Pioneer / Quantum Ultra
Pioneer Quantum Ultra 23k Ceiling Cassette R-454B 208/230V Mini-Split
The Pioneer Quantum Ultra 23k ceiling cassette is the strongest CYT cassette: 22.5 SEER2, 10.4 HSPF2, 25,000 BTU heating at 47F, and 19,100 BTU at 5F from a 25A breaker.
Refrigerant generation
R-454B - current-generation refrigerant
Paid link
$2,286 / Fresh price - checked Aug 2, 2026
Need this installed?
Get installation quotes- Last sourced
- Aug 2, 2026
SplitAtlas score
8.3 / 10
(22.5 SEER2) among 24k systems
(10.4 HSPF2) among 24k systems
(76.4% heat retained at 5F; -13 F heating floor) among 24k systems
(34 dBA indoor min / 54 dBA outdoor) among 24k systems
(6 verified features) across the catalogue
($2,286 median retail) among 24k systems
(4 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- High-efficiency shortlists; SEER2 is 22.5.
Install difficulty
- Electrical: 230V; MCA 25 A; breaker/fuse 25 A.
Alternatives
- GREE Sapphire R32 24,000 BTU R-32 208/230V (SAP24HP230V1R32AH / SAP24HP230V1R32AO)
8.8 score / 22k / SEER2 27 / -22 F heating floor / 230V
Exact destination at HVACDirect: $4,318.00, checked Jul 24, 2026
- Blueridge XS3 High Efficiency 24,000 BTU R-454B 208/230V (BXAFA24WM0 / BXS3A24SC0)
8.8 score / 24k / SEER2 23 / -13 F heating floor / 230V
Exact destination at Alpine Home Air: $1,939.00, checked Jul 24, 2026
- Senville ELITE 24,000 BTU R-454B 208/230V (SENE-24EL-IHH / SENE-24EL-OH)
8.7 score / 24k / SEER2 25 / -22 F heating floor / 187-253V
Exact destination at Senville: $2,099.99, checked Jul 24, 2026
Availability and price context
- Verified current price: $2,286.00 at Pioneer; availability in_stock; checked Aug 2, 2026.
Source date
- Model data sourced
- Aug 2, 2026
- Page reviewed
- Aug 12, 2026
- Source-backed records
- 3
- Newest source retrieved
- Aug 2, 2026
Warranty tiers
Warranty: up to 10-year Quantum Ultra warranty coverage
Model context
- Structured ratings
- Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.
Strengths
- Best efficiency/capacity balance in the Pioneer CYT cassette group.
- ENERGY STAR certified with a complete official product record.
- 23,000 BTU cooling and broad ceiling distribution suit larger open rooms.
- 34 to 50 dB indoor sound range is reasonable for this output.
Weaknesses
- 5F heat still falls below the 47F rating.
- Larger cassette panel and outdoor unit require more installation coordination.
- More expensive than Senville's largest four-way cassette in captured direct prices.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Rated heating at 5F
- 19,100 BTU/h[2]
- Rated heating at 17F
- 22,000 BTU/h[2]
- Rated heating at 47F
- 25,000 BTU/h[2]
Specifications
ShowHide
- Manufacturer
- Pioneer
- Brand
- Pioneer
- Product line
- Quantum Ultra
- Model number
- CT024GLSILCFHG indoor / YN024GLSI24RPG outdoor
- Indoor unit model
- CT024GLSILCFHG
- Outdoor unit model
- YN024GLSI24RPG
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 23,000 BTU/h[2]
- Rated heating capacity
- 25,000 BTU/h[2]
- Voltage
- 230 V[1]
- MCA
- 25 A[1]
- Maximum fuse or breaker size
- 25 A[1]
- Breaker needed
- 25 A[1]
- SEER2
- 22.5 SEER2[2]
- EER2
- 11.7 EER2[2]
- HSPF2 (Region 4)
- 10.4 HSPF2[2]
- HSPF2 (Region 5)
- 9.4 HSPF2[1]
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 2 COP[2]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- 5 F[1]
- Maximum outdoor temperature
- 131 F[1]
- Indoor noise range
- ( Turbo/Hi/Med/Lo/Mute): 50 / 47 / 43 / 38 / 34 dB(A)[1]
- Outdoor noise rating
- 54 dBA[1]
- Indoor weight
- 51.8 lb[1]
- Outdoor weight
- 104.7 lb[1]
- Refrigerant
- R-454B[2]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 5/8 in suction
- Included line-set length
- Pioneer full-set product page offers multiple no-kit and line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.
- Max line set per indoor
- not published
- Maximum elevation difference
- Pioneer product pages in the cached collection did not publish a single maximum elevation for these full-set variants.
- Max height between indoor units
- not published
- Wi-Fi support
- supported[1]
- Energy Star status
- ENERGY STAR certified[3]
- AHRI certification number
- 217048761[2]
- Warranty
- up to 10-year Quantum Ultra warranty coverage
- Install path
- Professional install
- Retail price
- $2,286.00
- Available retailers
- Pioneer
- Manual links
- AHRI Active row 217048761, 8-Way Ceiling Cassette installation requirements from Pioneer product technical table, Pioneer® Quantum Ultra™ 23,000 BTU 22.5 SEER2 230V 8-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump Full Set official product page, Pioneer® Quantum Ultra™ 23,000 BTU 22.5 SEER2 230V 8-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump Full Set official product-page technical table
- Specification sheet
- Pioneer® Quantum Ultra™ 23,000 BTU 22.5 SEER2 230V 8-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump Full Set official product-page technical table
- Last sourced date
- Aug 2, 2026
Retail purchase context
Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure
Paid link
$2,286 / Fresh price - checked Aug 2, 2026
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 5/8 in[1]
- Line connection type
- not published
- Precharged length
- not published
- Included line-set length
- Pioneer full-set product page offers multiple no-kit and line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- 33"-1/8 x 33"-3/4 x 10"-3/4 Inches[1]
- Outdoor dimensions
- 38"-1/2 x 16"-5/8 x 31"-5/8 Inches[1]
- Indoor weight
- 51.8 lb[1]
- Outdoor weight
- 104.7 lb[1]
- Drain size
- not published
Related systems and guides
- More Pioneer systems
- Pioneer sibling model
- Cooper & Hunter 230 V option
- Pioneer 230 V option
- Pioneer Diamante Essenza 23k 230V
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Pioneer mini split review: is Pioneer any good?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- R-32 vs R-454B: the mini split refrigerant change explained
- Pioneer mini split not cooling
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split Wi-Fi not connecting
- Mini split short cycling
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Pioneer Quantum Ultra 8-Way Ceiling Cassette 23,000 BTU R-454B 208/230V (CT024GLSILCFHG / YN024GLSI24RPG) myself, or do I need a pro?
- Pioneer Quantum Ultra 8-Way Ceiling Cassette 23,000 BTU R-454B 208/230V (CT024GLSILCFHG / YN024GLSI24RPG) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Pioneer Quantum Ultra 8-Way Ceiling Cassette 23,000 BTU R-454B 208/230V (CT024GLSILCFHG / YN024GLSI24RPG) keep heating in a cold winter?
- The manufacturer publishes 19,100 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10.4 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Pioneer Quantum Ultra 8-Way Ceiling Cassette 23,000 BTU R-454B 208/230V (CT024GLSILCFHG / YN024GLSI24RPG) need?
- Published electrical requirements: 230 V voltage, 25 A minimum circuit ampacity, and 25 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
Data sources
ShowHide
- Pioneer / Parker Davis HVAC International, Inc.: Pioneer® Quantum Ultra™ 48,000 BTU 17 SEER2 230V Slim-Duct Ceiling Concealed Mini-Split Air Conditioner Inverter Heat Pump Full SetSourced - manufacturer product page
Covers Breaker needed, Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active form-factor row 217048761Sourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR: ENERGY STAR exact row check for AHRI 218010994Sourced - Energy Star listing
Covers Energy Star status
Last updated
Aug 12, 2026