Senville AURA 17k Concealed Ducted R-454B 208/230V Mini-Split

Certified capacity
17,000 BTU/h[3]
SEER2
18 SEER2[3]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The Senville AURA 18k-class concealed ducted system certifies at 17,000 BTU cooling, 19,000 BTU heating at 47F, and 18,000 BTU at 5F, but efficiency steps down to 18 SEER2 and 10.5 HSPF2.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Paid link

$1,600 / Fresh price - checked Aug 2, 2026

Check price at Senville

Need this installed?

Get installation quotes
Data completeness: 90%
Last sourced
Aug 2, 2026

SplitAtlas score

8.0 / 10

Methodology
Cooling efficiencyBottom quartile

(18.0 SEER2) among 18k systems

Heating efficiencyAbove average

(10.5 HSPF2) among 18k systems

Cold-weather performanceAbove average

(94.7% heat retained at 5F; -22 F heating floor) among 18k systems

NoiseBottom quartile

(32 dBA indoor min / 59 dBA outdoor) among 18k systems

WarrantyBelow average

(5 yr parts / 10 yr compressor) across the catalogue

Feature setAbove average

(6 verified features) across the catalogue

Price-to-performanceBelow average

($1,600 median retail) among 18k systems

Documentation & partsBelow average

(5 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

Key ratings

Rated cooling

17,000BTU/h[3]

Rated heating

19,000BTU/h[3]

Buyer review snapshot

Install difficulty

Professional install
  • Electrical: 230V; MCA 19 A; breaker/fuse 20 A.
  • Line set: connection type not sourced; precharged 25 ft; included 16 ft; max 98.4 ft.

Alternatives

Availability and price context

  • Verified current price: $1,599.99 at Senville; availability in_stock; checked Aug 2, 2026.

Source date

Model data sourced
Aug 2, 2026
Page reviewed
Aug 12, 2026
Source-backed records
4
Newest source retrieved
Aug 2, 2026

Warranty tiers

Warranty: 5 years parts and 10 years compressor as standard.

Review methodology

Model context

Structured ratings
Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.

Strengths

  • Meaningfully more ducted capacity than the 12k without jumping to the 24k cabinet.
  • 5F heat rating remains strong for cold-climate use.
  • Published indoor sound range of 32.0 to 40.0 dB is usable for a hidden ducted head.
  • 20A breaker class is easier to place than larger ducted equipment.

Weaknesses

  • 18 SEER2 is the lowest Senville efficiency number in this batch.
  • 54.45 lb indoor unit and ductwork need real framing coordination.
  • Captured sources still miss exact line sizes and cooling ambient range.

Climate suitability

Minimum heating ambient
-22 F[1]
Rated heating at 5F
18,000 BTU/h[3]
Rated heating at 17F
15,000 BTU/h[3]
Rated heating at 47F
19,000 BTU/h[3]

Specifications

Show
Manufacturer
Senville
Brand
Senville
Product line
AURA
Model number
SENA-18HF-IDG indoor / SENA-18HF-OG outdoor
Indoor unit model
SENA-18HF-IDG
Outdoor unit model
SENA-18HF-OG
Number of zones
1
Max indoor units
not published
Rated cooling capacity
17,000 BTU/h[3]
Rated heating capacity
19,000 BTU/h[3]
Voltage
230 V[1]
MCA
19 A[1]
Maximum fuse or breaker size
20 A[1]
Breaker needed
not published
SEER2
18 SEER2[3]
EER2
12 EER2[3]
HSPF2 (Region 4)
10.5 HSPF2[3]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
2 COP[3]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
not published
Maximum outdoor temperature
not published
Indoor noise range
40.0 / 39.0 / 38.0 / 32.0 dB[1]
Outdoor noise rating
59 dBA[1]
Indoor weight
54.45 lb[1]
Outdoor weight
99.87 lb[1]
Refrigerant
R-454B[3]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
not published
Included line-set length
16 ft[1]
Maximum line-set length
98.4 ft[2]
Max line set per indoor
not published
Maximum elevation difference
65.6 ft[2]
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[4]
AHRI certification number
215735302[3]
Warranty
Standard: 5 yr parts / 10 yr compressor (published warranty terms). 10-year compressor / 5-year parts
Install path
Professional install
Retail price
$1,599.99
Available retailers
Senville
Manual links
AHRI Active row 215735302, Senville AURA installation manual, 18000 BTU Concealed Duct Air Conditioner - Heat Pump - SENA/18HF/IDSenville official product page, Senville concealed duct service manual, 18000 BTU Concealed Duct Air Conditioner - Heat Pump - SENA/18HF/IDSenville official product-page specification table
Specification sheet
18000 BTU Concealed Duct Air Conditioner - Heat Pump - SENA/18HF/IDSenville official product-page specification table
Last sourced date
Aug 2, 2026

Retail purchase context

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at Senville

$1,600 / Fresh price - checked Aug 2, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
187-253[1]
Phase
single-phase[1]
Frequency
60 Hz[1]
MCA
19 A[1]
Breaker needed
not published
Maximum breaker size
20 A[1]
Maximum fuse size
20 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
not published
Suction line
not published
Line connection type
not published
Precharged length
25 ft[1]
Included line-set length
16 ft[1]
Maximum line-set length
98.4 ft[2]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
34.65 x 26.54 x 8.27 in[1]
Outdoor dimensions
35.04 x 13.46 x 26.50 in[1]
Indoor weight
54.45 lb[1]
Outdoor weight
99.87 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Senville AURA Concealed Ducted 17,000 BTU R-454B 208/230V (SENA-18HF-IDG / SENA-18HF-OG) myself, or do I need a pro?
Senville AURA Concealed Ducted 17,000 BTU R-454B 208/230V (SENA-18HF-IDG / SENA-18HF-OG) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Senville AURA Concealed Ducted 17,000 BTU R-454B 208/230V (SENA-18HF-IDG / SENA-18HF-OG) keep heating in a cold winter?
The manufacturer publishes 18,000 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Senville AURA Concealed Ducted 17,000 BTU R-454B 208/230V (SENA-18HF-IDG / SENA-18HF-OG) need?
Published electrical requirements: 230 V voltage, 19 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 98.4 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Senville AURA Concealed Ducted 17,000 BTU R-454B 208/230V (SENA-18HF-IDG / SENA-18HF-OG) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 10 yr compressor (published warranty terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. Senville: 18000 BTU Concealed Duct Air Conditioner - Heat Pump - SENA/18HF/IDSenvilleSourced - manufacturer product page

    Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Voltage and more

  2. Senville: Senville AURA installation manualSourced - manufacturer technical document

    Covers Maximum elevation difference, Maximum line-set length

  3. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active form-factor row 215735302Sourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  4. ENERGY STAR: ENERGY STAR exact row check for AHRI 218010994Sourced - Energy Star listing

    Covers Energy Star status

Last updated

Aug 12, 2026