SplitAtlas

Trane / ML Series R-410A

Trane ML 9k R-410A 115V Mini-Split

Certified capacity
9,000 BTU/h[2]
SEER2
20 SEER2[2]
Heating floor
-4 F[1]
Voltage
115 V[1]
Install path
Professional install

Trane is one of the most respected names in HVAC, and the ML Series 9k carries that badge on a convenient 115V circuit - but buy it with eyes open. This is an R-410A system, and R-410A is the refrigerant being phased out industry-wide; AHRI already lists the ML Series as "Production Stopped" (still certified and sellable, but no longer manufactured).

It is ENERGY STAR certified at SEER2 20, rated to -4F. Think of it as a legacy/closeout unit, not a forward-looking purchase.

1 zoneProfessional installCurrent

Need this installed?

Get installation quotes
Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA)

Image: Trane

Data completeness: 95%
Last sourced
Jul 23, 2026

SplitAtlas score

7.9 / 10

Methodology
Cooling efficiencyBottom quartile

(20.0 SEER2) among <=9k systems

Heating efficiencyAbove average

(10.0 HSPF2) among <=9k systems

Cold-weather performanceBottom quartile

(61.5% heat retained at 17F; -4 F heating floor) among <=9k systems

NoiseTop 10%

(-43 dBA indoor min / 50 dBA outdoor) among <=9k systems

Feature setBelow average

(4 verified features) across the catalogue

Documentation & partsTop quartile

(16 manuals; spec sheet; 10 error-code rows) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

9,000BTU/h[2]

Rated heating

10,900BTU/h[2]

Best-fit use cases

A buyer who specifically wants the Trane name on 115V and is getting it at a genuine closeout price, understanding it is a legacy R-410A system near the end of its production life.

Buyer review snapshot

Install difficulty

Professional install
  • Electrical: 115V; MCA 12 A; breaker/fuse 15 A.
  • Line set: connection type not sourced; max 65 ft.

Alternatives

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-23.

Source date

Model data sourced
Jul 23, 2026
Page reviewed
Jul 23, 2026
Source-backed records
4
Newest source retrieved
Jul 23, 2026

Review methodology

Strengths

  • The Trane name and dealer network, on a standard 115V circuit.
  • ENERGY STAR certified at SEER2 20 with HSPF2 10 - solid mainstream efficiency.

Weaknesses

  • R-410A refrigerant on a "Production Stopped" line - the industry has moved to R-454B/R-32, and R-410A service refrigerant will get scarcer and pricier over the unit's life.
  • Rated only to -4F; professional installation required.
  • A closeout-era product - newer R-454B units from Bosch/Carrier/Midea offer better long-term footing.

Climate suitability

Minimum heating ambient
-4 F[1]
Rated heating at 5F
not published
Rated heating at 17F
6,700 BTU/h[2]
Rated heating at 47F
10,900 BTU/h[2]

Specifications

Show
Manufacturer
Trane
Brand
Trane
Product line
ML Series R-410A
Model number
NTXWMT09A111AA indoor / NTXSMT09A111AA outdoor
Indoor unit model
NTXWMT09A111AA
Outdoor unit model
NTXSMT09A111AA
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/h[2]
Rated heating capacity
10,900 BTU/h[2]
Voltage
115 V[1]
MCA
12 A[1]
Maximum fuse or breaker size
15 A[1]
Breaker needed
not published
SEER2
20 SEER2[2]
EER2
12 EER2[2]
HSPF2 (Region 4)
10 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
3.55 COP[1]
COP at 5F
not published
Minimum outdoor heating temperature
-4 F[1]
Minimum outdoor cooling temperature
14 F[1]
Maximum outdoor temperature
115 F[1]
Indoor noise range
22-43 dB(A)[1]
Outdoor noise rating
50 dBA[1]
Indoor weight
22 lb[1]
Outdoor weight
73 lb[1]
Refrigerant
R-410A[1]
Refrigerant charge
28 oz[1]
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Trane/METUS professional-install submittals publish refrigerant line sizes, precharged length, and maximum piping limits, but no included line set.
Maximum line-set length
65 ft[1]
Max line set per indoor
not published
Maximum elevation difference
40 ft[1]
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
202397887[2]
Warranty
not published
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-23.
Available retailers
not published
Manual links
AHRI certificate 202397887, AHRI public detail 202397887, ENERGY STAR exact row 4467511, Trane NTXWMT09-12A111A installation manual, Trane 18 SEER Wall Mount ML manufacturer page, Trane Single-Zone Heat Pump ML manufacturer page, Trane warranty and registration page, HVACDirect Trane ML search outcomes, Trane NTXSMT09-12A111AA outdoor service manual, Trane NTXWMT-A111A/B indoor service manual, Trane ML source manifest, Trane ML 9,000 BTU extracted submittal text fixture source, Trane ML 9,000 BTU submittal NTXWMT09A111AA / NTXSMT09A111AA, Trane NTXSMT09-12A111AA technical databook, Trane NTXWMT09-12A111AA technical databook, Trane NTXWMT09-12A111A operation manual
Specification sheet
Trane ML 9,000 BTU extracted submittal text fixture source
Last sourced date
Jul 23, 2026

Electrical requirements

Show
Voltage
115 V[1]
Voltage range
115V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
12 A[1]
Breaker needed
not published
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
14 AWG indoor-outdoor[1]

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
not published
Included line-set length
Trane/METUS professional-install submittals publish refrigerant line sizes, precharged length, and maximum piping limits, but no included line set.
Maximum line-set length
65 ft[1]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
31-7/16 x 9-1/8 x 11-5/8 in[1]
Outdoor dimensions
31-1/2 x 11-1/4 x 21-5/8 in[1]
Indoor weight
22 lb[1]
Outdoor weight
73 lb[1]
Drain size
5/8 in[1]

Frequently asked questions

Can I install the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) myself, or do I need a pro?
Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) keep heating in a cold winter?
Rated heating operation extends down to -4 F. Certified heating efficiency is 10 HSPF2. Match that published heating floor against your climate's design temperature - below the low-ambient rating, output can fall off or the system can pause to protect itself.
What electrical circuit does the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) need?
Published electrical requirements: 115 V voltage, 12 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 65 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.

Data sources

Show
  1. Mitsubishi Electric Trane HVAC US LLC: NTXWMT09A111AA & NTXSMT09A111AA Trane ML Series submittalSourced - manufacturer technical document

    Covers Frequency, electrical_spec.guaranteed_voltage_range, electrical_spec.indoor_mca_amps, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI public detail 202397887 for NTXWMT09A111AA / NTXSMT09A111AASourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, EER2, Rated heating capacity, HSPF2 (Region 4), Rated heating at 17F and more

  3. U.S. Environmental Protection Agency ENERGY STAR: ENERGY STAR exact row 4467511 for NTXWMT09A111AA / NTXSMT09A111AASourced - Energy Star listing

    Covers Energy Star status

  4. Trane Residential: Single-Zone Heat Pump ML manufacturer pageSourced - manufacturer product page

    Covers system.lifecycle_status

Last updated

Jul 23, 2026