Della / Optima Series Multi-Zone
Della Optima 18k R-454B 208/230V 2-Zone Mini-Split
The Della Optima 2-Zone 18k pairs two indoor heads with a single 208/230V outdoor unit in Della's budget-mid line. It posts a nominal SEER2 of 24, EER2 13, HSPF2 10.5, on current low-GWP R-454B refrigerant.
It is not ENERGY STAR certified and not AHRI cold-climate designated. Rated heating holds 20,000 BTU down to 17F, then falls to 16,000 BTU at 5F, so lean on backup heat in a hard winter.
Professional installation required; dealer-quoted.
Refrigerant generation
R-454B - current-generation refrigerant
Need this installed?
Get installation quotes
Image: Della
- Last sourced
- Jul 28, 2026
SplitAtlas score
8.5 / 10
(24.0 SEER2) among 18k systems
(10.5 HSPF2) among 18k systems
(5F certified capacity: 80% of the 47F rating; -13 F heating floor) among 18k systems
(4 verified features) across the catalogue
(7 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Best-fit use cases
A two-room home in a mild-to-moderate climate chasing low upfront cost, with buyers who need certification or true cold-climate heat better served by the Optima Pro CloudAir or R-32 Vita.
Buyer review snapshot
Best for / skip if
Best for
- 2-zone projects in the 18k outdoor capacity class.
- High-efficiency shortlists; SEER2 is 24.
Install difficulty
- Electrical: 230V; MCA 16 A; breaker/fuse 25 A.
- Line set: Flared line connections; precharged 25 ft; max 131 ft.
- 2-zone condenser; indoor-head matching and branch layout are part of the job.
Alternatives
- ACiQ Multi-Zone Extreme Series 2-Zone 18,000 BTU R-454B 208/230V (ACIQ-18Z-HH-M3C)
8.9 score / 19k / SEER2 25 / -22 F heating floor / 230V
Exact destination at HVACDirect: $2,549.99, checked Jul 29, 2026
- ACiQ Multi-Zone Standard Series 2-Zone 18,000 BTU R-454B 208/230V (ES-18Z-M3C)
8.6 score / 18k / SEER2 25.1 / -13 F heating floor / 230V
Exact destination at HVACDirect: $1,499.99, checked Jul 29, 2026
Availability and price context
This system needs a professional install, so its real price is an installed quote that depends on your home. We don't link to a listing for this exact model; get installation quotes to price it.
Source date
- Model data sourced
- Jul 28, 2026
- Page reviewed
- Jul 28, 2026
- Source-backed records
- 4
- Newest source retrieved
- Jul 28, 2026
Warranty tiers
No Base or Registered tier is established for scoring.
Model context
- Install path
- This is professional-install equipment; price it with an installed quote.
- Structured ratings
- Certification: ENERGY STAR certified. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.
Strengths
- Two zones from one condenser for a couple of rooms.
- Nominal SEER2 24 / EER2 13 / HSPF2 10.5, strong for a budget line.
- Value-priced ductless from an online-focused brand.
Weaknesses
- Not ENERGY STAR certified and not AHRI cold-climate designated.
- Heating falls off in deep cold, down to 16,000 BTU at 5F.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Certified heating at 5F
- 16,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 17F
- 20,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 47F
- 20,000 BTU/hNon-Ducted Indoor Units[3]
Specifications
ShowHide
- Manufacturer
- Della
- Brand
- Della
- Product line
- Optima Series Multi-Zone
- Model number
- 048-TLP-MODU-1D2
- Indoor unit model
- Depends on the indoor units you choose
- Outdoor unit model
- 048-TLP-MODU-1D2
- Number of zones
- 2
- Max indoor units
- 2 units[2]
- Rated cooling capacity
- 18,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating capacity
- 20,000 BTU/hNon-Ducted Indoor Units[3]
- Voltage
- 230 V[2]
- MCA
- 16 A[2]
- Maximum fuse or breaker size
- 25 A[2]
- Breaker needed
- not published
- SEER2
- 24 SEER2Non-Ducted Indoor Units[3]
- EER2
- 13 EER2Non-Ducted Indoor Units[3]
- HSPF2 (Region 4)
- 10.5 HSPF2Non-Ducted Indoor Units[3]
- HSPF2 (Region 5)
- Varies by indoor-unit combination
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 2 COPNon-Ducted Indoor Units[3]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- not published
- Maximum outdoor temperature
- 131 F[1]
- Indoor noise range
- Depends on the indoor units you choose
- Outdoor noise rating
- 58 dBA[2]
- Indoor weight
- Depends on the indoor units you choose
- Outdoor weight
- 92.6 lb[2]
- Refrigerant
- R-454B[3]
- Refrigerant charge
- 60.01 oz[2]
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in per zone liquid / 3/8 in per zone; adapters for larger indoor units when required suction
- Included line-set length
- Depends on the indoor units you choose
- Maximum line-set length
- 131 ft[2]
- Max line set per indoor
- 85 ft[2]
- Maximum elevation difference
- 49 ft[2]
- Max height between indoor units
- not published
- Wi-Fi support
- Depends on the indoor units you choose
- Energy Star status
- Not ENERGY STAR certified[4]
- AHRI certification number
- 218472764Non-Ducted Indoor Units[3]
- Warranty
- Della warranty terms vary by registration and installation context; product pages expose Warranty Registration / Warranty Policy links.
- Install path
- Professional install
- Retail price
- Installed quote only
- Available retailers
- not published
- Manual links
- AHRI public detail 218472764, Della 048-TLP MODU Series Manual, ENERGY STAR exact row 218472764, Della Optima Series Multi-Zone installation manual for 048-TLP-MODU-1D2, Della Optima Series Multi-Zone official product page example for 048-TLP-MODU-1D2, Della Optima Series Multi-Zone manual technical tables for 048-TLP-MODU-1D2
- Specification sheet
- Della Optima Series Multi-Zone manual technical tables for 048-TLP-MODU-1D2
- Last sourced date
- Jul 28, 2026
Compatible indoor units
This is an outdoor unit. You choose its indoor heads separately - up to the maximum this condenser supports - and you can mix room sizes and styles across the zones. The models below are the heads this unit is documented to pair with.
Ceiling cassette air handlers
9k, 12k
Model numbers
- 9k: 048-CC-9K2V-IN
- 12k: 048-CC-12K2V-IN
Concealed duct air handlers
9k, 12k
Model numbers
- 9k: 048-DC-9K2V-IN
- 12k: 048-DC-12K2V-IN
Wall-mounted air handlers
9k, 12k
Model numbers
- 9k: 048-TL-9K2VB-20S-IN
- 9k: 048-TP-9K2V-24S-C-IN
- 9k: 048-TP-9K2V-24S-IN
- 12k: 048-TL-12K2VB-23S-IN
- 12k: 048-TP-12K2V-24S-C-IN
- 12k: 048-TP-12K2V-24S-IN
Sizing note: do not just add up the rooms. Multi-zone condensers have a maximum total connected capacity, and connecting more head capacity than the unit is rated for is a common installer mistake that hurts efficiency and comfort. Match total head capacity to the condenser's rating.
Installation considerations
ShowHide
- Liquid line
- 1/4 in per zone[2]
- Suction line
- 3/8 in per zone; adapters for larger indoor units when required[2]
- Line connection type
- Flared line connections[2]
- Precharged length
- 25 ft[2]
- Included line-set length
- Depends on the indoor units you choose
- Maximum line-set length
- 131 ft[2]
- Max line set per indoor
- 85 ft[2]
- Max height between indoor units
- not published
- Indoor dimensions
- Depends on the indoor units you choose
- Outdoor dimensions
- 36.50 x 14.96 x 27.52 in[2]
- Indoor weight
- Depends on the indoor units you choose
- Outdoor weight
- 92.6 lb[2]
- Drain size
- not published
Related systems and guides
- More Della systems
- Della Optima Pro CloudAir 18k R-454B 208/230V Mini-Split
- Della Serena 18k R-32 208/230V Mini-Split
- Della Optima Pro 18k R-454B 208/230V Mini-Split
- Della Serena CloudAir 18k R-32 208/230V Mini-Split
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Della mini split review: is Della any good?
- The best 18,000 BTU mini splits of 2026
- The best multi-zone mini splits of 2026
- The best 2-zone (dual-zone) mini splits of 2026
- How to size a multi-zone mini split
- Not every multi-zone condenser lets you mix head types
- How much does a multi-zone mini split cost?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- One room won't heat or cool on a multi-zone mini split
- Mini split not heating
- Mini split indoor unit freezing up
- Your mini split is showing a refrigerant leak code
- Mini split remote not working
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Della Optima Series Multi-Zone 2-Zone 18,000 BTU R-454B 208/230V (048-TLP-MODU-1D2) myself, or do I need a pro?
- Della Optima Series Multi-Zone 2-Zone 18,000 BTU R-454B 208/230V (048-TLP-MODU-1D2) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Della Optima Series Multi-Zone 2-Zone 18,000 BTU R-454B 208/230V (048-TLP-MODU-1D2) keep heating in a cold winter?
- The AHRI/ENERGY STAR certification lists 16,000 BTU/h of heating capacity at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Della Optima Series Multi-Zone 2-Zone 18,000 BTU R-454B 208/230V (048-TLP-MODU-1D2) need?
- Published electrical requirements: 230 V voltage, 16 A minimum circuit ampacity, and 25 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length from the outdoor unit to one indoor head is 85 ft. The combined piping limit across all heads is 131 ft. The outdoor unit's factory charge covers up to 25 ft of line; longer runs need added refrigerant. Measure the planned routing before ordering.
Data sources
ShowHide
- Della: Della Optima Series Multi-Zone official product-page evidence for 048-TLP-MODU-1D2Sourced - manufacturer product page
Covers brand.dealer_installation_policy, Minimum outdoor heating temperature, Maximum outdoor temperature, product_line.name, Warranty notes
- Della: Della Optima Series Multi-Zone official manual technical table for 048-TLP-MODU-1D5Sourced - manufacturer technical document
Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Manufacturer wire notes and more
- AHRI certificate #218472764 - search the AHRI DirectorySourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR record for AHRI #218472764 - search ENERGY STARSourced - Energy Star listing
Covers performance_spec.energy_star_cold_climate, Energy Star status
- Della 048-TLP MODU Series ManualSourced - manual
Covers Manual links
Last updated
Jul 28, 2026