SplitAtlas

Error-code hub

GREE error codes

GREE shows faults as an alphanumeric code on the indoor display, and the same set runs across Livo, Vireo, Envo, Sapphire and Zeno. The 52 codes below come from GREE service manuals. Because GREE manufactures for several other badges, these codes also appear - sometimes verbatim - on Cosmo and TOSOT systems, which have their own pages here.

Status displays
5
Error codes
52

Unit applicability

Match your unit before reading the table

This table is sourced for Livo R32. If your unit is a different generation or product line not named here, the same display code may vary by generation.

Common codes first

Most broadly applicable documented codes

Ranking basis: we do not have failure-frequency telemetry. These are ordered by breadth of affected systems in the SplitAtlas catalog - the documented product line's published model count, whether the same code appears on more than one product line, and any manual applicability notes we hold. This is a breadth ranking, not a popularity claim.

B5

B5 means the controls are not getting a believable reading from the liquid valve temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
View the fix
B7

B7 means the controls are not getting a believable reading from the gas valve temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
View the fix
C4

C4 means the outdoor control board is not reading its configuration jumper correctly. That jumper identifies unit configuration to the control board, so the outdoor unit may lock out until it is corrected. Manual trigger: C4 means the outdoor unit jumper cap is missing or not being read.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
View the fix
C5

C5 means a small configuration jumper that tells the indoor control board what unit it is serving is missing, loose, damaged, or not being read. For a homeowner, this usually appears after installation or service and is not a setting to adjust from the remote. Manual trigger: C5 means the indoor unit reports a jumper-cap fault.

AdvisoryTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
View the fix
E1

E1 means refrigerant pressure rose higher than the controls allow. The most homeowner-relevant cause is poor outdoor airflow, but overcharge, restrictions, fan faults, and pressure-switch issues also belong on the technician list. Manual trigger: E1 means the system has gone into high-pressure protection.

AdvisoryDIY
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
View the fix
E3

E3 means the refrigerant side is reading too low or the low-pressure protection circuit is open. On current GREE R32 systems, that can be consistent with a refrigerant leak and should not be treated as a normal reset code. Manual trigger: E3 means the system detected low-pressure protection.

Stop useTechnician
Breadth evidence
12 published catalog models on its documented product line. Manual applicability notes: GREE LIVO R32 wall-mounted single-zone systems.; GREE VIREO R32, ENVO R32, and Sapphire R32 wall-mounted single-zone systems using the common GREE R32 high-wall diagnostic table.; GREE Free Match/Multi R32 and Free Match ECO/Multi ECO R32 systems when the connected indoor unit uses this common GREE indoor display table; GREE notes that multi-zone codes can differ by indoor unit type.
Safe first check
Stop normal heating or cooling, ventilate the room, avoid flames or spark sources, and do not keep resetting the system. Expected result: operation remains stopped until a licensed technician verifies the refrigerant condition.
View the fix

Safe first checks

Checks you can do without opening the unit

These codes have homeowner-safe steps such as filters, airflow, condensate/drain checks, remote/controller items, or a single safe power reset. If the code returns, stop at the boundary in the card.

E8DIY part

Clean the washable filters. If a filter is damaged or packed with debris that will not rinse out, replace it with the exact filter for your indoor model, then reset once. Expected result: airflow improves and E8 clears; if it returns, stop there.

Sourced homeowner part

Indoor washable filter assembly

View sourced part route
Read the full code guide
B5Technician

Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.

Read the full code guide
B7Technician

Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.

Read the full code guide
C4Technician

Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.

Read the full code guide

GREE mini-splits

Use the GREE catalog to connect these manual error codes to current model pages and replacement options.

Status displays

CL

CL means the indoor unit is running its Auto Clean drying cycle. It is trying to dry the indoor coil after operation, not reporting a fault.

Not an error
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Let the cycle finish. If you turned Auto Clean on by accident, cancel it from the remote and return the unit to normal operation.
Status note
This is a normal status indication, not an error, unless comfort is poor, water is present, or the indication never clears.
View the fix ->

E2

E2 means the unit is protecting the indoor coil from freezing during cooling. The GREE service table identifies it as a status code in the cooling process, not a fault by itself.

Not an error
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, make sure return air and supply air are not blocked, and let the coil thaw. Expected result: normal cooling resumes when coil temperature recovers.
Status note
This is a normal status indication, not an error, unless comfort is poor, water is present, or the indication never clears.
View the fix ->

E9

E9 means the indoor fan is being delayed or limited so the unit does not blow cold air during heating. On these current GREE R32 high-wall service tables it is labeled as a status code, not an error.

Not an error
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Wait several minutes for the indoor coil to warm up. If water is present, the unit has a factory condensate pump, or the display persists with no heat, stop normal operation and call for service.
Status note
This is a normal status indication, not an error, unless comfort is poor, water is present, or the indication never clears.
View the fix ->

FO

FO means the unit is in refrigerant-recovery or pump-down mode. The GREE service manual describes this as a maintenance mode, not a normal homeowner error display.

Not an error
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
If a technician intentionally placed the unit in this mode, let them finish. If FO appeared unexpectedly, turn the system off from the remote and call the installer before running normal heating or cooling.
Status note
This is a normal status indication, not an error, unless comfort is poor, water is present, or the indication never clears.
View the fix ->

H1

H1 means the heat pump is in defrost or oil-return operation during heating. The outdoor unit may steam, the indoor fan may pause, and heating should resume after the cycle finishes.

Not an error
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Let the defrost or oil-return cycle finish. Keep the outdoor unit clear of snow and ice buildup around the base, but do not chip ice from the coil.
Status note
This is a normal status indication, not an error, unless comfort is poor, water is present, or the indication never clears.
View the fix ->

All error codes

E3

E3 means the refrigerant side is reading too low or the low-pressure protection circuit is open. On current GREE R32 systems, that can be consistent with a refrigerant leak and should not be treated as a normal reset code. Manual trigger: E3 means the system detected low-pressure protection.

Stop useTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Stop normal heating or cooling, ventilate the room, avoid flames or spark sources, and do not keep resetting the system. Expected result: operation remains stopped until a licensed technician verifies the refrigerant condition.
When to call a pro
Call a licensed HVAC technician before using the system normally again. Tell them the display is GREE E3 on an R32 system.
View the fix ->

EA

EA means the air conditioner may have detected a refrigerant leak condition. On current GREE R32 systems, treat this as a stop-use safety code until a licensed technician verifies the space and the refrigerant circuit. Manual trigger: EA means the unit is alarming for possible refrigerant leakage.

Stop useTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Stop normal heating or cooling, ventilate the room, avoid flames or spark sources, and do not keep resetting the system. Expected result: operation remains stopped until a licensed technician verifies the refrigerant condition.
When to call a pro
Call a licensed HVAC technician before using the system normally again. Tell them the display is GREE EA on an R32 system.
View the fix ->

F0

F0 means the control logic thinks refrigerant flow or charge is not adequate. On current GREE R32 systems, treat this as a possible refrigerant leak or sealed-system problem, not a code to keep clearing from the remote. Manual trigger: F0 means the system detected insufficient refrigerant or refrigerant-flow cut-off protection.

Stop useTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Stop normal heating or cooling, ventilate the room, avoid flames or spark sources, and do not keep resetting the system. Expected result: operation remains stopped until a licensed technician verifies the refrigerant condition.
When to call a pro
Call a licensed HVAC technician before using the system normally again. Tell them the display is GREE F0 on an R32 system.
View the fix ->

B5

B5 means the controls are not getting a believable reading from the liquid valve temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if B5 returns. Tell them the GREE manual identifies the liquid valve temperature sensor sensor circuit.
View the fix ->

B7

B7 means the controls are not getting a believable reading from the gas valve temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if B7 returns. Tell them the GREE manual identifies the gas valve temperature sensor sensor circuit.
View the fix ->

C4

C4 means the outdoor control board is not reading its configuration jumper correctly. That jumper identifies unit configuration to the control board, so the outdoor unit may lock out until it is corrected. Manual trigger: C4 means the outdoor unit jumper cap is missing or not being read.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if C4 returns after one reset or appears after installation/service. Tell them the manual calls out the outdoor jumper cap.
View the fix ->

C5

C5 means a small configuration jumper that tells the indoor control board what unit it is serving is missing, loose, damaged, or not being read. For a homeowner, this usually appears after installation or service and is not a setting to adjust from the remote. Manual trigger: C5 means the indoor unit reports a jumper-cap fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if C5 returns after one reset or appears right after installation. Tell them the manual points to the indoor jumper cap circuit.
View the fix ->

E4

E4 means the compressor is running hot at the discharge line. Dirty filters or blocked outdoor airflow can contribute, but repeated E4 faults often need refrigerant-circuit and compressor checks. Manual trigger: E4 means the compressor discharge temperature is too high.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if E4 returns after filters and outdoor clearance are corrected. Tell them the code is compressor high discharge temperature.
View the fix ->

E6

E6 means the indoor unit and outdoor unit are not exchanging control signals reliably. The system may stop heating or cooling even though the remote still works, because the two halves of the heat pump cannot coordinate safely. Manual trigger: E6 means the indoor and outdoor units are not communicating normally.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if E6 returns after one reset, appears on a new installation, or more than one indoor head is affected. Tell them the code is indoor/outdoor communication.
View the fix ->

EE

EE means the outdoor control board memory data is not being read or stored correctly. This is not a thermostat setting or filter issue; the outdoor controls need technician diagnosis. Manual trigger: EE means the outdoor unit reports an EEPROM memory fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EE returns. Tell them the code is outdoor EEPROM malfunction.
View the fix ->

F1

F1 means the controls are not getting a believable reading from the indoor room-air temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F1 returns. Tell them the GREE manual identifies the indoor room-air temperature sensor sensor circuit.
View the fix ->

F2

F2 means the controls are not getting a believable reading from the indoor evaporator temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F2 returns. Tell them the GREE manual identifies the indoor evaporator temperature sensor sensor circuit.
View the fix ->

F3

F3 means the controls are not getting a believable reading from the outdoor ambient temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F3 returns. Tell them the GREE manual identifies the outdoor ambient temperature sensor sensor circuit.
View the fix ->

F4

F4 means the controls are not getting a believable reading from the outdoor condenser temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F4 returns. Tell them the GREE manual identifies the outdoor condenser temperature sensor sensor circuit.
View the fix ->

F5

F5 means the controls are not getting a believable reading from the compressor discharge temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if F5 returns. Tell them the GREE manual identifies the compressor discharge temperature sensor sensor circuit.
View the fix ->

H3

H3 means the compressor is running too hot or under too much load and the overload protection has stepped in. Airflow problems can contribute, but repeated H3 faults can point to compressor, refrigerant-circuit, or protection-device issues. Manual trigger: H3 means the compressor overload protection has opened.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if H3 returns after filters and outdoor clearance are corrected. Tell them the code is compressor overload protection.
View the fix ->

H5

H5 means the outdoor inverter power module protected itself from an abnormal compressor-drive condition. A blocked outdoor coil can contribute, but the protected components are inside the outdoor cabinet and are not homeowner-serviceable. Manual trigger: H5 means the inverter module has gone into IPM protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clear leaves, snow, or loose debris from around the outdoor unit without removing panels, then reset power once. Expected result: an airflow-related nuisance trip clears; if H5 returns, stop using the unit.
When to call a pro
Call a licensed HVAC technician if H5 returns or the outdoor unit will not start. Tell them the code is IPM protection.
View the fix ->

H6

H6 means the indoor blower is not proving operation to the control board. The indoor head may be powered, but without reliable blower feedback it cannot move air across the coil safely. Manual trigger: H6 means the indoor fan motor is not giving normal feedback.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the unit off and make sure the front filter area is clean and not visibly blocked. Do not reach into the blower wheel. Restore power once; if H6 returns or the blower does not start, stop there.
When to call a pro
Call a licensed HVAC technician if the indoor fan does not run or H6 returns. Tell them the code is no indoor fan motor feedback.
View the fix ->

H7

H7 means the inverter drive lost normal synchronization with the compressor. The unit may try to start and then stop because the compressor is not following the drive signal as expected.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the unit off and reset power once. Expected result: a one-time startup fault clears; if H7 returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if H7 returns or the outdoor unit repeatedly tries and fails to start. Tell them the code is compressor desynchronizing.
View the fix ->

HC

HC means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: HC means the outdoor unit detected PFC protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if HC returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to PFC protection.
View the fix ->

HE

HE means the inverter drive detected a compressor-motor protection condition. This is a serious drive/compressor diagnostic, not a homeowner repair. Manual trigger: HE means compressor demagnetization protection is active.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off and reset power once. Expected result: a one-time event clears; if HE returns, leave the unit off and schedule service.
When to call a pro
Call a licensed HVAC technician if HE returns or the outdoor unit cannot start. Tell them the code is compressor demagnetizing protection.
View the fix ->

JF

JF means the indoor unit is not communicating normally with the inspection or display board referenced by the manual. Comfort may still seem normal, but the fault should be documented if it persists. Manual trigger: JF means communication with the inspection board is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
If the system is otherwise operating normally, write down JF and reset power once. Expected result: a temporary display-board fault clears; if it returns, schedule service.
When to call a pro
Call a licensed HVAC technician if JF returns, the display behaves oddly, or controls stop responding. Tell them the manual says indoor-to-inspection-board communication.
View the fix ->

L1

L1 means the controls are not getting a believable reading from the humidity sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if L1 returns. Tell them the GREE manual identifies the humidity sensor sensor circuit.
View the fix ->

L3

L3 means the outdoor unit is not getting the fan operation it expects from outdoor fan 1. Without that fan, the outdoor coil cannot reject or absorb heat normally, so the unit protects itself. Manual trigger: L3 means outdoor fan 1 is not operating or reporting normally.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the unit off before looking at the outdoor fan area. Remove only loose debris outside the grille, restore power once, and stop if the fan still does not start or L3 returns.
When to call a pro
Call a licensed HVAC technician if the fan is not visibly blocked, the blade is damaged, or L3 returns. Tell them the code is outdoor fan 1.
View the fix ->

LA

LA means the outdoor unit is not getting the fan operation it expects from outdoor fan 2. On dual-fan outdoor units, that second fan is needed for normal heat transfer and protection. Manual trigger: LA means outdoor fan 2 is not operating or reporting normally on dual-fan models.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the unit off before looking at the outdoor fan area. Remove only loose debris outside the grille, restore power once, and stop if the fan still does not start or LA returns.
When to call a pro
Call a licensed HVAC technician if LA returns or either outdoor fan is not running freely. Tell them the code is outdoor fan 2 on a dual-fan unit.
View the fix ->

LC

LC means the outdoor unit tried to start the compressor and could not complete a normal start. That can be a drive, compressor, voltage, or load problem and should not be repeatedly reset. Manual trigger: LC means compressor start-up failed.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off for several minutes and reset power once. Expected result: a one-time start fault clears; if LC returns, leave the unit off and call for service.
When to call a pro
Call a licensed HVAC technician if LC returns or the outdoor unit repeatedly attempts to start. Tell them the code is compressor start-up failure.
View the fix ->

LD

LD means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: LD means the outdoor unit detected compressor phase loss.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if LD returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to compressor phase loss.
View the fix ->

LP

LP means the system thinks the connected indoor and outdoor equipment do not match correctly. This is usually an installation, pairing, or configuration issue rather than something a homeowner can fix from the remote. Manual trigger: LP means the matched indoor/outdoor capacity or unit combination is not accepted.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Write down all indoor and outdoor model numbers and reset power once. Expected result: if it was a temporary commissioning fault it clears; if LP returns, the equipment match must be checked by the installer.
When to call a pro
Call the installer or a licensed HVAC technician if LP appears after installation, service, or adding a zone. Tell them the manual points to matched capacity or model combination.
View the fix ->

OE

OE is a broad outdoor-unit fault. The manual points to outdoor operating range, compressor wiring/startup, compressor damage, or main-board damage, so it is best treated as a service code after one safe reset. Manual trigger: OE means the outdoor unit is reporting an undefined outdoor fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
If outdoor weather is extreme, turn the system off and wait for conditions to move back into the normal range, then reset once. If OE returns in normal conditions, stop there.
When to call a pro
Call a licensed HVAC technician if OE returns, appears in normal outdoor temperatures, or the outdoor unit will not start. Tell them it is an undefined outdoor-unit error.
View the fix ->

P5

P5 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: P5 means the outdoor unit detected compressor over-phase current protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if P5 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to compressor over-phase current protection.
View the fix ->

P6

P6 means the outdoor unit has an internal communication problem between its main control board and drive board. This is inside the outdoor cabinet and requires technician diagnosis.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if P6 returns after one reset. Tell them the code is communication between the drive board and main board.
View the fix ->

P7

P7 means the controls are not getting a believable reading from the module temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if P7 returns. Tell them the GREE manual identifies the module temperature sensor sensor circuit.
View the fix ->

PF

PF means the controls are not getting a believable reading from the drive-board ambient temperature sensor. The unit may stop because it cannot safely judge room, coil, valve, or discharge temperature from that input. Sensor circuits are technician work.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if PF returns. Tell them the GREE manual identifies the drive-board ambient temperature sensor sensor circuit.
View the fix ->

PH

PH means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: PH means the outdoor unit detected DC bus voltage that is too high.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if PH returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to DC bus voltage that is too high.
View the fix ->

PL

PL means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: PL means the outdoor unit detected DC bus voltage that is too low.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if PL returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to DC bus voltage that is too low.
View the fix ->

PU

PU means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: PU means the outdoor unit detected capacitor charging malfunction.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if PU returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to capacitor charging malfunction.
View the fix ->

RF

RF means the wireless/RF module used by the control system is not operating normally. It may affect accessory or communication features rather than the refrigerant system itself, but it still requires service if it persists. Manual trigger: RF means the RF module is malfunctioning.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off at the remote, then power cycle once at the breaker if you can do that safely. Expected result: a temporary control fault clears; if the same code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if RF returns or wireless/control features do not work. Tell them the code is RF module malfunction.
View the fix ->

U1

U1 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: U1 means the outdoor unit detected phase-current detection circuit malfunction.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if U1 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to phase-current detection circuit malfunction.
View the fix ->

U2

U2 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: U2 means the outdoor unit detected compressor phase-loss protection.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if U2 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to compressor phase-loss protection.
View the fix ->

U3

U3 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: U3 means the outdoor unit detected DC bus voltage drop.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if U3 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to DC bus voltage drop.
View the fix ->

U5

U5 means the outdoor control system is seeing current detection that does not make sense. The manual also points to low refrigerant as a possible condition, so this belongs with a licensed technician rather than repeated resets. Manual trigger: U5 means the unit current-detection circuit is abnormal.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off and reset power once. Expected result: a temporary control reading clears; if U5 returns, stop running the unit and schedule service.
When to call a pro
Call a licensed HVAC technician if U5 returns or cooling/heating is weak. Tell them the manual links U5 to current detection and possible low refrigerant.
View the fix ->

U7

U7 means the heat pump did not confirm normal reversing-valve operation. That valve changes the system between heating and cooling, so symptoms may include poor heating, poor cooling, or room-temperature air. Manual trigger: U7 means the 4-way reversing valve is not operating normally.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Set all indoor heads to the same mode, turn the system off, and reset power once. Expected result: a temporary mode or switching issue clears; if U7 returns, stop there.
When to call a pro
Call a licensed HVAC technician if U7 returns or the unit cannot switch between heating and cooling. Tell them the code is 4-way valve abnormal.
View the fix ->

U8

U8 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: U8 means the outdoor unit detected an indoor-unit zero-crossing signal fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if U8 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to an indoor-unit zero-crossing signal fault.
View the fix ->

U9

U9 means the inverter or power-detection section saw an abnormal electrical condition and protected the unit. Homeowners should not open the outdoor cabinet or test live components; write down the code and arrange service if one reset does not clear it. Manual trigger: U9 means the outdoor unit detected an outdoor-unit zero-crossing fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the system off, wait several minutes, and reset power once if you can do so safely. Expected result: a brief utility disturbance clears; if the code returns, leave the system off and call for service.
When to call a pro
Call a licensed HVAC technician if U9 returns, the breaker trips, or the outdoor unit will not start. Tell them the code points to an outdoor-unit zero-crossing fault.
View the fix ->

E1

E1 means refrigerant pressure rose higher than the controls allow. The most homeowner-relevant cause is poor outdoor airflow, but overcharge, restrictions, fan faults, and pressure-switch issues also belong on the technician list. Manual trigger: E1 means the system has gone into high-pressure protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if E1 returns after airflow is corrected, if the outdoor fan is not running, or if the unit trips quickly. Tell them the code is high-pressure protection.
View the fix ->

E5

E5 means the system pulled more current than allowed or the drive saw a high-load condition. The homeowner-safe checks are airflow and one reset; repeated E5 faults require electrical and compressor diagnosis by a technician. Manual trigger: E5 means the unit detected over-current protection.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if E5 returns, the breaker trips, or the system struggles to start. Tell them the code is over-current protection.
View the fix ->

E7

E7 usually means indoor heads on the same outdoor unit are asking for incompatible modes, such as one room calling for cooling while another calls for heating. The outdoor unit cannot heat and cool different zones at the same time. Manual trigger: E7 means a multi-zone system has a mode conflict.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Set every indoor head on that outdoor unit to the same mode, or turn unused heads off. Wait several minutes, then restart the system. Expected result: E7 clears once all zones request compatible operation.
When to call a pro
Call a licensed HVAC technician if E7 returns when all indoor heads are set to the same mode or if one zone will not change mode. Tell them it appears as a GREE mode conflict.
View the fix ->

E8

E8 means the unit is limiting or stopping operation because temperatures are getting too high during the cycle. For a homeowner, the first useful check is airflow: a dirty filter, blocked return, or blocked outlet can make the indoor coil run outside the expected range. Manual trigger: E8 means high-temperature prevention protection is active.

AdvisoryDIY part
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the washable filters. If a filter is damaged or packed with debris that will not rinse out, replace it with the exact filter for your indoor model, then reset once. Expected result: airflow improves and E8 clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if E8 returns after filters and airflow are corrected, or if the indoor fan does not move air normally. Tell them the code is high-temperature prevention protection.

Sourced homeowner part

Indoor washable filter assembly

View sourced part route
View the fix ->

FC

FC means a safety or position micro-switch is not proving the expected state. Depending on the indoor model, a cover, panel, or service switch may not be seated, or the switch circuit may have failed. Manual trigger: FC means the unit reports a micro-switch malfunction.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Turn the unit off, make sure the front panel and filter cover are fully latched, then reset power once. Expected result: if a cover was not seated, FC clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if FC returns after the covers are seated or if any switch or wiring is damaged. Tell them the code is a micro-switch malfunction.
View the fix ->

H4

H4 is a broad system-abnormal protection code. The manuals group it with overload, high tube temperature, high protection, and poor outdoor air circulation, so start with airflow and then treat repeats as a technician diagnosis. Manual trigger: H4 means the system has detected an abnormal operating condition.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if H4 returns after filters and outdoor clearance are corrected. Tell them H4 is a broad GREE system abnormal protection code.
View the fix ->

L9

L9 means the unit is limiting or stopping because operating load is too high. Airflow and outdoor clearance are the safe homeowner checks; repeated L9 faults need load, refrigerant, and drive checks. Manual trigger: L9 means high-power protection is active.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clean the indoor filters, keep return and supply air paths open, and clear leaves, snow, or loose debris from around the outdoor unit without removing cabinet panels. Restore power once. Expected result: if airflow was the cause, the code clears; if it returns, stop there.
When to call a pro
Call a licensed HVAC technician if L9 returns after airflow is corrected or the unit trips quickly after startup. Tell them the code is high-power protection.
View the fix ->

P8

P8 means the outdoor inverter module temperature is too high. Poor outdoor airflow can contribute, but the module itself is inside the outdoor electrical section and is not homeowner-serviceable. Manual trigger: P8 means the inverter module is overheating.

AdvisoryDIY
Sourced Jul 2026
Applies to
Livo R32
Homeowner fix
Clear leaves, snow, and loose debris from around the outdoor unit without removing panels, then reset power once. Expected result: an outdoor-airflow problem clears; if P8 returns, stop there.
When to call a pro
Call a licensed HVAC technician if P8 returns or the outdoor fan is not running normally. Tell them the code is module overheating protection.
View the fix ->