Della / Vita Series Multi-Zone
Della Vita 28k R-32 208/230V 3-Zone Mini-Split
The Della Vita 3-Zone 28k runs three indoor heads off one 208/230V outdoor unit on current R-32 refrigerant. It posts a nominal SEER2 of 22, EER2 11.2, HSPF2 10, is ENERGY STAR certified and AHRI cold-climate designated.
Rated heating falls off in the cold, from 28,000 BTU at 47F to 22,000 at 17F and 21,000 at 5F. Professional installation required; dealer-quoted.
Refrigerant generation
R-32 - current-generation refrigerant
Need this installed?
Get installation quotes
Image: Della
- Last sourced
- Jul 28, 2026
SplitAtlas score
8.3 / 10
(22.0 SEER2) among 24k systems
(10.0 HSPF2) among 24k systems
(75% heat retained at 5F; -13 F heating floor) among 24k systems
(6 verified features) across the catalogue
(7 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- 3-zone projects in the 30k outdoor capacity class.
- High-efficiency shortlists; SEER2 is 22.
Install difficulty
- Electrical: 230V; MCA 16 A; breaker/fuse 25 A.
- Line set: Flared line connections; precharged 25 ft; max 197 ft.
- 3-zone condenser; indoor-head matching and branch layout are part of the job.
Availability and price context
We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.
Source date
- Model data sourced
- Jul 28, 2026
- Page reviewed
- Jul 28, 2026
- Source-backed records
- 4
- Newest source retrieved
- Jul 28, 2026
Warranty tiers
Warranty: Della warranty terms vary by registration and installation context; product pages expose Warranty Registration / Warranty Policy links.
Model context
- Install path
- This is professional-install equipment; no verified current retail offer is attached.
- Structured ratings
- Certification: ENERGY STAR certified, ENERGY STAR cold-climate certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-32. Minimum heating ambient: -13 F.
Strengths
- Three zones with a certified nominal SEER2 22 / EER2 11.2 / HSPF2 10.
- Value-priced certified three-zone from an online-focused brand.
Weaknesses
- Rated heating falls off in deep cold, down to 21,000 BTU at 5F.
- 28,000 BTU across three zones is modest per room; size each head.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Rated heating at 5F
- 21,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 17F
- 22,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 47F
- 28,000 BTU/hNon-Ducted Indoor Units[3]
Specifications
ShowHide
- Manufacturer
- Della
- Brand
- Della
- Product line
- Vita Series Multi-Zone
- Model number
- 048-TCQ-MODU-1D3
- Indoor unit model
- Indoor heads are selected separately on a multi-zone system
- Outdoor unit model
- 048-TCQ-MODU-1D3
- Number of zones
- 3
- Max indoor units
- 3 units[2]
- Rated cooling capacity
- 28,000 BTU/hNon-Ducted Indoor Units[3]
- Rated heating capacity
- 28,000 BTU/hNon-Ducted Indoor Units[3]
- Voltage
- 230 V[2]
- MCA
- 16 A[2]
- Maximum fuse or breaker size
- 25 A[2]
- Breaker needed
- not published
- SEER2
- 22 SEER2Non-Ducted Indoor Units[3]
- EER2
- 11.2 EER2Non-Ducted Indoor Units[3]
- HSPF2 (Region 4)
- 10 HSPF2Non-Ducted Indoor Units[3]
- HSPF2 (Region 5)
- Certified per indoor-unit combination, not per outdoor unit
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 2 COPNon-Ducted Indoor Units[3]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- not published
- Maximum outdoor temperature
- 131 F[1]
- Indoor noise range
- Indoor heads are selected separately on a multi-zone system
- Outdoor noise rating
- 61 dBA[2]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 97 lb[2]
- Refrigerant
- R-32[3]
- Refrigerant charge
- 60 oz[2]
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in per zone liquid / 3/8 in per zone suction
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 197 ft[2]
- Max line set per indoor
- 98 ft[2]
- Maximum elevation difference
- 49 ft[2]
- Max height between indoor units
- not published
- Wi-Fi support
- Indoor heads are selected separately on a multi-zone system
- Energy Star status
- ENERGY STAR certified[4]
- AHRI certification number
- 218470993Non-Ducted Indoor Units[3]
- Warranty
- Della warranty terms vary by registration and installation context; product pages expose Warranty Registration / Warranty Policy links.
- Install path
- Professional install
- Retail price
- We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.
- Available retailers
- not published
- Manual links
- AHRI public detail 218470993, Della 048-TCQ MODU Series Manual, ENERGY STAR exact row 218470993, Della Vita Series Multi-Zone installation manual for 048-TCQ-MODU-1D3, Della Vita Series Multi-Zone official product page example for 048-TCQ-MODU-1D3, HVACDirect exact-offer audit for 048-TCQ-MODU-1D3, Della Vita Series Multi-Zone manual technical tables for 048-TCQ-MODU-1D3
- Specification sheet
- Della Vita Series Multi-Zone manual technical tables for 048-TCQ-MODU-1D3
- Last sourced date
- Jul 28, 2026
Compatible indoor units
This is an outdoor unit. You choose its indoor heads separately - up to the maximum this condenser supports - and you can mix room sizes and styles across the zones. The models below are the heads this unit is documented to pair with.
Wall-mounted air handlers
9k, 12k, 18k
Model numbers
- 9k: 048-TC-9K2VR-IN
- 12k: 048-TC-12K2VR-IN
- 18k: 048-TC-18K2VR-IN
Sizing note: do not just add up the rooms. Multi-zone condensers have a maximum total connected capacity, and connecting more head capacity than the unit is rated for is a common installer mistake that hurts efficiency and comfort. Match total head capacity to the condenser's rating.
Installation considerations
ShowHide
- Liquid line
- 1/4 in per zone[2]
- Suction line
- 3/8 in per zone[2]
- Line connection type
- Flared line connections[2]
- Precharged length
- 25 ft[2]
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 197 ft[2]
- Max line set per indoor
- 98 ft[2]
- Max height between indoor units
- not published
- Indoor dimensions
- Indoor heads are selected separately on a multi-zone system
- Outdoor dimensions
- 36.50 x 14.96 x 27.52 in[2]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 97 lb[2]
- Drain size
- not published
Related systems and guides
- More Della systems
- Senville AURA Multizone 27k 230V
- GREE Vireo+ Ultra 28k 230V
Previous generation
- Della 27k model
- Della Econo Series 35k 230V
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Della mini split review: is Della any good?
- The best multi-zone mini splits of 2026
- The best 3-zone mini splits of 2026
- How to size a multi-zone mini split
- Not every multi-zone condenser lets you mix head types
- How much does a multi-zone mini split cost?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- One room won't heat or cool on a multi-zone mini split
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split Wi-Fi not connecting
- Mini split remote not working
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Della Vita Series Multi-Zone 3-Zone 28,000 BTU R-32 208/230V (048-TCQ-MODU-1D3) myself, or do I need a pro?
- Della Vita Series Multi-Zone 3-Zone 28,000 BTU R-32 208/230V (048-TCQ-MODU-1D3) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Della Vita Series Multi-Zone 3-Zone 28,000 BTU R-32 208/230V (048-TCQ-MODU-1D3) keep heating in a cold winter?
- The manufacturer publishes 21,000 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Della Vita Series Multi-Zone 3-Zone 28,000 BTU R-32 208/230V (048-TCQ-MODU-1D3) need?
- Published electrical requirements: 230 V voltage, 16 A minimum circuit ampacity, and 25 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 197 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
Data sources
ShowHide
- Della: Della Vita Series Multi-Zone official product-page evidence for 048-TCQ-MODU-1D3Sourced - manufacturer product page
Covers brand.dealer_installation_policy, Minimum outdoor heating temperature, Maximum outdoor temperature, product_line.name, Warranty notes
- Della: Della Vita Series Multi-Zone official manual technical table for 048-TCQ-MODU-1D5Sourced - manufacturer technical document
Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Manufacturer wire notes and more
- AHRI certificate #218470993 - search the AHRI DirectorySourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR record for AHRI #218470993 - search ENERGY STARSourced - Energy Star listing
Covers performance_spec.energy_star_cold_climate, Energy Star status
- Della 048-TCQ MODU Series ManualSourced - manual
Covers Manual links
Last updated
Jul 28, 2026