SplitAtlas

Cosmo / Cosmo Multi-Zone

Cosmo 36k R-32 208/230V 4-Zone Mini-Split

Certified capacity
36,000 BTU/h[2]
SEER2
21 SEER2[2]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The Cosmo Multi-Zone 4-zone is the cold-weather standout of the line: four rooms from one 208/230V outdoor unit on R-32, ENERGY STAR certified and AHRI cold-climate designated, at a certified nominal SEER2 of 21 (EER2 12, HSPF2 10). Its heating is the headline - rated 36000 BTU at 47F, 36000 at 17F, and 36000 at 5F, it holds its full rated output all the way down to 5F, which is exceptional capacity retention.

As always the certified SEER2 is the all-non-ducted nominal and depends on the heads you attach. Cosmo is a value brand sold through TOSOT Direct (TOSOT/Gree family), professionally installed and priced by quote.

4 zonesProfessional installCurrent

Refrigerant generation

R-32 - current-generation refrigerant

Need this installed?

Get installation quotes
Data completeness: 97%
Last sourced
Jul 29, 2026

SplitAtlas score

8.6 / 10

Methodology
Cooling efficiencyAbove average

(21.0 SEER2) among 36k systems

Heating efficiencyTop quartile

(10.0 HSPF2) among 36k systems

Cold-weather performanceTop quartile

(100% heat retained at 5F; -22 F heating floor) among 36k systems

WarrantyBottom quartile

(5 yr parts / 5 yr compressor) across the catalogue

Feature setBelow average

(4 verified features) across the catalogue

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

36,000BTU/hNon-Ducted Indoor Units[2]

Rated heating

36,000BTU/hNon-Ducted Indoor Units[2]

Buyer review snapshot

Best for / skip if

Best for

  • 4-zone projects in the 36k outdoor capacity class.

Install difficulty

Complex professional install
  • Electrical: 230V; MCA 30 A; breaker/fuse 45 A.
  • Line set: connection type not sourced; max 328 ft.
  • 4-zone condenser; indoor-head matching and branch layout are part of the job.

Alternatives

Availability and price context

We could not verify a current retail price for this model. These TOSOT/Cosmo multi-zone systems are professional-install equipment, so we link to contractor quotes rather than a retail price.

Source date

Model data sourced
Jul 29, 2026
Page reviewed
Jul 29, 2026
Source-backed records
4
Newest source retrieved
Jul 29, 2026

Warranty tiers

Warranty: 5 years parts and compressor as standard.

Review methodology

Model context

Install path
This is professional-install equipment; no verified current retail offer is attached.
Structured ratings
Certification: ENERGY STAR certified, ENERGY STAR cold-climate certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-32. Minimum heating ambient: -22 F.

Strengths

  • Full 36000 BTU heating output held from 47F all the way to 5F - flat, no deep-cold drop.
  • AHRI cold-climate designated and ENERGY STAR certified on current R-32 refrigerant.
  • Four zones from one outdoor unit and a single 208/230V circuit at a value price.

Weaknesses

  • Four-zone total capacity is shared; size to the condenser, not four full rooms.
  • Value-brand dealer/service network is thinner than the majors'.

Climate suitability

Minimum heating ambient
-22 F[1]
Rated heating at 5F
36,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 17F
36,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 47F
36,000 BTU/hNon-Ducted Indoor Units[2]

Specifications

Show
Manufacturer
Cosmo
Brand
Cosmo
Product line
Cosmo Multi-Zone
Model number
MZ-COSMO36/O
Indoor unit model
Indoor heads are selected separately on a multi-zone system
Outdoor unit model
MZ-COSMO36/O
Number of zones
4
Max indoor units
4 units[1]
Rated cooling capacity
36,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating capacity
36,000 BTU/hNon-Ducted Indoor Units[2]
Voltage
230 V[1]
MCA
30 A[1]
Maximum fuse or breaker size
45 A[1]
Breaker needed
not published
SEER2
21 SEER2Non-Ducted Indoor Units[2]
EER2
12 EER2Non-Ducted Indoor Units[2]
HSPF2 (Region 4)
10 HSPF2Non-Ducted Indoor Units[2]
HSPF2 (Region 5)
Certified per indoor-unit combination, not per outdoor unit
COP
not published
COP at 47F
3.56 COP[1]
COP at 5F
2.1 COPNon-Ducted Indoor Units[2]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
-22 F[1]
Maximum outdoor temperature
118 F[1]
Indoor noise range
Indoor heads are selected separately on a multi-zone system
Outdoor noise rating
63 dBA[1]
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
173.1 lb[1]
Refrigerant
R-32[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
328 ft[1]
Max line set per indoor
82 ft[1]
Maximum elevation difference
82 ft[1]
Max height between indoor units
82 ft[1]
Wi-Fi support
Indoor heads are selected separately on a multi-zone system
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
215708459Non-Ducted Indoor Units[2]
Warranty
Standard: 5 yr parts / 5 yr compressor (published Cosmo warranty terms). TOSOT Direct Cosmo Multi-Zone pages list a 5-year standard warranty for both compressor and parts.
Install path
Professional install
Retail price
These TOSOT/Cosmo multi-zone systems are professional-install equipment, so we link to contractor quotes rather than a retail price.
Available retailers
not published
Manual links
AHRI public detail 215708459, ENERGY STAR exact AHRI rows 215708459, Cosmo MZ user manual, 36,000 BTU Multi-Zones Split System / MZ-C36 current product page, Lead-gen/no-retail audit for MZ-COSMO36/O, TOSOT 2025 brochure Cosmo Multi-Zone outdoor condenser specs
Specification sheet
TOSOT 2025 brochure Cosmo Multi-Zone outdoor condenser specs
Last sourced date
Jul 29, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
30 A[1]
Breaker needed
not published
Maximum breaker size
45 A[1]
Maximum fuse size
45 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
not published
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
328 ft[1]
Max line set per indoor
82 ft[1]
Max height between indoor units
82 ft[1]
Indoor dimensions
Indoor heads are selected separately on a multi-zone system
Outdoor dimensions
40.16 x 16.81 x 32.52 in[1]
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
173.1 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Cosmo Multi-Zone 4-Zone 36,000 BTU R-32 208/230V (MZ-COSMO36/O) myself, or do I need a pro?
Cosmo Multi-Zone 4-Zone 36,000 BTU R-32 208/230V (MZ-COSMO36/O) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Cosmo Multi-Zone 4-Zone 36,000 BTU R-32 208/230V (MZ-COSMO36/O) keep heating in a cold winter?
The manufacturer publishes 36,000 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Cosmo Multi-Zone 4-Zone 36,000 BTU R-32 208/230V (MZ-COSMO36/O) need?
Published electrical requirements: 230 V voltage, 30 A minimum circuit ampacity, and 45 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 328 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Cosmo Multi-Zone 4-Zone 36,000 BTU R-32 208/230V (MZ-COSMO36/O) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 5 yr compressor (published Cosmo warranty terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. TOSOT Direct: TOSOT 2025 brochure Cosmo Multi-Zone outdoor condenser specsSourced - manufacturer technical document

    Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public detail for MZ-COSMO36/OSourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  3. ENERGY STAR: ENERGY STAR public certified air-source heat-pump rows for MZ-COSMO36/OSourced - Energy Star listing

    Covers performance_spec.energy_star_cold_climate, Energy Star status

  4. TOSOT Direct: TOSOT Direct Cosmo Multi-Zone product page warranty languageSourced - manufacturer product page

    Covers product_line.name, Legacy compressor warranty value, Legacy warranty value, Standard compressor warranty, Standard warranty conditions, Standard parts warranty and more

Last updated

Jul 29, 2026