Della / Serena Series
Della Serena 9k R-32 208/230V Mini-Split
The Serena 9k on 230V is a small, efficient unit that barely tapers in the cold. It rates SEER2 22, EER2 13.5, and HSPF2 9.5, heating 9,300 BTU/h at 47F and holding 8,800 BTU/h at 5F. It suits a small room where steady low-temperature output is wanted on a fixed circuit.
Refrigerant generation
R-32 - current-generation refrigerant
Paid link
$680 / Fresh price - checked Jul 24, 2026
Need this installed?
Get installation quotes
Image: Della
- Last sourced
- Jul 24, 2026
SplitAtlas score
8.2 / 10
(22.0 SEER2) among <=9k systems
(9.5 HSPF2) among <=9k systems
(94.6% heat retained at 5F; 5 F heating floor) among <=9k systems
(DIY-marketed; 25 ft precharged; 16 ft included line set) across the catalogue
(3 verified features) across the catalogue
($680 median retail) among <=9k systems
(4 manuals; spec sheet) across the catalogue
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- High-efficiency shortlists; SEER2 is 22.
Install difficulty
- Electrical: 230V; breaker/fuse 15 A.
- Line set: Flared line connections; precharged 25 ft; included 16 ft.
Alternatives
- Blueridge XS6 Max Efficiency 9,000 BTU R-454B 208/230V (BXS6A09WM0 / BXS6A09UC0)
8.9 score / 9k / SEER2 33.3 / -22 F heating floor / 230V
Exact destination at Alpine Home Air: $1,689.00, checked Jul 24, 2026
- Senville ELITE 9,000 BTU R-454B 208/230V (SENE-09EL-IHH / SENE-09EL-OH)
8.8 score / 9k / SEER2 33.3 / -22 F heating floor / 187-253V
Exact destination at Senville: $1,599.99, checked Jul 24, 2026
- ACiQ Extreme 9,000 BTU R-454B 208/230V (ACIQ-09W-HH-MD / ACIQ-09ZPL-HP230C)
8.8 score / 9k / SEER2 27.4 / -22 F heating floor / 230V
Exact destination at HVACDirect: $1,499.99, checked Jul 26, 2026
Availability and price context
- Verified current price: $679.96 at Della; availability in_stock; checked Jul 24, 2026.
Source date
- Model data sourced
- Jul 24, 2026
- Page reviewed
- Jul 24, 2026
- Source-backed records
- 3
- Newest source retrieved
- Jul 24, 2026
Strengths
- Holds 8,800 BTU/h at 5F, well above its 7,900 BTU/h at 17F, for strong cold-weather output.
- EER2 13.5 leads the Serena family on peak cooling efficiency.
- Low-GWP R-32 refrigerant on a standard 230V circuit.
Weaknesses
- Not ENERGY STAR certified, unlike the larger Serena units, which limits rebate options.
- Della's newer value-brand support network is thinner than that of premium legacy names.
Climate suitability
- Minimum heating ambient
- 5 F[1]
- Rated heating at 5F
- 8,800 BTU/h[2]
- Rated heating at 17F
- 7,900 BTU/h[2]
- Rated heating at 47F
- 9,300 BTU/h[2]
Specifications
ShowHide
- Manufacturer
- Della
- Brand
- Della
- Product line
- Serena Series
- Model number
- 048-MS-9K2VR-22S-M-IN indoor / 048-MS-9K2VR-22S-M-OUT outdoor
- Indoor unit model
- 048-MS-9K2VR-22S-M-IN
- Outdoor unit model
- 048-MS-9K2VR-22S-M-OUT
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 9,000 BTU/h[2]
- Rated heating capacity
- 9,300 BTU/h[2]
- Voltage
- 230 V[1]
- MCA
- not published - manufacturer specifies 15 A breaker
- Maximum fuse or breaker size
- 15 A[1]
- Breaker needed
- 15 A[1]
- SEER2
- 22 SEER2[2]
- EER2
- 13.5 EER2[2]
- HSPF2 (Region 4)
- 9.5 HSPF2[2]
- HSPF2 (Region 5)
- not published
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 1.98 COP[2]
- Minimum outdoor heating temperature
- 5 F[1]
- Minimum outdoor cooling temperature
- not published
- Maximum outdoor temperature
- 125 F[1]
- Indoor noise range
- not published
- Outdoor noise rating
- not published
- Indoor weight
- 17.6 lb[1]
- Outdoor weight
- 51.81 lb[1]
- Refrigerant
- R-32[2]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- 16 ft[1]
- Maximum line-set length
- not published
- Max line set per indoor
- not published
- Maximum elevation difference
- not published
- Max height between indoor units
- not published
- Wi-Fi support
- supported[1]
- Energy Star status
- Not ENERGY STAR certified[3]
- AHRI certification number
- 218154697[2]
- Warranty
- not published
- Install path
- Professional install / DIY-marketed
- Marketing install label
- DIY-marketed
- Retail price
- $679.96
- Available retailers
- Della
- Manual links
- AHRI Appendix M1 public detail record 218154697, DELLA Serena Series 9000 BTU 22 SEER2 Mini-Split Heat Pump AC - Up to 400 Sq.Ft. official product page, Serena Series installation and operation guide, Serena 9,000 BTU Della product-page specifications
- Specification sheet
- Serena 9,000 BTU Della product-page specifications
- Last sourced date
- Jul 24, 2026
Retail purchase context
Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure
Paid link
$680 / Fresh price - checked Jul 24, 2026
Electrical requirements
ShowHide
- Voltage
- 230 V[1]
- Voltage range
- 208/230V[1]
- Phase
- 1[1]
- Frequency
- not published
- MCA
- not published - manufacturer specifies 15 A breaker
- Breaker needed
- 15 A[1]
- Maximum breaker size
- not published
- Maximum fuse size
- 15 A[1]
- Maximum cooling current
- not published
- Maximum heating current
- not published
- Manufacturer wire notes
- not published
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 3/8 in[1]
- Line connection type
- Flared line connections[1]
- Precharged length
- 25 ft[1]
- Included line-set length
- 16 ft[1]
- Maximum line-set length
- not published
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- 30.24 in W x 11.77 in H x 7.87 in D[1]
- Outdoor dimensions
- 27.76 in W x 20.87 in H x 10.98 in D[1]
- Indoor weight
- 17.6 lb[1]
- Outdoor weight
- 51.81 lb[1]
- Drain size
- not published
Related systems and guides
- More Della systems
- Della 9k model
- Della 230 V option
- Della 9k model
- Della Vario Series 9k 115V
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Della mini split review: is Della any good?
- The best 9,000 BTU mini splits of 2026
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- R-32 vs R-454B: the mini split refrigerant change explained
- Mini split for a hot upstairs
- Mini splits for an ADU or tiny home
- What the symbols on your mini split remote mean
- Mini split remote not working
- Mini split Wi-Fi not connecting
- Mini split lights blinking
- Mini split not cooling
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Della Serena 9,000 BTU R-32 208/230V (048-MS-9K2VR-22S-M-IN / 048-MS-9K2VR-22S-M-OUT) myself, or do I need a pro?
- Della Serena 9,000 BTU R-32 208/230V (048-MS-9K2VR-22S-M-IN / 048-MS-9K2VR-22S-M-OUT) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Della Serena 9,000 BTU R-32 208/230V (048-MS-9K2VR-22S-M-IN / 048-MS-9K2VR-22S-M-OUT) keep heating in a cold winter?
- The manufacturer publishes 8,800 BTU/h of heating output at 5F. Rated heating operation extends down to 5 F. Certified heating efficiency is 9.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Della Serena 9,000 BTU R-32 208/230V (048-MS-9K2VR-22S-M-IN / 048-MS-9K2VR-22S-M-OUT) need?
- Published electrical requirements: 230 V voltage, not published - manufacturer specifies 15 A breaker minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
Data sources
ShowHide
- Della: DELLA Serena Series 9000 BTU 22 SEER2 Mini-Split Heat Pump AC - Up to 400 Sq.Ft. official product pageSourced - manufacturer technical document
Covers Breaker needed, Maximum fuse size, Phase, Voltage, Voltage range, Included line-set length and more
- AHRI certificate #218154697 - search the AHRI DirectorySourced - AHRI directory
Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more
- ENERGY STAR: ENERGY STAR exact row check for AHRI 215864147Sourced - Energy Star listing
Covers Energy Star status
Last updated
Jul 24, 2026