SplitAtlas

Trane / ML Series R-410A

Trane ML 9k R-410A 115V Mini-Split

Certified capacity
9,000 BTU/h[2]
SEER2
20 SEER2[2]
Heating floor
-4 F[1]
Voltage
115 V[1]
Install path
Professional install

The Trane ML Series 9k carries the Trane name on a convenient 115V circuit - but buy it with eyes open. This is an R-410A system, and R-410A is the refrigerant being phased out industry-wide; AHRI already lists the ML Series as "Production Stopped" (still certified and sellable, but no longer manufactured).

It is ENERGY STAR certified at SEER2 20, rated to -4F. Think of it as a legacy/closeout unit, not a forward-looking purchase.

1 zoneProfessional installCurrent

Need this installed?

Get installation quotes
Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA)

Image: Trane

Data completeness: 95%
Last sourced
Jul 23, 2026

SplitAtlas score

7.8 / 10

Methodology
Cooling efficiencyBottom quartile

(20.0 SEER2) among <=9k systems

Heating efficiencyAbove average

(10.0 HSPF2) among <=9k systems

Cold-weather performanceBottom quartile

(17F certified capacity: 61.5% of the 47F rating; -4 F heating floor) among <=9k systems

NoiseAbove average

(22 dBA indoor min / 50 dBA outdoor) among <=9k systems

Feature setBelow average

(4 verified features) across the catalogue

Documentation & partsTop quartile

(16 manuals; spec sheet; 10 error-code rows) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

9,000BTU/h[2]

Rated heating

10,900BTU/h[2]

Best-fit use cases

A buyer who specifically wants the Trane name on 115V and is getting it at a genuine closeout price, understanding it is a legacy R-410A system near the end of its production life.

Buyer review snapshot

Install difficulty

Professional install
  • Electrical: 115V; MCA 12 A; breaker/fuse 15 A.
  • Line set: connection type not sourced; max 65 ft.

Alternatives

Availability and price context

This system needs a professional install, so its real price is an installed quote that depends on your home. We don't link to a listing for this exact model; get installation quotes to price it.

Source date

Model data sourced
Jul 23, 2026
Page reviewed
Jul 23, 2026
Source-backed records
4
Newest source retrieved
Jul 23, 2026

Review methodology

Strengths

  • The Trane name and dealer network, on a standard 115V circuit.
  • ENERGY STAR certified at SEER2 20 with HSPF2 10 - solid mainstream efficiency.

Weaknesses

  • R-410A refrigerant on a "Production Stopped" line - the industry has moved to R-454B/R-32, and R-410A service refrigerant will get scarcer and pricier over the unit's life.
  • Rated only to -4F; professional installation required.
  • A closeout-era product - newer R-454B units from Bosch/Carrier/Midea offer better long-term footing.

Climate suitability

Minimum heating ambient
-4 F[1]
Certified heating at 5F
not published
Maximum heating at 5F (manufacturer)
5,990 BTU/h[1]
Rated heating at 17F
6,700 BTU/h[2]
Rated heating at 47F
10,900 BTU/h[2]

Specifications

Show
Manufacturer
Trane
Brand
Trane
Product line
ML Series R-410A
Model number
NTXWMT09A111AA indoor / NTXSMT09A111AA outdoor
Indoor unit model
NTXWMT09A111AA
Outdoor unit model
NTXSMT09A111AA
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/h[2]
Rated heating capacity
10,900 BTU/h[2]
Voltage
115 V[1]
MCA
12 A[1]
Maximum fuse or breaker size
15 A[1]
Breaker needed
not published
SEER2
20 SEER2[2]
EER2
12 EER2[2]
HSPF2 (Region 4)
10 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
3.55 COP[1]
COP at 5F
not published
Minimum outdoor heating temperature
-4 F[1]
Minimum outdoor cooling temperature
14 F[1]
Maximum outdoor temperature
115 F[1]
Indoor noise range
22-43 dB(A)[1]
Outdoor noise rating
50 dBA[1]
Indoor weight
22 lb[1]
Outdoor weight
73 lb[1]
Refrigerant
R-410A[1]
Refrigerant charge
28 oz[1]
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Trane/METUS professional-install submittals publish refrigerant line sizes, precharged length, and maximum piping limits, but no included line set.
Maximum line-set length
65 ft[1]
Max line set per indoor
not published
Maximum elevation difference
40 ft[1]
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
202397887[2]
Warranty
not published
Install path
Professional install
Retail price
Installed quote only
Available retailers
not published
Manual links
AHRI certificate 202397887, AHRI public detail 202397887, ENERGY STAR exact row 4467511, Trane NTXWMT09-12A111A installation manual, Trane 18 SEER Wall Mount ML manufacturer page, Trane Single-Zone Heat Pump ML manufacturer page, Trane warranty and registration page, Trane NTXSMT09-12A111AA outdoor service manual, Trane NTXWMT-A111A/B indoor service manual, Trane ML 9,000 BTU extracted submittal text fixture source, Trane ML 9,000 BTU submittal NTXWMT09A111AA / NTXSMT09A111AA, Trane NTXSMT09-12A111AA technical databook, Trane NTXWMT09-12A111AA technical databook, Trane NTXWMT09-12A111A operation manual
Specification sheet
Trane ML 9,000 BTU extracted submittal text fixture source
Last sourced date
Jul 23, 2026

Electrical requirements

Show
Voltage
115 V[1]
Voltage range
115V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
12 A[1]
Breaker needed
not published
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
14 AWG indoor-outdoor[1]

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
not published
Included line-set length
Trane/METUS professional-install submittals publish refrigerant line sizes, precharged length, and maximum piping limits, but no included line set.
Maximum line-set length
65 ft[1]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
31-7/16 x 9-1/8 x 11-5/8 in[1]
Outdoor dimensions
31-1/2 x 11-1/4 x 21-5/8 in[1]
Indoor weight
22 lb[1]
Outdoor weight
73 lb[1]
Drain size
5/8 in[1]

Frequently asked questions

Can I install the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) myself, or do I need a pro?
Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) keep heating in a cold winter?
Rated heating operation extends down to -4 F. Certified heating efficiency is 10 HSPF2. Match that published heating floor against your climate's design temperature - below the low-ambient rating, output can fall off or the system can pause to protect itself.
What electrical circuit does the Trane ML Series 9,000 BTU R-410A 115V (NTXWMT09A111AA / NTXSMT09A111AA) need?
Published electrical requirements: 115 V voltage, 12 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 65 ft. Measure the planned routing before ordering.

Data sources

Show
  1. Mitsubishi Electric Trane HVAC US LLC: NTXWMT09A111AA & NTXSMT09A111AA Trane ML Series submittalSourced - manufacturer technical document

    Covers Frequency, electrical_spec.guaranteed_voltage_range, electrical_spec.indoor_mca_amps, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI public detail 202397887 for NTXWMT09A111AA / NTXSMT09A111AASourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, EER2, Rated heating capacity, HSPF2 (Region 4), Rated heating at 17F and more

  3. U.S. Environmental Protection Agency ENERGY STAR: ENERGY STAR exact row 4467511 for NTXWMT09A111AA / NTXSMT09A111AASourced - Energy Star listing

    Covers Energy Star status

  4. Trane Residential: Single-Zone Heat Pump ML manufacturer pageSourced - manufacturer product page

    Covers system.lifecycle_status

Last updated

Jul 23, 2026