SplitAtlas

TOSOT / Multi Ultra Heat

TOSOT Multi Ultra Heat 55k R-32 208/230V 6-Zone Mini-Split

Certified capacity
55,000 BTU/h[2]
SEER2
21 SEER2[2]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The TOSOT Multi Ultra Heat 6-zone is the top of the line: up to six rooms from one 208/230V outdoor unit on R-32, ENERGY STAR certified, at a certified nominal SEER2 of 21 (EER2 11.65, HSPF2 10). Unlike the smaller Multi Ultra Heat units, the 6-zone is not AHRI cold-climate designated, so treat it as broad-coverage rather than a hard-freeze specialist.

Its certified heating is rated 55000 BTU at 47F, 41000 at 17F, and 36400 at 5F, tapering through deep cold. That certified SEER2 is the all-non-ducted nominal and depends on the heads you attach.

TOSOT is a value brand (TOSOT/Gree family) sold on tosot.com, professionally installed and priced by quote.

6 zonesProfessional installCurrent

Refrigerant generation

R-32 - current-generation refrigerant

Need this installed?

Get installation quotes
TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO)

Image: TOSOT

Data completeness: 97%
Last sourced
Jul 29, 2026

SplitAtlas score

8.0 / 10

Methodology
Cooling efficiencyAbove average

(21.0 SEER2) among >36k systems

Heating efficiencyBelow average

(10.0 HSPF2) among >36k systems

Cold-weather performanceBottom quartile

(5F certified capacity: 66.2% of the 47F rating; -22 F heating floor) among >36k systems

WarrantyTop quartile

(10 yr parts / 10 yr compressor) across the catalogue

Feature setBottom quartile

(3 verified features) across the catalogue

Documentation & partsTop quartile

(6 manuals; spec sheet; 14 error-code rows) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

55,000BTU/hNon-Ducted Indoor Units[2]

Rated heating

55,000BTU/hNon-Ducted Indoor Units[2]

Buyer review snapshot

Best for / skip if

Best for

  • 6-zone projects in the 54k outdoor capacity class.

Install difficulty

Complex professional install
  • Electrical: 230V; MCA 37.5 A; breaker/fuse 40 A.
  • Line set: connection type not sourced; precharged 197 ft; max 394 ft.
  • 6-zone condenser; indoor-head matching and branch layout are part of the job.

Availability and price context

This TOSOT/Cosmo multi-zone system is sold through dealers, so its price comes as an installed quote that depends on your home. Get installation quotes to price it.

Source date

Model data sourced
Jul 29, 2026
Page reviewed
Jul 29, 2026
Source-backed records
5
Newest source retrieved
Jul 29, 2026

Warranty tiers

Base
10 yr parts / 10 yr compressor - equipment sold and installed by licensed professionals in residential applications

The score uses Base. Additional published terms are shown for reference and not counted in the score.

Review methodology

Model context

Install path
This is professional-install equipment; price it with an installed quote.

Strengths

  • Six zones of coverage and 55000 BTU of 47F heating from a single outdoor unit.
  • ENERGY STAR certified on current R-32 refrigerant at a value price.
  • One 208/230V circuit for up to six rooms.

Weaknesses

  • Not AHRI cold-climate designated, and heating tapers to 36400 BTU at 5F - size for deep cold carefully.
  • Six-zone total capacity is shared and modest per room; size heads carefully.

Climate suitability

Minimum heating ambient
-22 F[1]
Certified heating at 5F
36,400 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 17F
41,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 47F
55,000 BTU/hNon-Ducted Indoor Units[2]

Specifications

Show
Manufacturer
TOSOT
Brand
TOSOT
Product line
Multi Ultra Heat
Model number
TMH60D32MO
Indoor unit model
Depends on the indoor units you choose
Outdoor unit model
TMH60D32MO
Number of zones
6
Max indoor units
6 units[1]
Rated cooling capacity
55,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating capacity
55,000 BTU/hNon-Ducted Indoor Units[2]
Voltage
230 V[1]
MCA
37.5 A[1]
Maximum fuse or breaker size
40 A[1]
Breaker needed
not published
SEER2
21 SEER2Non-Ducted Indoor Units[2]
EER2
11.65 EER2Non-Ducted Indoor Units[2]
HSPF2 (Region 4)
10 HSPF2Non-Ducted Indoor Units[2]
HSPF2 (Region 5)
Varies by indoor-unit combination
COP
not published
COP at 47F
not published
COP at 5F
1.9 COPNon-Ducted Indoor Units[2]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
-22 F[1]
Maximum outdoor temperature
118 F[1]
Indoor noise range
Depends on the indoor units you choose
Outdoor noise rating
54 dBA[1]
Indoor weight
Depends on the indoor units you choose
Outdoor weight
225 lb[1]
Refrigerant
R-32[2]
Refrigerant charge
112.88 oz[1]
Manufacturer coverage
not published
Line-set size
1/4 in ports A-E; allowable indoor units 1-6 liquid / 1/2 in x 2 and 3/8 in x 3; allowable indoor units 1-6 suction
Included line-set length
Depends on the indoor units you choose
Maximum line-set length
394 ft[1]
Max line set per indoor
82 ft[1]
Maximum elevation difference
82 ft[1]
Max height between indoor units
82 ft[1]
Wi-Fi support
Depends on the indoor units you choose
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
217994526Non-Ducted Indoor Units[2]
Warranty
Base: 10 yr parts / 10 yr compressor (equipment sold and installed by licensed professionals in residential applications). Score uses Base.. TOSOT warranty information lists a standard 10-year compressor warranty and 10-year parts warranty for equipment sold and installed by licensed professionals in residential applications.
Install path
Professional install
Retail price
Installed quote only
Available retailers
not published
Manual links
AHRI public detail 217994526, ENERGY STAR exact AHRI rows 217994526, TOSOT Multi Ultra Heat / TMH60D32MO current product page, TMH60D32MO TOSOT Multi Ultra Heat submittal, TOSOT warranty information
Specification sheet
TMH60D32MO TOSOT Multi Ultra Heat submittal
Last sourced date
Jul 29, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
37.5 A[1]
Breaker needed
not published
Maximum breaker size
40 A[1]
Maximum fuse size
40 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in ports A-E; allowable indoor units 1-6[1]
Suction line
1/2 in x 2 and 3/8 in x 3; allowable indoor units 1-6[1]
Line connection type
not published
Precharged length
197 ft[1]
Included line-set length
Depends on the indoor units you choose
Maximum line-set length
394 ft[1]
Max line set per indoor
82 ft[1]
Max height between indoor units
82 ft[1]
Indoor dimensions
Depends on the indoor units you choose
Outdoor dimensions
38-55/64 x 16-7/32 x 49-49/64 in[1]
Indoor weight
Depends on the indoor units you choose
Outdoor weight
225 lb[1]
Drain size
not published

Frequently asked questions

Can I install the TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO) myself, or do I need a pro?
TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO) keep heating in a cold winter?
The AHRI/ENERGY STAR certification lists 36,400 BTU/h of heating capacity at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO) need?
Published electrical requirements: 230 V voltage, 37.5 A minimum circuit ampacity, and 40 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length from the outdoor unit to one indoor head is 82 ft. The combined piping limit across all heads is 394 ft. The outdoor unit's factory charge covers up to 197 ft of line; longer runs need added refrigerant. Measure the planned routing before ordering.
What warranty does the TOSOT Multi Ultra Heat 6-Zone 55,000 BTU R-32 208/230V (TMH60D32MO) carry?
The manufacturer publishes these warranty tiers: Base: 10 yr parts / 10 yr compressor (equipment sold and installed by licensed professionals in residential applications). Score uses Base.. Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. TOSOT: TMH60D32MO TOSOT Multi Ultra Heat submittalSourced - manufacturer technical document

    Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. AHRI certificate #217994526 - search the AHRI DirectorySourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  3. ENERGY STAR: ENERGY STAR exact row check for AHRI 215735288Sourced - Energy Star listing

    Covers performance_spec.energy_star_cold_climate, Energy Star status

  4. TOSOT: TOSOT Multi Ultra Heat / TMH60D32MO current product evidenceSourced - manufacturer product page

    Covers product_line.name

  5. TOSOT: TOSOT warranty informationSourced - manufacturer product page

    Covers Legacy compressor warranty value, Legacy warranty value, Base compressor warranty, Base warranty conditions, Base parts warranty, Warranty notes

Last updated

Jul 29, 2026