In homeowner terms, the indoor coil temperature is not changing the way the controls expect during heating or cooling. Filters and airflow are the safe checks; thermistor, refrigerant-flow, and inverter diagnosis belong to a technician. Manual trigger: The pipe-temperature abnormality protection is detected.

AdvisoryDIY part
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters. If the air-cleaning filter is packed with dust, tobacco tar, oil, or damage that cleaning will not remove, replace that user-serviceable filter before resetting once. Make sure louvers and return air are not blocked. Expected result: if airflow recovers, the code clears; if P8 returns, stop there.
When to call a pro
Call a licensed HVAC technician if P8 returns after filters and airflow are corrected or if the system still blows room-temperature air. Tell them P8 is a pipe-temperature abnormality and when it appears in the cycle.

Sourced homeowner part

Mitsubishi microparticle filter

View sourced part route
View the fix ->

U2

U2 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The discharge temperature exceeds 241F (116C) during compressor operation.

AdvisoryDIY
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

U5

U5 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The fin temperature protection threshold is exceeded during compressor operation.

AdvisoryDIY
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

U7

U7 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The discharge temperature is lower than the manual target condition.

AdvisoryDIY
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

UB

UB means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The outdoor P.C. board temperature protection threshold is exceeded during compressor operation.

AdvisoryDIY
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

UD

UD means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The outdoor unit enters high pressure protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
M-Series GX
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

MXZ-D Ported Multi-Zone

27 error codes / 5 catalog models tied to this line.

MXZ LED2 18

MXZ LED2 18 means an indoor-unit refrigerant sensor detected refrigerant. On an R454B MXZ-D system, this is a safety event, not a comfort nuisance. The system may run fan safety operation to dilute the space, and the next step is leak service.

Stop useTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Ventilate the room, avoid flames or spark sources, let any automatic fan safety operation run, and do not use normal heating or cooling. Expected result: people are protected while a qualified technician verifies the leak or sensor condition.
When to call a pro
Call a licensed HVAC technician before using the system normally. Tell them the exact Mitsubishi code and that it involves R454B refrigerant detection, leak sensing, or refrigerant-system abnormality.
View the fix ->

MXZ LED2 19

MXZ LED2 19 means the refrigerant leakage sensor is abnormal, disconnected, or has a broken wire. The system cannot rely on a required R454B leak-safety sensor. Treat it as stop-use until the sensor circuit is fixed and leakage is ruled out.

Stop useTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Ventilate the room, avoid flames or spark sources, let any automatic fan safety operation run, and do not use normal heating or cooling. Expected result: people are protected while a qualified technician verifies the leak or sensor condition.
When to call a pro
Call a licensed HVAC technician before using the system normally. Tell them the exact Mitsubishi code and that it involves R454B refrigerant detection, leak sensing, or refrigerant-system abnormality.
View the fix ->

MXZ LED2 20

MXZ LED2 20 means the MXZ-D outdoor unit sees an incompatible indoor/outdoor combination. This is a pairing problem, not a dirty filter or normal lockout. The equipment should not be run until compatibility is corrected. Manual trigger: The connected indoor/outdoor combination is incompatible.

Stop useTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off and do not keep testing modes or resets. Expected result: the compressor and electronics are protected until the installation or equipment mismatch is corrected.
When to call a pro
Call the installing contractor, Mitsubishi dealer, or licensed HVAC technician before running it again. Tell them the exact Mitsubishi stop-use code and whether installation or service happened recently.
View the fix ->

MXZ LED1 02

MXZ LED1 02 means the outdoor unit is protecting the compressor or inverter drive. Homeowner checks are limited because the expensive parts are inside the outdoor cabinet. If one reset does not hold, the compressor-drive circuit needs professional diagnosis. Manual trigger: The MXZ-D outdoor board indicates IPM or compressor lock protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

MXZ LED1 06

MXZ LED1 06 means the outdoor unit is protecting the compressor or inverter drive. Homeowner checks are limited because the expensive parts are inside the outdoor cabinet. If one reset does not hold, the compressor-drive circuit needs professional diagnosis. Manual trigger: The MXZ-D outdoor unit entered pre-heating protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

MXZ LED1 08

MXZ LED1 08 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The converter protection circuit is active.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED1 09

MXZ LED1 09 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The bus-bar voltage protection circuit is active.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED1 13

MXZ LED1 13 means the outdoor fan is not operating or reporting back the way the controls expect. Without the outdoor fan, the coil cannot move heat normally, so the system may shut down to protect itself. Keep leaves, snow, and debris away, but motor and board checks belong to a technician. Manual trigger: The outdoor fan motor is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn power off before looking at the outdoor fan area. Remove only obvious loose debris outside the grille, restore power once, and stop if the code returns or the fan does not start.
When to call a pro
Call a licensed HVAC technician if the fan is not visibly blocked, the fan blade is damaged, or the code returns. Tell them the Mitsubishi code identifies the outdoor fan motor circuit.
View the fix ->

MXZ LED1 14

MXZ LED1 14 means the outdoor unit did not confirm normal reversing-valve operation. That valve is what lets a heat pump switch between heating and cooling, so the symptom may look like poor heating, poor cooling, or room-temperature air. This is not a homeowner repair. Manual trigger: The MXZ-D outdoor unit detects abnormal 4-way valve switching operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and confirm all indoor heads are set to a compatible mode. Expected result: the fault clears; if heating and cooling still do not switch normally, stop there.
When to call a pro
Call a licensed HVAC technician if the code returns or the unit cannot change between heating and cooling. Tell them the code points to 4-way valve operation.
View the fix ->

MXZ LED2 01

MXZ LED2 01 means the indoor unit sees a drain, drain-sensor, or indoor valve signal problem. If water cannot leave the unit or a drain sensor cannot be trusted, the system may stop to prevent overflow or abnormal operation. Check for visible water or a blocked drain outlet only from outside the cabinet. Manual trigger: LED2 one blink indicates LEV and drain pump abnormality detected by an indoor unit.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
If you see water at the indoor head, turn the system off. Check only for an obvious blocked drain outlet or overflowing pan; if water is present or the code remains, leave it off.
When to call a pro
Call a licensed HVAC technician if water is present, the indoor head is dripping, or the code returns. Tell them the code points to the drain sensor, drain pump, or indoor LEV/drain circuit.
View the fix ->

MXZ LED2 02

MXZ LED2 02 means the outdoor unit is protecting the compressor or inverter drive. Homeowner checks are limited because the expensive parts are inside the outdoor cabinet. If one reset does not hold, the compressor-drive circuit needs professional diagnosis. Manual trigger: The MXZ-D outdoor board indicates an outdoor power-system abnormality.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off for 2 minutes, restore power once, and listen for normal startup. If the code returns, do not keep trying to force the compressor to start.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, the outdoor unit hums or clicks, or the breaker trips. Tell them the code is tied to compressor, IPM, inverter, or startup protection.
View the fix ->

MXZ LED2 03

MXZ LED2 03 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The discharge temperature thermistor is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

MXZ LED2 04

MXZ LED2 04 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The fin temperature thermistor or P.C. board temperature thermistor is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

MXZ LED2 05

MXZ LED2 05 means a temperature sensor reading does not make sense to the control board. The system uses those sensors to decide when to heat, cool, defrost, and protect itself, so it may stop even if the room feels normal. Filters and airflow are worth checking, but sensor circuits are technician work. Manual trigger: The ambient, outdoor heat exchanger, or defrost thermistor is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and make sure the indoor filter and nearby airflow are not obviously blocked. Expected result: a temporary sensor fault clears; if the same code returns, the sensor circuit needs service.
When to call a pro
Call a licensed HVAC technician if the code comes back after one reset or the unit will not heat or cool normally. Tell them which thermistor-related Mitsubishi code is displayed.
View the fix ->

MXZ LED2 07

MXZ LED2 07 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The outdoor control system cannot read nonvolatile memory data properly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 08

MXZ LED2 08 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The current sensor is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 11

MXZ LED2 11 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: Communication between P.C. boards or the M-NET adapter is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.

Technician part context

Mitsubishi M-NET Interface for MXZ

View sourced part route
View the fix ->

MXZ LED2 12

MXZ LED2 12 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The zero-cross detecting circuit is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 13

MXZ LED2 13 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The input-current detection circuit is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 14

MXZ LED2 14 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: The input-voltage detection circuit is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 15

MXZ LED2 15 means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: Relay operation is not detected normally.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
View the fix ->

MXZ LED2 21

MXZ LED2 21 means the outdoor unit did not confirm normal reversing-valve operation. That valve is what lets a heat pump switch between heating and cooling, so the symptom may look like poor heating, poor cooling, or room-temperature air. This is not a homeowner repair. Manual trigger: The 4-way valve is detected abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Power cycle once and confirm all indoor heads are set to a compatible mode. Expected result: the fault clears; if heating and cooling still do not switch normally, stop there.
When to call a pro
Call a licensed HVAC technician if the code returns or the unit cannot change between heating and cooling. Tell them the code points to 4-way valve operation.
View the fix ->

MXZ LED2 24

MXZ LED2 24 means the indoor and outdoor controls are not exchanging a signal the system can trust. That can be a simple power-handshake problem, but repeated communication faults usually point to wiring, connectors, or a control board. One reset is reasonable; repeated resets are not a fix. Manual trigger: Serial signal communication between indoor and outdoor units is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Turn the system off, switch the breaker or disconnect off for 2 minutes, then restore power and call for one mode only. Expected result: the code clears and the indoor and outdoor units start normally; if it returns, stop resetting.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset, either unit remains dead, or a breaker trips. Tell them the exact Mitsubishi code and that it points to a serial/control communication path.
View the fix ->

MXZ LED1 03

MXZ LED1 03 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The MXZ-D outdoor unit entered discharge temperature protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

MXZ LED1 04

MXZ LED1 04 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The MXZ-D outdoor unit entered fin or P.C. board temperature protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

MXZ LED1 05

MXZ LED1 05 means the system hit a temperature or pressure protection limit. That often means the unit is trying to protect the compressor rather than keep forcing operation. Dirty filters, blocked airflow, outdoor obstruction, weather, or refrigerant-flow problems can be involved. Manual trigger: The MXZ-D outdoor unit entered high pressure protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Clean the indoor filters, clear leaves or snow around the outdoor unit, confirm supply and return air are not blocked, then reset once. Expected result: the protection clears and does not return during the next heating or cooling call.
When to call a pro
Call a licensed HVAC technician if the code returns after filters and airflow are corrected, or if cooling/heating is weak. Tell them the code appeared with a temperature or pressure protection condition.
View the fix ->

MXZ LED1 11

MXZ LED1 11 means low outside-temperature protection stopped the outdoor unit. This can be a normal protection response when conditions are outside the unit operating envelope. If outdoor temperature is within the published operating range and it still appears, sensors or controls need service.

AdvisoryDIY
Sourced Jul 2026
Applies to
MXZ-D Ported Multi-Zone
Homeowner fix
Confirm the outdoor unit is not buried in snow or ice and wait for outdoor temperature to move back within operating range. Do not force emergency operation repeatedly.
When to call a pro
Call a licensed HVAC technician if the code appears when outdoor temperature is within the published range or the unit cannot heat in normal conditions. Tell them the MXZ-D is showing low outside-temperature protection.
View the fix ->