ACiQ EHC1 error code

EHC1 is a refrigerant leak alarm from the indoor refrigerant sensor. Because the system uses R-454B A2L refrigerant, treat this as a stop-use safety event.

Urgency
stop use
Verified
Jul 30, 2026
Fix path
Technician

What it means

EHC1 is a refrigerant leak alarm from the indoor refrigerant sensor. Because the system uses R-454B A2L refrigerant, treat this as a stop-use safety event.

Urgency

Likely causes

  1. Actual refrigerant leak at a flare joint, coil, line set, or service connection
  2. Low refrigerant charge or charge loss after installation or service
  3. Refrigerant sensor, T1/T2, or related control input reading abnormally
  4. Indoor or outdoor board fault only after the leak and sensor checks pass

Homeowner fix

Turn the system off, ventilate the space, avoid flames, sparks, and smoking, and do not reset the unit back into normal operation. Expected result: the system stays off until a licensed technician verifies the leak sensor and refrigerant circuit.

When to call a pro

Call a licensed HVAC technician immediately. Tell them the display is EHC1 and the manual says the refrigerant sensor detected leakage.

This code points to refrigerant or sealed-system work - get repair quotes from contractors in your area.

Get repair quotes

Repair vs replace

A leak-sensor replacement or minor leak repair may be reasonable, especially under warranty. If the repair involves a coil, buried line set, or repeated refrigerant loss, compare the quote with replacement.

See ACiQ mini-splits

Your ACiQ model

Multi-Zone Extreme Series model pages in the ACiQ catalog help compare this repair path with current replacement options.

For your technician

Technician note: follow R-454B/A2L leak-safety procedures, ventilate and verify the area, locate any leak, repair before recharge, and verify the sensor. Page context: ACiQ maps this display to the Multi-Zone Extreme Series line; source: ACiQ Multi-Zone Service Manual and shared Midea D5CMRA Table 20 display reference; display convention: match the letter E, letter H, letter C, and one marker exactly before comparing neighboring codes.

Which systems show it

  • ACiQ Multi-Zone Extreme Series R-454B systems using the shared Midea/ACiQ multi-zone platform.
  • ACiQ Multi-Zone Standard Series R-454B systems where the ACiQ service manual lists the same EC/EH/EL/PC diagnostics.
  • ACiQ wall-mounted, cassette, duct, console, and AHU indoor units listed in service manual section 7.2.

Sold under more than one brand

Shared with Midea. ACiQ and Midea document this code from the same manufacturer source, so EHC1 means the same thing on either badge and the steps above apply.

Open Midea EHC1

Related troubleshooting

Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.

Reset note

Turn the system off, ventilate the space, avoid flames, sparks, and smoking, and do not reset the unit back into normal operation. Expected result: the system stays off until a licensed technician verifies the leak sensor and refrigerant circuit.

Manual trigger

EHC1 is a refrigerant leak alarm from the indoor refrigerant sensor. Because the system uses R-454B A2L refrigerant, treat this as a stop-use safety event.

Related codes

Source

ACiQ Multi-Zone Service Manual; Midea D5CMRA Installation Instructions
Section
Midea Table 20; Midea leak detection system warning; ACiQ service manual section 7.4.1.13
Page
Midea PDF page 37; Midea PDF pages 4-6; ACiQ PDF page 62; ACiQ PDF page 81

Short quote: "Refrigerant sensor detects leakage."

Sourced Jul 2026

Next step