SplitAtlas

Cooper & Hunter / Olivia Series

Cooper Hunter Olivia 18k Regular R-454B 208/230V Mini-Split

Certified capacity
18,000 BTU/h[3]
SEER2
24 SEER2[3]
Heating floor
-13 F[1]
Voltage
230 V[1]
Install path
Professional install

An efficient mid-line all-rounder, the standard Olivia 18k pairs a strong 24 SEER2 and 13.5 EER2 with full 18,000 BTU heat on mild days. As it gets cold the heat eases (15,000 BTU at 17F, 13,000 at 5F), so it is built for temperate climates rather than hard winters.

For a medium room where cooling efficiency matters and winters are mild, it is a well-priced, efficient fit. Cold-climate buyers should step up to the Olivia Hyper 18k. Professional install recommended.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Need this installed?

Get installation quotes
Data completeness: 100%
Last sourced
Aug 29, 2026

SplitAtlas score

8.7 / 10

Methodology
Cooling efficiencyTop quartile

(24.0 SEER2) among 18k systems

Heating efficiencyTop quartile

(11.1 HSPF2) among 18k systems

Cold-weather performanceBelow average

(72.2% heat retained at 5F; -13 F heating floor) among 18k systems

NoiseBelow average

(25 dBA indoor min / 56 dBA outdoor) among 18k systems

WarrantyBelow average

(5 yr parts / 7 yr compressor) across the catalogue

Feature setTop quartile

(6 verified features) across the catalogue

Documentation & partsTop quartile

(5 manuals; spec sheet; parts channel) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

18,000BTU/h[3]

Rated heating

18,000BTU/h[3]

Buyer review snapshot

Best for / skip if

Best for

  • High-efficiency shortlists; SEER2 is 24.

Install difficulty

Professional flared-line install
  • Electrical: 230V; MCA 19 A; breaker/fuse 20 A.
  • Line set: Flared line connections; precharged 25 ft; max 98.4 ft.

Alternatives

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-08-29.

Source date

Model data sourced
Aug 29, 2026
Page reviewed
Jul 24, 2026
Source-backed records
6
Newest source retrieved
Aug 29, 2026

Warranty tiers

Warranty: 5 years parts and 7 years compressor as standard.

Review methodology

Model context

Structured ratings
Certification: ENERGY STAR certified. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.

Strengths

  • Efficient cooling for a 1.5-ton head at 24 SEER2 / 13.5 EER2.
  • Full 18,000 BTU of heat at 47F, ENERGY STAR certified.

Weaknesses

  • Heating tapers to 13,000 BTU at 5F in deep cold.
  • Cooper & Hunter's support network is lighter than premium brands; professional install recommended.

Climate suitability

Minimum heating ambient
-13 F[1]
Rated heating at 5F
13,000 BTU/h[3]
Rated heating at 17F
15,000 BTU/h[3]
Rated heating at 47F
18,000 BTU/h[3]

Specifications

Show
Manufacturer
Cooper & Hunter
Brand
Cooper & Hunter
Product line
Olivia Series
Model number
CH-R18MOLVWM-230VI indoor / CH-RES18-230VO outdoor
Indoor unit model
CH-R18MOLVWM-230VI
Outdoor unit model
CH-RES18-230VO
Number of zones
1
Max indoor units
not published
Rated cooling capacity
18,000 BTU/h[3]
Rated heating capacity
18,000 BTU/h[3]
Voltage
230 V[1]
MCA
19 A[1]
Maximum fuse or breaker size
20 A[1]
Breaker needed
not published
SEER2
24 SEER2[3]
EER2
13.5 EER2[3]
HSPF2 (Region 4)
11.1 HSPF2[3]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
2.35 COP[3]
Minimum outdoor heating temperature
-13 F[1]
Minimum outdoor cooling temperature
-13 F[1]
Maximum outdoor temperature
122 F[1]
Indoor noise range
43/35/25 dB(A)[1]
Outdoor noise rating
56 dBA[1]
Indoor weight
27.56 lb[1]
Outdoor weight
99.87 lb[1]
Refrigerant
R-454B[3]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 1/2 in suction
Included line-set length
Cooper&Hunter online kits can be sold with different line-set/accessory bundles; the AHRI-certified indoor/outdoor pair has no single included line-set length.
Maximum line-set length
98.4 ft[1]
Max line set per indoor
not published
Maximum elevation difference
65.6 ft[1]
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[4]
AHRI certification number
215864149[3]
Warranty
Standard: 5 yr parts / 7 yr compressor (standard registration/installation terms). 5-year parts / 7-year compressor limited warranty with registration requirements.
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-08-29.
Available retailers
not published
Manual links
AHRI public directory record 215864149, ENERGY STAR exact check 215864149, Installation Manual R454B Outdoor units, Cooper&Hunter CH-RES18-230VO official product page, Cooper&Hunter CH-RES18-230VO + CH-R18MOLVWM-230VI support-material submittal/spec table
Specification sheet
Cooper&Hunter CH-RES18-230VO + CH-R18MOLVWM-230VI support-material submittal/spec table
Last sourced date
Aug 29, 2026

Parts and filters

Fits Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO). Part numbers and fit notes identify compatibility only; no manufacturer endorsement is implied.

filter-washable

Indoor washable air filter

Fits
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO)
Fit note
Fits CH-R18MOLVWM-230VI / CH-RES18-230VO. Cooper & Hunter documents the indoor air-filter location but does not publish an orderable filter part number in the sourced manual; source by indoor model and serial through Cooper & Hunter or Heat & Cool parts support.
Source
Cooper & Hunter Multi R Installation Manual, Indoor unit overview, page p. 19 (Air purifying filter & Air filter(behind))

remote-control

Wireless remote control

Fits
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO)
Fit note
Fits CH-R18MOLVWM-230VI / CH-RES18-230VO. The sourced Cooper & Hunter manual documents wireless and wired remote-control types but does not publish an orderable remote part number for this indoor SKU; source by indoor model and serial through Cooper & Hunter or Heat & Cool parts support.
Source
Cooper & Hunter Multi R Installation Manual, Optional accessories, page p. 22 (There are two types of remote controls: wired and wireless.)

line-set-installation-kit

Connecting pipe assembly size - 1/4 x 1/2

Fits
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO)
Fit note
Fits CH-R18MOLVWM-230VI / CH-RES18-230VO by the 1/4 x 1/2 liquid/gas dimensions in the Cooper & Hunter accessory table. No offer is attached because the prior Cooper & Hunter retailer pass verified zero exact priced offers, and Heat & Cool monetization is still pending.
Source
Cooper & Hunter Multi R Installation Manual, Installation accessories, page p. 22 (18K Connecting pipe assembly Liquid Side Φ1/4in(Φ6.35) Gas Side Φ1/2in(Φ12.7))
Replacement Parts & Filters

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
19 A[1]
Breaker needed
not published
Maximum breaker size
20 A[1]
Maximum fuse size
20 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
1/2 in[1]
Line connection type
Flared line connections[2]
Precharged length
25 ft[2]
Included line-set length
Cooper&Hunter online kits can be sold with different line-set/accessory bundles; the AHRI-certified indoor/outdoor pair has no single included line-set length.
Maximum line-set length
98.4 ft[1]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
38.07 x 8.46 x 12.56 in[1]
Outdoor dimensions
35.04 x 13.46 x 26.50 in[1]
Indoor weight
27.56 lb[1]
Outdoor weight
99.87 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO) myself, or do I need a pro?
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO) keep heating in a cold winter?
The manufacturer publishes 13,000 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 11.1 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO) need?
Published electrical requirements: 230 V voltage, 19 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 98.4 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 7 yr compressor (standard registration/installation terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. Cooper & Hunter: Cooper&Hunter CH-RES18-230VO + CH-R18MOLVWM-230VI official product page/support materialsSourced - manufacturer product page

    Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. Cooper & Hunter: Flared refrigerant piping installation evidenceSourced - manufacturer technical document

    Covers Line connection type, Precharged length

  3. AHRI certificate #215864149 - search the AHRI DirectorySourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more

  4. ENERGY STAR: ENERGY STAR exact row check for AHRI 215864147Sourced - Energy Star listing

    Covers Energy Star status

  5. Cooper & Hunter: Flared refrigerant piping installation evidenceSourced - manufacturer technical document

    Covers system.diy_status, system.installation_type, system.sales_intent

  6. Cooper & Hunter: Cooper&Hunter warranty and official support pagesSourced - manufacturer product page

    Covers Legacy compressor warranty value, Legacy warranty value, Standard compressor warranty, Standard warranty conditions, Standard parts warranty, Warranty notes

Last updated

Jul 24, 2026