SplitAtlas

Panasonic / Project Series High Wall

Panasonic Project High Wall 9k R-454B 208/230V Mini-Split

Certified capacity
9,000 BTU/h[2]
SEER2
24.6 SEER2[2]
Heating floor
-13 F[1]
Voltage
230 V[1]
Install path
Professional install

Panasonic's Project Series High Wall 9k is a seasonal-heating standout: its HSPF2 of 13 is among the highest in our entire catalog, paired with SEER2 24.6 / EER2 14.7 on next-gen R-454B and rated heating operation to -13F. Panasonic is a major, reliability-focused Japanese brand, and this contractor-oriented line delivers premium efficiency without the top-brand price of Mitsubishi or Fujitsu.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Need this installed?

Get installation quotes
Panasonic Project Series High Wall 9,000 BTU R-454B 208/230V (CS-YM9CKUW / CU-YM9CBUC)

Image: Panasonic

Data completeness: 92%
Last sourced
Jul 23, 2026

SplitAtlas score

9.0 / 10

Methodology
Cooling efficiencyAbove average

(24.6 SEER2) among <=9k systems

Heating efficiencyTop quartile

(13.0 HSPF2) among <=9k systems

Cold-weather performanceAbove average

(82% heat retained at 5F; -13 F heating floor) among <=9k systems

NoiseTop 10%

(-45.5 dBA indoor min / 52.5 dBA outdoor) among <=9k systems

Feature setTop 10%

(7 verified features) across the catalogue

Documentation & partsBelow average

(10 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

9,000BTU/h[2]

Rated heating

10,000BTU/h[2]

Best-fit use cases

A bedroom or office in a cold-capable climate where heating efficiency is the priority and the buyer wants premium seasonal performance without paying Mitsubishi/Fujitsu money.

Buyer review snapshot

Best for / skip if

Best for

  • High-efficiency shortlists; SEER2 is 24.6.

Install difficulty

Professional install
  • Electrical: 230V; MCA 12 A; breaker/fuse 15 A.
  • Line set: connection type not sourced; precharged 25 ft; max 82 ft.

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-23.

Source date

Model data sourced
Jul 23, 2026
Page reviewed
Jul 23, 2026
Source-backed records
3
Newest source retrieved
Jul 23, 2026

Review methodology

Strengths

  • Exceptional HSPF2 13 - among the best seasonal heating efficiency in the database.
  • SEER2 24.6 with -13F rated heating on low-GWP R-454B.
  • Major-brand reliability at a step below the premium-brand price.

Weaknesses

  • Professional installation required; no confirmed online retail price.
  • A single-room unit - larger spaces need the 12k or up.

Climate suitability

Minimum heating ambient
-13 F[1]
Rated heating at 5F
8,200 BTU/h[2]
Rated heating at 17F
9,300 BTU/h[2]
Rated heating at 47F
10,000 BTU/h[2]

Specifications

Show
Manufacturer
Panasonic
Brand
Panasonic
Product line
Project Series High Wall
Model number
CS-YM9CKUW indoor / CU-YM9CBUC outdoor
Indoor unit model
CS-YM9CKUW
Outdoor unit model
CU-YM9CBUC
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/h[2]
Rated heating capacity
10,000 BTU/h[2]
Voltage
230 V[1]
MCA
12 A[1]
Maximum fuse or breaker size
15 A[1]
Breaker needed
not published
SEER2
24.6 SEER2[2]
EER2
14.7 EER2[2]
HSPF2 (Region 4)
13 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
3.66 COP[1]
COP at 5F
2.33 COP[2]
Minimum outdoor heating temperature
-13 F[1]
Minimum outdoor cooling temperature
-13 F[1]
Maximum outdoor temperature
122 F[1]
Indoor noise range
19.5-45.5 dB(A)[1]
Outdoor noise rating
52.5 dBA[1]
Indoor weight
19 lb[1]
Outdoor weight
62 lb[1]
Refrigerant
R-454B[1]
Refrigerant charge
32.45 oz[1]
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Panasonic Project Series High Wall professional-install sources publish refrigerant piping size, maximum length, and height difference, but no included line set.
Maximum line-set length
82 ft[1]
Max line set per indoor
not published
Maximum elevation difference
49 ft[1]
Max height between indoor units
not published
Wi-Fi support
not supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
218027960[2]
Warranty
not published
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-23.
Available retailers
not published
Manual links
AHRI certificate 218027960, AHRI public directory record 218027960, ENERGY STAR record 4520553 for CU-YM9CBUC / CS-YM9CKUW, HVACDirect exact Panasonic Project Series High Wall model search summary, Panasonic Project Series High Wall 9,000 BTU submittal extracted text, Panasonic Project Series catalog extracted text, Panasonic Project Series High Wall manufacturer page snapshot, Panasonic Project Series High Wall source manifest, Panasonic Project Series Heat Pump Solutions catalog, Panasonic Project Series High Wall 9,000 BTU submittal
Specification sheet
Panasonic Project Series Heat Pump Solutions catalog
Last sourced date
Jul 23, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
12 A[1]
Breaker needed
not published
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
14/4 AWG connection wiring[1]

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
25 ft[1]
Included line-set length
Panasonic Project Series High Wall professional-install sources publish refrigerant piping size, maximum length, and height difference, but no included line set.
Maximum line-set length
82 ft[1]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
31-1/2 x 7-7/8 x 11-5/8 in[1]
Outdoor dimensions
30-1/8 x 11-7/8 x 21-7/8 in[1]
Indoor weight
19 lb[1]
Outdoor weight
62 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Panasonic Project Series High Wall 9,000 BTU R-454B 208/230V (CS-YM9CKUW / CU-YM9CBUC) myself, or do I need a pro?
Panasonic Project Series High Wall 9,000 BTU R-454B 208/230V (CS-YM9CKUW / CU-YM9CBUC) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Panasonic Project Series High Wall 9,000 BTU R-454B 208/230V (CS-YM9CKUW / CU-YM9CBUC) keep heating in a cold winter?
The manufacturer publishes 8,200 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 13 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Panasonic Project Series High Wall 9,000 BTU R-454B 208/230V (CS-YM9CKUW / CU-YM9CBUC) need?
Published electrical requirements: 230 V voltage, 12 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 82 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.

Data sources

Show
  1. Panasonic Corporation of North America: CS-YM9CKUW & CU-YM9CBUC Panasonic Project Series High Wall submittalSourced - manufacturer technical document

    Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Manufacturer wire notes and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI public detail 218027960 for CS-YM9CKUW / CU-YM9CBUCSourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more

  3. ENERGY STAR: ENERGY STAR record 4520553 for CU-YM9CBUC / CS-YM9CKUWSourced - Energy Star listing

    Covers Energy Star status

Last updated

Jul 23, 2026