Mitsubishi Electric / M-Series GX
Mitsubishi Electric UH error code
UH means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: Each phase current of the compressor cannot be detected normally.
- Urgency
- advisory
- Verified
- Jul 30, 2026
- Fix path
- Technician
What it means
UH means a control-board memory, voltage, or feedback signal is outside the normal range. That does not tell a homeowner which board is bad; it tells you the controls are no longer confident enough to run normally. Treat a repeat code as a service diagnosis. Manual trigger: Each phase current of the compressor cannot be detected normally.
Urgency
advisory
This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.
Likely causes
- Brief power event, brownout, or unstable supply voltage
- Loose power connection, reactor, or outdoor electrical component problem
- Inverter/IPM protection or current-detection fault
- Compressor winding, drive, or outdoor board fault after power checks pass
Homeowner fix
Power cycle once and note any storm, brownout, generator, or recent electrical work. Expected result: a one-time control fault clears; if it returns, do not open the cabinet.
When to call a pro
Call a licensed HVAC technician if the code returns after one reset or you suspect a supply-voltage problem. Tell them the Mitsubishi code points to a board, relay, current, voltage, or converter circuit.
This code points to compressor and electrical or inverter work - get repair quotes from contractors in your area.
Get repair quotesRepair vs replace
This can be a control-board repair, which is not automatically a replacement signal. Compare the quote with replacement if the unit is older, out of warranty, or has repeated board failures.
See Mitsubishi Electric mini-splitsYour Mitsubishi Electric model
M-Series GX model pages in the Mitsubishi Electric catalog help compare this repair path with current replacement options.
- Mitsubishi Electric M-Series GX 9,000 BTU R-454B 208/230V (MSZ-GX09NL / MUZ-GX09NL)
M-Series GX
- Mitsubishi Electric M-Series GX Hyper-Heat 9,000 BTU R-454B 208/230V (MSZ-GX09NL / MUZ-GX09NLHZ)
M-Series GX
- Mitsubishi Electric M-Series GX 12,000 BTU R-454B 208/230V (MSZ-GX12NL / MUZ-GX12NL)
M-Series GX
- Mitsubishi Electric M-Series GX Hyper-Heat 12,000 BTU R-454B 208/230V (MSZ-GX12NL / MUZ-GX12NLHZ)
M-Series GX
Parts for this line
The parts catalog for Mitsubishi Electric M-Series GX lists 6 sourced replacement parts for this product line.
Open parts pageFor your technician
Technician note: verify incoming power, connectors, and the named P.C. board circuit before board replacement. Page context: Mitsubishi Electric maps this display to the M-Series GX line; source: Mitsubishi Electric MSZ-GX/MUZ-GX R454B service manuals; display convention: match the letter U and letter H marker exactly before comparing neighboring codes.
Which systems show it
- Mitsubishi Electric M-Series R454B wall-mount outdoor units covered by MUZ-GX OBH951C and cross-checked against MUZ-FX OBH946C and MUZ-WX OBH955A.
Related troubleshooting
Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.
Reset note
After the documented cause is corrected, operate the unit and confirm the failure-mode recall/error-code display returns to 00.
Manual trigger
Each phase current of the compressor cannot be detected normally.
Related codes
Source
- Section
- 11-2 Outdoor unit failure mode recall function
- Page
- 61
Short quote: "Each phase current of compressor cannot be detected normally."
Sourced Jul 2026