Senville error codes

Senville displays an alphanumeric code on the indoor unit, and the 44 codes below cover the AURA, ELITE and LETO lines. Senville builds on a Midea control platform, so the EC, EH and PC code families here match those on ACiQ and Midea systems - if you have cross-shopped those brands, the diagnostics will look familiar.

Status displays
7
Error codes
44

Unit applicability

Match your unit before reading the table

This table is sourced for LETO Series. If your unit is a different generation or product line not named here, the same display code may vary by generation.

Common codes first

Most broadly applicable documented codes

Ranking basis: we do not have failure-frequency telemetry. These are ordered by breadth of affected systems in the SplitAtlas catalog - the documented product line's published model count, whether the same code appears on more than one product line, and any manual applicability notes we hold. This is a breadth ranking, not a popularity claim.

EC07

EC07 means the outdoor unit is not seeing outdoor fan speed in the range it expects. The fan may be blocked, failing, or not being driven correctly.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the unit off and look only through the outdoor grille for obvious leaves, snow, or debris. Remove loose debris outside the cabinet, restore power once, and stop if EC07 returns.
View the fix
EC51

EC51 means the outdoor control board is not getting valid feedback from its EEPROM memory. This is not a remote setting or homeowner-adjustable parameter.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
View the fix
EC52

EC52 means the outdoor coil temperature reading is outside the valid electrical range. The system cannot safely judge outdoor coil temperature.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
View the fix
EC53

EC53 means the outdoor ambient-air temperature reading is not believable to the board. The system may stop because it cannot apply outdoor operating limits correctly.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
View the fix
EC54

EC54 means the discharge temperature sensor signal is out of range. The system cannot verify compressor discharge temperature, so it should not be forced to keep running.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
View the fix
EC56

EC56 means the system cannot trust the indoor coil outlet temperature sensor located at the outdoor low-pressure valve circuit.

AdvisoryTechnician
Breadth evidence
8 published catalog models on its documented product line.
Safe first check
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
View the fix

Safe first checks

Checks you can do without opening the unit

These codes have homeowner-safe steps such as filters, airflow, condensate/drain checks, remote/controller items, or a single safe power reset. If the code returns, stop at the boundary in the card.

EC07Technician

Turn the unit off and look only through the outdoor grille for obvious leaves, snow, or debris. Remove loose debris outside the cabinet, restore power once, and stop if EC07 returns.

Read the full code guide
EC51Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

Read the full code guide
EC52Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

Read the full code guide
EC53Technician

Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.

Read the full code guide

Senville mini-splits

Use the Senville catalog to connect these manual error codes to current model pages and replacement options.

Status displays

DF

DF is a normal defrost display. The Senville LETO guide says no action is needed during this normal operation.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Let defrost finish. The unit should return to normal heating after the cycle.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

CL

CL is a Senville LETO filter cleaning reminder. It is shown briefly at power-on to prompt filter maintenance.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Clean the indoor filters and reinstall them fully before restarting the unit.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

FP

FP is a normal low-temperature heating display used around 8 degrees C. It does not mean a component has failed.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Leave the unit in the selected mode unless you did not intend to use low-temperature heating.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

FC

FC is a forced-cooling display. The Senville guide treats it as an operating mode to check if it was accidentally enabled.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Cancel forced cooling from the control sequence or remote if it was not intentional.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

AP

AP means the unit is in Wi-Fi pairing mode. It is not an HVAC fault by itself.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Finish Wi-Fi setup or exit pairing mode if you did not intend to connect the unit.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

CP

CP means the unit was turned off by remote command. It is a status display, not a failed part.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Restart the unit with the remote if you want it running.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

F

F is a filter replacement reminder on some Senville LETO models. It is a maintenance display, not a refrigeration or electrical fault.

Not an error
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Inspect the filters and replace or clean them according to the model instructions.
Status note
This is a normal status display or maintenance reminder, not a fault code.
View the fix ->

All error codes

EC07

EC07 means the outdoor unit is not seeing outdoor fan speed in the range it expects. The fan may be blocked, failing, or not being driven correctly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off and look only through the outdoor grille for obvious leaves, snow, or debris. Remove loose debris outside the cabinet, restore power once, and stop if EC07 returns.
When to call a pro
Call a licensed HVAC technician if the outdoor fan is not visibly blocked, the fan blade is damaged, or EC07 returns. Tell them the code is outdoor fan speed out of control.
View the fix ->

EC51

EC51 means the outdoor control board is not getting valid feedback from its EEPROM memory. This is not a remote setting or homeowner-adjustable parameter.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EC51 returns after one reset or appears after a board/service visit. Tell them the manual points to the outdoor EEPROM circuit.
View the fix ->

EC52

EC52 means the outdoor coil temperature reading is outside the valid electrical range. The system cannot safely judge outdoor coil temperature.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EC52 returns after one reset. Tell them the code points to the outdoor coil T3 sensor circuit.
View the fix ->

EC53

EC53 means the outdoor ambient-air temperature reading is not believable to the board. The system may stop because it cannot apply outdoor operating limits correctly.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EC53 returns after one reset. Tell them the code points to outdoor ambient sensor T4.
View the fix ->

EC54

EC54 means the discharge temperature sensor signal is out of range. The system cannot verify compressor discharge temperature, so it should not be forced to keep running.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EC54 returns after one reset. Tell them the code points to compressor discharge sensor T5.
View the fix ->

EC56

EC56 means the system cannot trust the indoor coil outlet temperature sensor located at the outdoor low-pressure valve circuit.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EC56 returns after one reset. Tell them the code points to the evaporator coil outlet T2B sensor circuit.
View the fix ->

EH0

EH0 means the indoor main board and display board are not exchanging the expected signal. Senville points to wiring between the boards or either board as the repair area.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. Do not remove the front cover or move internal wiring.
When to call a pro
Call a licensed HVAC technician if EH0 returns after one safe reset or basic airflow checks.
View the fix ->

EH00

EH00 means the indoor control board is not getting valid feedback from its EEPROM memory. This usually appears after installation, service, or a board fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EH00 returns after one reset. Tell them the manual points to the indoor EEPROM circuit.
View the fix ->

EH02

EH02 points to an indoor control-board electrical timing signal fault. The Senville guide identifies indoor PCB replacement as the repair path.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe and then leave the unit off if the code returns. Do not open electrical covers.
When to call a pro
Call a licensed HVAC technician if EH02 returns after one safe reset or basic airflow checks.
View the fix ->

EH03

EH03 means the indoor blower is not reporting a normal speed. A clogged washable filter or blocked outlet can contribute, but repeated EH03 usually needs motor/board diagnosis.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off, clean the washable indoor filter, and check only for obvious blockage at the return or outlet. If the filter frame is missing or damaged, replace only the user-removable air filter after verifying your indoor model. Restart once; if EH03 returns, stop there.
When to call a pro
Call a licensed HVAC technician if EH03 returns after the filter and visible airflow path are clear, or if the blower does not run normally. Tell them the code is indoor fan speed malfunction.
View the fix ->

EH0A

EH0A is another homeowner-facing indoor EEPROM parameter display. It points to the indoor board memory/configuration path, not a remote setting.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EH0A returns after one reset or appears after a board replacement. Tell them the manual points to indoor EEPROM feedback.
View the fix ->

EH60

EH60 means the indoor unit cannot trust the room-temperature sensor. Comfort can swing or the unit may stop because it does not know the room temperature accurately.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EH60 returns after one reset. Tell them the code points to indoor room sensor T1.
View the fix ->

EH61

EH61 means the indoor evaporator coil temperature sensor is out of range. The system cannot protect the indoor coil accurately.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EH61 returns after one reset. Tell them the code points to indoor coil sensor T2.
View the fix ->

EHC1

EHC1 is a refrigerant leak detection alarm. Senville directs technicians to leak-test the system and recharge after repair.

Stop useTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off if safe, ventilate the room, and avoid using the unit until it is inspected. Do not open panels or attempt refrigerant work.
When to call a pro
Call a licensed HVAC technician promptly if EHC1 appears.
View the fix ->

EHC2

EHC2 combines a refrigerant leak alarm with a refrigerant sensor operating out of range. Senville identifies both sensor replacement and refrigerant-line repair as possible work.

Stop useTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off if safe and ventilate. Do not bypass the alarm, open the unit, or restart repeatedly.
When to call a pro
Call a licensed HVAC technician promptly if EHC2 appears.
View the fix ->

EHC3

EHC3 means the refrigerant sensor is not operating within its expected range. Senville identifies sensor replacement as the repair path.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If EHC3 remains, leave the unit off and do not open the indoor unit.
When to call a pro
Call a licensed HVAC technician if EHC3 appears or returns.
View the fix ->

EL01

EL01 means at least one indoor unit and the outdoor unit are not exchanging control signals reliably. The two sides of the system cannot coordinate normal operation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if EL01 returns after one reset, appears on a new installation, or affects multiple zones. Tell them the code is indoor/outdoor communication.
View the fix ->

EL0C

EL0C means the unit detects insufficient refrigerant. Senville's detailed article lists installation issues, improper valve positions, excessive pipe length, and refrigerant leakage as common causes.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off if it is not cooling/heating or if ice is present. Check filters and airflow only. Do not open valves, add refrigerant, or tighten refrigerant fittings.
When to call a pro
Call a licensed HVAC technician before using the system normally again. Tell them the display is EL0C and the table says system lacks refrigerant.
View the fix ->

FHCC

FHCC means the refrigerant sensor module is not operating normally. Senville identifies replacement of the sensor module as the repair path.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If FHCC remains, leave the unit off and do not open the indoor unit.
When to call a pro
Call a licensed HVAC technician if FHCC appears or returns after a reset.
View the fix ->

LC06

LC06 means the inverter power module temperature is too high. Senville points to improving cooling and ventilation.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off and clear debris from around the outdoor unit. Do not open the cabinet or touch electrical parts.
When to call a pro
Call a licensed HVAC technician if LC06 returns after one safe reset or basic airflow checks.
View the fix ->

PC00

PC00 means the outdoor inverter power module reported an abnormal compressor-drive condition. It can shut the system down to protect expensive electronics and the compressor.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if PC00 returns after one reset. Tell them the code is outdoor IPM module protection.
View the fix ->

PC01

PC01 means the outdoor unit saw supply voltage or DC bus voltage outside the expected range. It may be a utility/brownout issue, wiring issue, or outdoor-board fault.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off and note whether lights dimmed, storms occurred, or other appliances had power trouble. Reset once only after power is stable. If PC01 returns or any breaker trips, stop there.
When to call a pro
Call a licensed HVAC technician or electrician if PC01 returns, a breaker trips, or other circuits show voltage trouble. Tell them the code is outdoor voltage protection.
View the fix ->

PC02

PC02 means the system protected the compressor top or inverter module from high temperature. Dirty airflow can contribute, but repeated PC02 can point to sealed-system, compressor, or board problems.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off, clean indoor filters, and clear only loose debris around the outdoor unit without removing panels. Restore power once after the unit has cooled; if PC02 returns, stop using it.
When to call a pro
Call a licensed HVAC technician if PC02 returns after airflow is corrected. Tell them the code is compressor top/IPM temperature protection.
View the fix ->

PC03

PC03 means the refrigerant pressure protection circuit opened on either low or high pressure. This is sealed-system diagnosis, not a code to keep clearing.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off, make sure filters and outdoor airflow are not obviously blocked, and reset once only. Do not attach gauges or add refrigerant.
When to call a pro
Call a licensed HVAC technician if PC03 returns. Tell them the display is pressure protection and note whether it happened in heating or cooling.
View the fix ->

PC04

PC04 means the outdoor inverter drive could not operate the compressor normally. This can involve the compressor, IPM, outdoor board, or drive wiring.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off with the remote, then power cycle once at the breaker or disconnect if you can do that safely. Expected result: a temporary control fault clears; if the code returns, stop resetting and schedule service.
When to call a pro
Call a licensed HVAC technician if PC04 returns after one reset or the outdoor unit will not start. Tell them the code is inverter compressor drive error.
View the fix ->

PC06

PC06 means the compressor discharge temperature has exceeded the protected range. Senville points to coil cleanliness, refrigerant condition, and airflow.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off, clean the filter, and clear outdoor debris. Do not keep running the unit if it restarts and trips again.
When to call a pro
Call a licensed HVAC technician if PC06 returns after one safe reset or basic airflow checks.
View the fix ->

PC08

PC08 means current draw is outside the safe range. Senville points to current draw, fan resistance, and wiring checks.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Clean filters and clear outdoor airflow. Do not open electrical panels or reset a tripping breaker repeatedly.
When to call a pro
Call a licensed HVAC technician if PC08 returns after one safe reset or basic airflow checks.
View the fix ->

PC0A

PC0A means the outdoor condenser temperature is too high. Senville points first to condenser cleaning and outdoor airflow.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off and remove leaves, lint, or debris around the outdoor unit. Keep clearance around the cabinet and restart once after it cools.
When to call a pro
Call a licensed HVAC technician if PC0A returns after one safe reset or basic airflow checks.
View the fix ->

PC0F

PC0F means the power factor correction circuit has protected or faulted. This is an outdoor electrical power-board diagnostic.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If PC0F returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC0F returns after one safe reset or basic airflow checks.
View the fix ->

PC0L

PC0L means the system is protecting itself because outdoor conditions are below the allowed operating range for that mode. This is usually an operating-limit condition, not a failed part.

AdvisoryDIY
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Leave power applied to the outdoor unit and wait for outdoor conditions to return inside the unit's operating range. Expected result: the code clears when conditions allow normal operation.
When to call a pro
Call a licensed HVAC technician if PC0L appears in mild weather, will not clear after conditions improve, or the system is being asked to cool/heat in conditions it should support.
View the fix ->

PC10

PC10 is in Senville's PC 10-12 group for AC voltage and DC bus issues. These are outdoor power-electronics protections.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off and note any wider power problems in the home. Do not open electrical covers or test capacitors.
When to call a pro
Call a licensed HVAC technician if PC10 returns after one safe reset or basic airflow checks.
View the fix ->

PC11

PC11 is in Senville's PC 10-12 group for AC voltage and DC bus issues. These are outdoor power-electronics protections.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off and note any wider power problems in the home. Do not open electrical covers or test capacitors.
When to call a pro
Call a licensed HVAC technician if PC11 returns after one safe reset or basic airflow checks.
View the fix ->

PC12

PC12 is in Senville's PC 10-12 group for AC voltage and DC bus issues. These are outdoor power-electronics protections.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the system off and note any wider power problems in the home. Do not open electrical covers or test capacitors.
When to call a pro
Call a licensed HVAC technician if PC12 returns after one safe reset or basic airflow checks.
View the fix ->

PC30

PC30 is in Senville's PC 30-31 group for system pressure protection. It points to refrigerant charge and blockage checks.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Clean filters and clear outdoor airflow. Do not connect gauges, add refrigerant, or open service valves.
When to call a pro
Call a licensed HVAC technician if PC30 returns after one safe reset or basic airflow checks.
View the fix ->

PC31

PC31 is in Senville's PC 30-31 group for system pressure protection. It points to refrigerant charge and blockage checks.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Clean filters and clear outdoor airflow. Do not connect gauges, add refrigerant, or open service valves.
When to call a pro
Call a licensed HVAC technician if PC31 returns after one safe reset or basic airflow checks.
View the fix ->

PC40

PC40 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC40 returns after one safe reset or basic airflow checks.
View the fix ->

PC41

PC41 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC41 returns after one safe reset or basic airflow checks.
View the fix ->

PC42

PC42 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC42 returns after one safe reset or basic airflow checks.
View the fix ->

PC43

PC43 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC43 returns after one safe reset or basic airflow checks.
View the fix ->

PC44

PC44 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC44 returns after one safe reset or basic airflow checks.
View the fix ->

PC45

PC45 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC45 returns after one safe reset or basic airflow checks.
View the fix ->

PC46

PC46 is in Senville's PC 40-46 group for compressor control or signal issues. The guide points technicians to the compressor, sensors, and control boards.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Power cycle once if safe. If the code returns, leave the system off and do not open the outdoor unit.
When to call a pro
Call a licensed HVAC technician if PC46 returns after one safe reset or basic airflow checks.
View the fix ->

PH90

PH90 is in Senville's PH 90/91 evaporator temperature protection group. The first safe checks are airflow and filters.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off if ice is present, let it thaw, clean filters, and clear furniture or curtains from the air path.
When to call a pro
Call a licensed HVAC technician if PH90 returns after one safe reset or basic airflow checks.
View the fix ->

PH91

PH91 is in Senville's PH 90/91 evaporator temperature protection group. The first safe checks are airflow and filters.

AdvisoryTechnician
Sourced Jul 2026
Applies to
LETO Series
Homeowner fix
Turn the unit off if ice is present, let it thaw, clean filters, and clear furniture or curtains from the air path.
When to call a pro
Call a licensed HVAC technician if PH91 returns after one safe reset or basic airflow checks.
View the fix ->