Certified capacity
14,700 BTU/h[3]
SEER2
22.4 SEER2[3]
Heating floor
-15 F[2]
Voltage
230 V[1]
Install path
Professional install

The Panasonic EXTERIOS Z 15k matches the ClimaPure XZ 15k: SEER2 22.4, EER2 13.35, HSPF2 12 on R-32, heating to 17,500 BTU at 17F and 15,300 BTU at 5F. Same outdoor and certified ratings, different indoor head - choose on features and price.

1 zoneProfessional installCurrent

Refrigerant generation

R-32 - current-generation refrigerant

Need this installed?

Get installation quotes
Panasonic EXTERIOS Z Series 15,000 BTU R-32 208/230V (CS-Z15AKUAW / CU-XZ15AKUAC)

Image: Panasonic

Data completeness: 95%
Last sourced
Jul 24, 2026

SplitAtlas score

9.3 / 10

Methodology
Cooling efficiencyAbove average

(22.4 SEER2) among 12k systems

Heating efficiencyTop 10%

(12.0 HSPF2) among 12k systems

Cold-weather performanceTop 10%

(100% heat retained at 5F; -15 F heating floor) among 12k systems

NoiseTop 10%

(-46 dBA indoor min / 50 dBA outdoor) among 12k systems

Feature setTop quartile

(6 verified features) across the catalogue

Documentation & partsBelow average

(8 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

14,700BTU/h[3]

Rated heating

14,700BTU/h[3]

Buyer review snapshot

Best for / skip if

Best for

  • High-efficiency shortlists; SEER2 is 22.4.

Install difficulty

Professional install
  • Electrical: 230V; MCA 15 A; breaker/fuse 20 A.
  • Line set: connection type not sourced; precharged 25 ft; max 66 ft.

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-24.

Source date

Model data sourced
Jul 24, 2026
Page reviewed
Jul 23, 2026
Source-backed records
4
Newest source retrieved
Jul 24, 2026

Review methodology

Model context

Install path
This is professional-install equipment; no verified current retail offer is attached.

Strengths

  • HSPF2 12 - excellent seasonal heating efficiency; identical to the XZ 15k.
  • Cold-climate heating boost to 17,500 BTU at 17F; current R-32 refrigerant.
  • Panasonic dealer support.

Weaknesses

  • Same performance as the ClimaPure XZ 15k - decide on indoor features and price.

Climate suitability

Minimum heating ambient
-15 F[2]
Rated heating at 5F
15,300 BTU/h[3]
Rated heating at 17F
17,500 BTU/h[3]
Rated heating at 47F
14,700 BTU/h[3]

Specifications

Show
Manufacturer
Panasonic
Brand
Panasonic
Product line
EXTERIOS Z Series
Model number
CS-Z15AKUAW indoor / CU-XZ15AKUAC outdoor
Indoor unit model
CS-Z15AKUAW
Outdoor unit model
CU-XZ15AKUAC
Number of zones
1
Max indoor units
not published
Rated cooling capacity
14,700 BTU/h[3]
Rated heating capacity
14,700 BTU/h[3]
Voltage
230 V[1]
MCA
15 A[2]
Maximum fuse or breaker size
20 A[2]
Breaker needed
not published
SEER2
22.4 SEER2[3]
EER2
13.35 EER2[3]
HSPF2 (Region 4)
12 HSPF2[3]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
2.14 COP[3]
Minimum outdoor heating temperature
-15 F[2]
Minimum outdoor cooling temperature
0 F[2]
Maximum outdoor temperature
115 F[2]
Indoor noise range
30-46 dB(A)[2]
Outdoor noise rating
50 dBA[2]
Indoor weight
24 lb[1]
Outdoor weight
11 lb[1]
Refrigerant
R-32[3]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 1/2 in suction
Included line-set length
Panasonic current R-32 high-wall professional-install sources publish refrigerant piping size, maximum length, and precharged length, but no included line set.
Maximum line-set length
66 ft[2]
Max line set per indoor
not published
Maximum elevation difference
49.2 ft[2]
Max height between indoor units
not published
Wi-Fi support
not supported[1]
Energy Star status
ENERGY STAR certified[4]
AHRI certification number
215387073[3]
Warranty
not published
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-24.
Available retailers
not published
Manual links
AHRI certificate 215387073, AHRI public directory record 215387073, ENERGY STAR exact Panasonic row for CS-Z15AKUAW / CU-XZ15AKUAC, HVACDirect exact Panasonic search summary for CS-Z15AKUAW / CU-XZ15AKUAC, Panasonic EXTERIOS Z Series 15k installation manual, Panasonic EXTERIOS Z Series 15k product page extracted text, Panasonic EXTERIOS Z Series 15k product page snapshot, Panasonic EXTERIOS Z Series 15k system submittal
Specification sheet
Panasonic EXTERIOS Z Series 15k product page snapshot
Last sourced date
Jul 24, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
15 A[2]
Breaker needed
not published
Maximum breaker size
20 A[2]
Maximum fuse size
20 A[2]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[2]
Suction line
1/2 in[2]
Line connection type
not published
Precharged length
25 ft[2]
Included line-set length
Panasonic current R-32 high-wall professional-install sources publish refrigerant piping size, maximum length, and precharged length, but no included line set.
Maximum line-set length
66 ft[2]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
34-9/32 x 9-1/32 x 11-5/8 in[1]
Outdoor dimensions
34-15/32 x 12-5/8 x 27-5/8 in[1]
Indoor weight
24 lb[1]
Outdoor weight
11 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Panasonic EXTERIOS Z Series 15,000 BTU R-32 208/230V (CS-Z15AKUAW / CU-XZ15AKUAC) myself, or do I need a pro?
Panasonic EXTERIOS Z Series 15,000 BTU R-32 208/230V (CS-Z15AKUAW / CU-XZ15AKUAC) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Panasonic EXTERIOS Z Series 15,000 BTU R-32 208/230V (CS-Z15AKUAW / CU-XZ15AKUAC) keep heating in a cold winter?
The manufacturer publishes 15,300 BTU/h of heating output at 5F. Rated heating operation extends down to -15 F. Certified heating efficiency is 12 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Panasonic EXTERIOS Z Series 15,000 BTU R-32 208/230V (CS-Z15AKUAW / CU-XZ15AKUAC) need?
Published electrical requirements: 230 V voltage, 15 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 66 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.

Data sources

Show
  1. Panasonic Corporation of North America: Panasonic EXTERIOS Z Series 15k manufacturer product pageSourced - manufacturer product page

    Covers Frequency, Phase, Voltage, Voltage range, Indoor dimensions, Indoor weight and more

  2. Panasonic Corporation of North America: Panasonic EXTERIOS Z Series 15k system submittalSourced - manufacturer technical document

    Covers Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Indoor noise range, Liquid line size, Maximum elevation difference and more

  3. Air-Conditioning, Heating, and Refrigeration Institute: AHRI public detail 215387073 for CS-Z15AKUAW / CU-XZ15AKUACSourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more

  4. U.S. Environmental Protection Agency: ENERGY STAR exact Panasonic row for CS-Z15AKUAW / CU-XZ15AKUACSourced - Energy Star listing

    Covers Energy Star status

Last updated

Jul 23, 2026