SplitAtlas

MRCOOL / DIY 5th Generation

PC 04 error code

The manual describes abnormal inverter compressor drive involving communication signal, voltage, or compressor rotation-speed detection.

Severity
technician
Verified
Jul 18, 2026

What triggers it

The manual describes abnormal inverter compressor drive involving communication signal, voltage, or compressor rotation-speed detection.

What to do

  1. Check wiring between the outdoor PCB and compressor; correct or replace wires and connectors if faulty.
  2. Check IPM installation; tighten screws and apply silicon grease if installation is not correct.
  3. Perform the manual's IPM continuity check; replace the IPM board or outdoor PCB when terminal resistance is not uniform.
  4. Check outdoor fan operation and outdoor ventilation; use the fan-speed troubleshooting procedure if needed.
  5. Measure compressor resistance; replace the compressor if resistance is not uniform, otherwise replace the outdoor PCB.

Which systems show it

  • MRCOOL DIY 5th Generation single-zone 9k, 12k, 18k, 24k, and 36k D25 indoor/outdoor models listed in manual section 1.1.

Related codes

Technician scope

Compressor, IPM, outdoor PCB

Source

MRCOOL R454B DIY-5 service manual
Document
data/sources/mrcool-diy5-service.pdf
Section
4.7 TS12-S: Inverter compressor drive error diagnosis and solution
Page
73
Verified Jul 2026

Next step