GREE / Livo R32
GREE PF error code
PF means the controls are not getting a believable reading from the drive-board ambient temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.
- Urgency
- advisory
- Verified
- Jul 30, 2026
- Fix path
- Technician
What it means
PF means the controls are not getting a believable reading from the drive-board ambient temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.
Urgency
advisory
This is not usually an immediate safety hazard, but do not keep resetting it. Try the safe homeowner check below; if the code comes back, schedule service.
Likely causes
- Brief power event, brownout, or unstable supply voltage
- Loose power connection, reactor, or outdoor electrical component problem
- Inverter/IPM protection or current-detection fault
- Compressor winding, drive, or outdoor board fault after power checks pass
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if PF returns. Tell them the GREE manual identifies the drive-board ambient temperature sensor sensor circuit.
This code points to refrigerant or sealed-system, compressor, and electrical or inverter work - get repair quotes from contractors in your area.
Get repair quotesRepair vs replace
This is normally repairable, but it is not a homeowner repair. If the unit is older, out of warranty, or a technician quotes a major compressor, inverter, or sealed-system repair, compare that quote with replacement before approving it.
See GREE mini-splitsYour GREE model
Livo R32 model pages in the GREE catalog help compare this repair path with current replacement options.
Parts for this line
The parts catalog for GREE Livo R32 lists 8 sourced replacement parts for this product line.
Open parts pageFor your technician
Technician note: check drive-board ambient temperature sensor resistance, routing, connector condition, seating, and the related board input before replacing controls. Page context: GREE maps this display to the Livo R32 line; source: GREE R32 residential mini-split service manuals; display convention: match the letter P and letter F marker exactly before comparing neighboring codes.
Which systems show it
- GREE LIVO R32 wall-mounted single-zone systems.
- GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.
- GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Related troubleshooting
Use the symptom guide alongside the exact display code if the unit is flashing, cycling, or showing comfort symptoms.
Reset note
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
Manual trigger
PF means the drive-board ambient temperature sensor sensor circuit is open or shorted.
Related codes
Source
- Section
- Troubleshooting - Error Code List
- Page
- 61 (PDF page 64)
Short quote: "Ambient temperature sensor of drive board."
Sourced Jul 2026