Cooper & Hunter mini splits
Cooper & Hunter is the brand most likely to be mis-shelved as a budget import. We track 111 systems across eleven lines, and every one is a professional install, with flared line sets and a licensed tech for the vacuum and startup. It is not a DIY alternative to MRCOOL. What it offers is breadth: wall units, ceiling cassettes, slim ducted units and multi-zone condensers, all on current-generation R-454B, with no legacy refrigerant anywhere.
The wall-mounted range: - Astoria (13 systems) and Astoria Pro (13 systems) both span 6,000-36,000 BTU at SEER2 19-27.4. - Olivia (15 systems) covers the same capacities at SEER2 19.5-26, with 115V options. - Olivia Midnight (11 systems) is its black-cased version. - MIA (7 systems, SEER2 18.7-21.5) is the budget line.
Around them sit: - Slim Duct concealed units up to 58,000 BTU; - Ceiling Cassette and Ceiling Cassette PRO four-way cassettes up to 48,000 BTU; - a One-Way Cassette; - two multi-zone families: Hyper Multi-Zone at SEER2 24-25.1, and Hyper Heat Multi-Zone, rated to -22F.
Who should buy Cooper & Hunter: a buyer hiring a professional who wants more choice of capacity, form factor and finish than most value brands offer, and a -22F option in most lines. Who should skip it: - anyone planning to install it themselves; - anyone who wants a local dealer network behind the brand; - anyone buying MIA and expecting the rest of the catalog's cold-weather performance.
- Source-backed systems
- 111/5
- Last sourced
- Aug 29, 2026
Products
111
Capacity range
6k BTU to 58k BTU
Price band
not published
Cold-weather options
110
Overview
- Positioning
- Professional install systems
- Country
- United States
- Efficiency range
- SEER2 15.8 to 27.4 / HSPF2 8.5 to 14.8
- Warranty
- Cooper & Hunter multi-zone submittals state a 7-year compressor and 5-year parts standard warranty.
- Dealer/DIY policy
- Cooper & Hunter states installation of its equipment should be performed by a licensed HVAC installer.
What to know about Cooper & Hunter
- The cold rating belongs to the model, not the line. Nine of the eleven lines mix -22F and -13F models. Only Hyper Heat Multi-Zone is rated to -22F throughout, and about half the systems we track carry that rating. For a cold climate, check the exact model page before you buy.
- Astoria and Astoria Pro certify identically. Both lines span 6,000-36,000 BTU at SEER2 19-27.4 with the same mix of -22F and -13F models. The Pro badge doesn't buy you measurable performance, so choose between them on features, finish and price, not on the spec sheet. Anyone paying a meaningful premium for "Pro" on performance grounds is paying for nothing.
- Olivia Midnight is a finish variant, not a performance tier. It is the black-cased Olivia. Its certified efficiency floor is a little higher (SEER2 21.7 vs 19.5), but it stops at 24,000 BTU where standard Olivia reaches 36,000. Buy Midnight because you want the look, and check that the capacity you need is in the range.
- MIA is the outlier, and the one to be careful with. It runs SEER2 18.7-21.5, is rated to -13F at best, and its 12k 115V version heats only to +5F. It's the cheapest way into the brand and the least capable line in it. In a cold climate, spend up to an Astoria or Olivia model rated to -22F.
- The two multi-zone families look alike and are not. Hyper Multi-Zone posts the higher efficiency (SEER2 24-25.1) but is rated only to -13F. Hyper Heat Multi-Zone gives up about a point of SEER2 to hold -22F. For a heating job, take the Hyper Heat.
- 115V is available in Olivia, Olivia Midnight and MIA at the small capacities, which helps if you're avoiding a new 230V circuit. Astoria and Astoria Pro are 230V throughout.
- Cooper & Hunter sells mainly online, so warranty service runs through the brand rather than a local dealer. That is the trade-off behind the price.
Cooper & Hunter sizes and capacities
Room sizes use the same 25 BTU per square foot baseline as our sizing calculator, for a room with average insulation. Run the calculator for a real answer.
- 6,000 BTU: a small bedroom or office, up to roughly 240 sq ft. Available in Astoria, Astoria Pro, Olivia and Olivia Midnight, so C&H covers the small end better than most value brands.
- 9,000 BTU: a bedroom or office up to roughly 350 sq ft. Offered in every wall-mounted line, MIA included, so this is where the choice of line matters most.
- 12,000 BTU: a large bedroom or living room up to roughly 475 sq ft, and the most common 115V capacity.
- 18,000 BTU: an open-plan space or insulated garage up to roughly 700 sq ft, and the entry point for both multi-zone families.
- 24,000 BTU: large open areas up to roughly 950 sq ft. The top of the MIA and Olivia Midnight ranges.
- 36,000 BTU: whole-floor or shop use up to roughly 1,400 sq ft, in Astoria, Astoria Pro and Olivia.
- Above 36,000 BTU: the Slim Duct and ceiling-cassette lines, up to 58,000 and 48,000 BTU, for large open spaces fed from the ceiling.
Cooper & Hunter multi-zone options
Cooper & Hunter runs two multi-zone families covering 18,000 to 36,000 BTU, and the naming actively misleads:
Hyper Multi-Zone (18,000-36,000 BTU) - SEER2 24-25.1, rated to -13F. The efficiency leader.
Hyper Heat Multi-Zone (19,000-36,000 BTU) - SEER2 23-25, rated to -22F. Slightly less efficient, nine degrees more heating capability.
"Hyper" and "Hyper Heat" sound like the same family with a badge; they are different cold-weather products. If you are heating multiple rooms through a real winter, the extra word is the one that matters.
For two rooms, price two single-zone systems first - single-zone avoids the part-load penalty and a failure only takes out one room.
Product table

Astoria Series / Professional install
Cooper & Hunter Astoria 6,000 BTU R-454B 208/230V (CH-RH06MASTWM-230VI / CH-RHP06F9-230VO)
- Capacity
- 6,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.5 / HSPF2 14.8
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 6,000 BTU R-454B 208/230V (CH-PRO06MASTWM-230VI / CH-RHP06F9-230VO)
- Capacity
- 6,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.5 / HSPF2 14.8
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 6,000 BTU R-454B 208/230V (CH-R06MOLVWM-230VI / CH-RHP06F9-230VO)
- Capacity
- 6,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.3 / HSPF2 14.6
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 6,000 BTU R-454B 208/230V (CH-RB06MOLVWM-230VI / CH-RHP06F9-230VO)
- Capacity
- 6,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.3 / HSPF2 14.6
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO)
- Capacity
- 6,500BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22 / HSPF2 12
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 7,000 BTU R-454B 208/230V (CH-RS06-12MDT-MS / CH-RHP06F9-230VO)
- Capacity
- 6,500BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 13.8
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 9,000 BTU R-454B 208/230V (CH-RH09MCT / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.6 / HSPF2 11.3
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 9,000 BTU R-454B 208/230V (CH-RH09MCT / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.6 / HSPF2 12.1
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 9,000 BTU R-454B 208/230V (CH-RH09MASTWM-230VI / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.8 / HSPF2 12.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 9,000 BTU R-454B 208/230V (CH-RH09MASTWM-230VI / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 27.4 / HSPF2 12.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 9,000 BTU R-454B 208/230V (CH-PRO09MASTWM-230VI / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.8 / HSPF2 12.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 9,000 BTU R-454B 208/230V (CH-PRO09MASTWM-230VI / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 27.4 / HSPF2 12.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 9,000 BTU R-454B 208/230V (CH-RSH09-12MCT / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.6 / HSPF2 11.3
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 9,000 BTU R-454B 208/230V (CH-RSH09-12MCT / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.6 / HSPF2 12.1
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 6,000 BTU R-454B 115V (CH-RLS06MIA-115VI / CH-RLS06MIA-115VO)
- Capacity
- 9,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 21.5 / HSPF2 9
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 9,000 BTU R-454B 115V (CH-RLS09MIA-115VI / CH-RLS09MIA-115VO)
- Capacity
- 9,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 21.5 / HSPF2 9
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 9,000 BTU R-454B 208/230V (CH-RLS09MIA-230VI / CH-RLS09MIA-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.2 / HSPF2 9.1
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 6,000 BTU R-454B 115V (CH-R06OLVWM-115VI / CH-RES06-115VO)
- Capacity
- 9,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 24.5 / HSPF2 10.7
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 9,000 BTU R-454B 115V (CH-R09OLVWM-115VI / CH-RES09-115VO)
- Capacity
- 9,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 24.5 / HSPF2 10.7
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 9,000 BTU R-454B 208/230V (CH-R09MOLVWM-230VI / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24.6 / HSPF2 13
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 9,000 BTU R-454B 208/230V (CH-R09MOLVWM-230VI / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 26 / HSPF2 12.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 9,000 BTU R-454B 115V (CH-RB09OLVWM-115VI / CH-RES09-115VO)
- Capacity
- 9,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 24.5 / HSPF2 10.7
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 9,000 BTU R-454B 208/230V (CH-RB09MOLVWM-230VI / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24.6 / HSPF2 13
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 9,000 BTU R-454B 208/230V (CH-RB09MOLVWM-230VI / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 26 / HSPF2 12.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 9,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.1 / HSPF2 11.8
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 9,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 12.1
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 9,000 BTU R-454B 208/230V (CH-RS06-12MDT-MS / CH-RES09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19.5 / HSPF2 11
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 9,000 BTU R-454B 208/230V (CH-RS06-12MDT-MS / CH-RHP09-230VO)
- Capacity
- 9,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 12.5
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 12,000 BTU R-454B 208/230V (CH-RS06-12MDT-MS / CH-RES12-230VO)
- Capacity
- 11,500BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19 / HSPF2 10.2
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.1 / HSPF2 10.4
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.2 / HSPF2 11.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 12,000 BTU R-454B 208/230V (CH-RH12MASTWM-230VI / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.5 / HSPF2 10.6
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 12,000 BTU R-454B 208/230V (CH-RH12MASTWM-230VI / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.4 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 12,000 BTU R-454B 208/230V (CH-PRO12MASTWM-230VI / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.5 / HSPF2 10.6
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 12,000 BTU R-454B 208/230V (CH-PRO12MASTWM-230VI / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.4 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 12,000 BTU R-454B 208/230V (CH-RSH09-12MCT / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.1 / HSPF2 10.4
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 12,000 BTU R-454B 208/230V (CH-RSH09-12MCT / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.2 / HSPF2 11.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 12,000 BTU (115V)
- Capacity
- 12,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 21.2 / HSPF2 8.7
- Low ambient
- 5F
Data completeness: 90%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 12,000 BTU R-454B 208/230V (CH-RLS12MIA-230VI / CH-RLS12MIA-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.3 / HSPF2 9.1
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 12,000 BTU R-454B 115V (CH-R12OLVWM-115VI / CH-RES12-115VO)
- Capacity
- 12,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 23.2 / HSPF2 10.4
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 12,000 BTU R-454B 208/230V (CH-R12MOLVWM-230VI / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.1 / HSPF2 11.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 12,000 BTU R-454B 208/230V (CH-R12MOLVWM-230VI / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 12,000 BTU R-454B 115V (CH-RB12OLVWM-115VI / CH-RES12-115VO)
- Capacity
- 12,000BTU/h
- Voltage
- 115V
- Efficiency
- SEER2 23.2 / HSPF2 10.4
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 12,000 BTU R-454B 208/230V (CH-RB12MOLVWM-230VI / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.1 / HSPF2 11.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 12,000 BTU R-454B 208/230V (CH-RB12MOLVWM-230VI / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RES12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.1 / HSPF2 10
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23 / HSPF2 10
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 12,000 BTU R-454B 208/230V (CH-RS06-12MDT-MS / CH-RHP12-230VO)
- Capacity
- 12,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 10
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 16,000 BTU R-454B 208/230V (CH-RH18MCT / CH-RHP18-230VO)
- Capacity
- 16,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 12.3
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 16,000 BTU R-454B 208/230V (CH-RSH18MCT / CH-RHP18-230VO)
- Capacity
- 16,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 12.3
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 17,000 BTU R-454B 208/230V (CH-RSH18MCT1W / CH-RHP18-230VO)
- Capacity
- 16,700BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.6 / HSPF2 12.2
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 17,000 BTU R-454B 208/230V (CH-RH18MCT / CH-RES18-230VO)
- Capacity
- 16,800BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.7 / HSPF2 11.4
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 17,000 BTU R-454B 208/230V (CH-RSH18MCT / CH-RES18-230VO)
- Capacity
- 16,800BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.7 / HSPF2 11.4
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 17,000 BTU R-454B 208/230V (CH-RS18MDT-MS / CH-RES18-230VO)
- Capacity
- 17,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 10.5
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 17,000 BTU R-454B 208/230V (CH-RS18MDT-MS / CH-RHP18-230VO)
- Capacity
- 17,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 18 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 15,000 BTU R-454B 208/230V (CH-RH15MASTWM-230VI / CH-RHP15-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 11
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 18,000 BTU R-454B 208/230V (CH-RH18MASTWM-230VI / CH-RES18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.5 / HSPF2 10.8
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 18,000 BTU R-454B 208/230V (CH-RH18MASTWM-230VI / CH-RHP18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 11
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 15,000 BTU R-454B 208/230V (CH-PRO15MASTWM-230VI / CH-RHP15-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 11
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 18,000 BTU R-454B 208/230V (CH-PRO18MASTWM-230VI / CH-RES18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.5 / HSPF2 10.8
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 18,000 BTU R-454B 208/230V (CH-PRO18MASTWM-230VI / CH-RHP18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.4 / HSPF2 11
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Hyper Multi-Zone / Professional install
Cooper & Hunter Hyper Multi-Zone 3-Zone 18,000 BTU R-454B 208/230V (CH-R18MES-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25.1 / HSPF2 9.8
- Low ambient
- -13F
Data completeness: 95%Sourced Jul 2026
MIA Series / Professional install
Cooper & Hunter MIA 18,000 BTU R-454B 208/230V (CH-RLS18MIA-230VI / CH-RLS18MIA-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19.2 / HSPF2 9.6
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RES18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 11.1
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 18,000 BTU R-454B 208/230V (CH-R18MOLVWM-230VI / CH-RHP18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.7 / HSPF2 10.8
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 18,000 BTU R-454B 208/230V (CH-RB18MOLVWM-230VI / CH-RES18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 11.1
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 18,000 BTU R-454B 208/230V (CH-RB18MOLVWM-230VI / CH-RHP18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.7 / HSPF2 10.8
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
One-Way Cassette / Professional install
Cooper & Hunter One-Way Ceiling Cassette 18,000 BTU R-454B 208/230V (CH-RSH18MCT1W / CH-RES18-230VO)
- Capacity
- 18,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.2 / HSPF2 12.2
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Hyper Heat Multi-Zone / Professional install
Cooper & Hunter Hyper Heat Multi-Zone 3-Zone 19,000 BTU R-454B 208/230V (CH-RHP19M-230VO)
- Capacity
- 19,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25 / HSPF2 10.4
- Low ambient
- -22F
Data completeness: 95%Sourced Jul 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 24,000 BTU R-454B 208/230V (CH-R24MOLVWM-230VI / CH-RHP24-230VO)
- Capacity
- 23,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.3 / HSPF2 13.3
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 24,000 BTU R-454B 208/230V (CH-RB24MOLVWM-230VI / CH-RHP24-230VO)
- Capacity
- 23,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.3 / HSPF2 13.3
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 23,000 BTU R-454B 208/230V (CH-RH24MCT / CH-RHP24-230VO)
- Capacity
- 23,400BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.7 / HSPF2 11.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 23,000 BTU R-454B 208/230V (CH-RSH24MCT / CH-RHP24-230VO)
- Capacity
- 23,400BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.7 / HSPF2 11.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 24,000 BTU R-454B 208/230V (CH-RH24MCT / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22 / HSPF2 10.5
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 24,000 BTU R-454B 208/230V (CH-RH24MASTWM-230VI / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23 / HSPF2 11.7
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 24,000 BTU R-454B 208/230V (CH-RH24MASTWM-230VI / CH-RHP24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21 / HSPF2 13.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 24,000 BTU R-454B 208/230V (CH-PRO24MASTWM-230VI / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23 / HSPF2 11.7
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 24,000 BTU R-454B 208/230V (CH-PRO24MASTWM-230VI / CH-RHP24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21 / HSPF2 13.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 24,000 BTU R-454B 208/230V (CH-RSH24MCT / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22 / HSPF2 10.5
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
MIA Series / Professional install
Cooper & Hunter MIA 24,000 BTU R-454B 208/230V (CH-RLS24MIA-230VI / CH-RLS24MIA-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 18.7 / HSPF2 9.3
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 24,000 BTU R-454B 208/230V (CH-R24MOLVWM-230VI / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.5 / HSPF2 10
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Midnight Series / Professional install
Cooper & Hunter Olivia Midnight 24,000 BTU R-454B 208/230V (CH-RB24MOLVWM-230VI / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23.5 / HSPF2 10
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 24,000 BTU R-454B 208/230V (CH-RS24MDT-HS / CH-RES24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19 / HSPF2 11
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 24,000 BTU R-454B 208/230V (CH-RS24MDT-HS / CH-RHP24-230VO)
- Capacity
- 24,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19 / HSPF2 11.7
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Hyper Heat Multi-Zone / Professional install
Cooper & Hunter Hyper Heat Multi-Zone 4-Zone 28,000 BTU R-454B 208/230V (CH-RHP28M-230VO)
- Capacity
- 27,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 95%Sourced Jul 2026
Hyper Multi-Zone / Professional install
Cooper & Hunter Hyper Multi-Zone 4-Zone 28,000 BTU R-454B 208/230V (CH-R28MES-230VO)
- Capacity
- 27,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 25 / HSPF2 9.5
- Low ambient
- -13F
Data completeness: 95%Sourced Jul 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 30,000 BTU R-454B 208/230V (CH-RH30MASTWM-230VI / CH-REL30-230VO)
- Capacity
- 30,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.5 / HSPF2 9.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 30,000 BTU R-454B 208/230V (CH-PRO30MASTWM-230VI / CH-REL30-230VO)
- Capacity
- 30,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20.5 / HSPF2 9.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 30,000 BTU R-454B 208/230V (CH-R30MELVWM-230VI / CH-REL30-230VO)
- Capacity
- 30,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 22.3 / HSPF2 9
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 33,000 BTU R-454B 208/230V (CH-RH33HASTWM-230VI / CH-RHP33-230VO)
- Capacity
- 33,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19.5 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 33,000 BTU R-454B 208/230V (CH-PRO33HASTWM-230VI / CH-RHP33-230VO)
- Capacity
- 33,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19.5 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 33,000 BTU R-454B 208/230V (CH-R33HOLVWM-230VI / CH-RHP33-230VO)
- Capacity
- 33,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 10.5
- Low ambient
- -22F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 36,000 BTU R-454B 208/230V (CH-RH36LCCT / CH-R36LCU-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 10.3
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Astoria Series / Professional install
Cooper & Hunter Astoria 36,000 BTU R-454B 208/230V (CH-RH36MASTWM-230VI / CH-REL36-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19 / HSPF2 8.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Astoria Pro Series / Professional install
Cooper & Hunter Astoria Pro 36,000 BTU R-454B 208/230V (CH-PRO36MASTWM-230VI / CH-REL36-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19 / HSPF2 8.5
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 36,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-R36LCU-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 20 / HSPF2 10.3
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Hyper Heat Multi-Zone / Professional install
Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 23 / HSPF2 10.7
- Low ambient
- -22F
Data completeness: 95%Sourced Jul 2026
Hyper Multi-Zone / Professional install
Cooper & Hunter Hyper Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-R36MES-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 24 / HSPF2 9.5
- Low ambient
- -13F
Data completeness: 95%Sourced Jul 2026
Olivia Series / Professional install
Cooper & Hunter Olivia 36,000 BTU R-454B 208/230V (CH-R36MELVWM-230VI / CH-REL36-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 19.5 / HSPF2 9.1
- Low ambient
- -13F
Data completeness: 100%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 36,000 BTU R-454B 208/230V (CH-RS36LCDT-HS / CH-R36LCU-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 18.7 / HSPF2 10.2
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 36,000 BTU R-454B 208/230V (CH-RS36LCDT-HS / CH-RHP36LCU-230VO)
- Capacity
- 36,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 17.7 / HSPF2 11.1
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 37,000 BTU R-454B 208/230V (CH-RH36LCCT / CH-RHP36LCU-230VO)
- Capacity
- 36,600BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.2 / HSPF2 10.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO)
- Capacity
- 36,600BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 21.2 / HSPF2 10.6
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CH-RH48LCCT / CH-R48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 17.1 / HSPF2 9.8
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette / Professional install
Cooper & Hunter 4-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CH-RH48LCCT / CH-RHP48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 16.7 / HSPF2 10.8
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 48,000 BTU R-454B 208/230V (CH-RSH48LCCT / CH-R48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 17.1 / HSPF2 9.8
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Ceiling Cassette PRO / Professional install
Cooper & Hunter Ceiling Cassette PRO 48,000 BTU R-454B 208/230V (CH-RSH48LCCT / CH-RHP48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 16.7 / HSPF2 10.8
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 48,000 BTU R-454B 208/230V (CH-RS48LCDT-HS / CH-R48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 17.1 / HSPF2 9.8
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 48,000 BTU R-454B 208/230V (CH-RS48LCDT-HS / CH-RHP48LCU-230VO)
- Capacity
- 48,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 16.7 / HSPF2 10.8
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 55,000 BTU R-454B 208/230V (CH-RS60LCDT-HS / CH-RHP60LCU-230VO)
- Capacity
- 55,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 15.8 / HSPF2 10.4
- Low ambient
- -22F
Data completeness: 92%Sourced Aug 2026
Slim Duct / Professional install
Cooper & Hunter Slim Duct 58,000 BTU R-454B 208/230V (CH-RS60LCDT-HS / CH-R60LCU-230VO)
- Capacity
- 58,000BTU/h
- Voltage
- 230V
- Efficiency
- SEER2 17 / HSPF2 9.7
- Low ambient
- -13F
Data completeness: 92%Sourced Aug 2026