Cooper & Hunter / Ceiling Cassette PRO
Cooper Hunter Ceiling Cassette PRO 37k Hyper Ceiling Cassette 208/230V Mini-Split
The hyper light-commercial PRO cassette certifies at 36,600 BTU cooling and 37,000 heating, with 21.2 SEER2 and 10.6 HSPF2, rated to -22F.
Here the hyper unit is better on both axes - more efficient in cooling than the standard version as well as far more capable in the cold. If the building operates through winter, there is no real argument for the standard version.
Refrigerant generation
R-454B - current-generation refrigerant
Need this installed?
Get installation quotes- Last sourced
- Aug 2, 2026
SplitAtlas score
8.8 / 10
(21.2 SEER2) among >36k systems
(10.6 HSPF2) among >36k systems
(5F certified capacity: 100% of the 47F rating; -22 F heating floor) among >36k systems
(5 yr parts / 7 yr compressor) across the catalogue
(7 verified features) across the catalogue
(6 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Buyer review snapshot
Install difficulty
- Electrical: 230V; MCA 38 A; breaker/fuse 40 A.
- Line set: Flared line connections; precharged 25 ft; max 246 ft.
Availability and price context
This system needs a professional install, so its real price is an installed quote that depends on your home. We don't link to a listing for this exact model; get installation quotes to price it.
Source date
- Model data sourced
- Aug 2, 2026
- Page reviewed
- Aug 2, 2026
- Source-backed records
- 3
- Newest source retrieved
- Aug 2, 2026
Warranty tiers
- Registered
- 5 yr parts / 7 yr compressor - licensed-technician installation and registration terms
The score uses Registered. Additional published terms are shown for reference and not counted in the score.
Model context
- Structured ratings
- Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.
Strengths
- 21.2 SEER2 and a -22F rating - better than the standard version on both counts.
- 36,600 BTU of cooling at light-commercial scale.
Weaknesses
- 37,000 BTU heating, marginally below the standard version's 38,000.
- Significant structural and design requirements at three tons.
Climate suitability
- Minimum heating ambient
- -22 F[1]
- Certified heating at 5F
- 37,000 BTU/h[2]
- Rated heating at 17F
- 30,600 BTU/h[2]
- Rated heating at 47F
- 37,000 BTU/h[2]
Specifications
ShowHide
- Manufacturer
- Cooper & Hunter
- Brand
- Cooper & Hunter
- Product line
- Ceiling Cassette PRO
- Model number
- CH-RSH36LCCT indoor / CH-RHP36LCU-230VO outdoor
- Indoor unit model
- CH-RSH36LCCT
- Outdoor unit model
- CH-RHP36LCU-230VO
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 36,600 BTU/h[2]
- Rated heating capacity
- 37,000 BTU/h[2]
- Voltage
- 230 V[1]
- MCA
- 38 A[1]
- Maximum fuse or breaker size
- 40 A[1]
- Breaker needed
- not published
- SEER2
- 21.2 SEER2[2]
- EER2
- 12 EER2[2]
- HSPF2 (Region 4)
- 10.6 HSPF2[2]
- HSPF2 (Region 5)
- not published
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 1.95 COP[2]
- Minimum outdoor heating temperature
- -22 F[1]
- Minimum outdoor cooling temperature
- -22 F[1]
- Maximum outdoor temperature
- 122 F[1]
- Indoor noise range
- not published
- Outdoor noise rating
- 64.5 dBA[1]
- Indoor weight
- not published
- Outdoor weight
- 206.57 lb[1]
- Refrigerant
- R-454B[2]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 3/8 in liquid / 3/4 in suction
- Included line-set length
- C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
- Maximum line-set length
- 246 ft[1]
- Max line set per indoor
- not published
- Maximum elevation difference
- 98.4 ft[1]
- Max height between indoor units
- not published
- Wi-Fi support
- supported[1]
- Energy Star status
- ENERGY STAR certified[2]
- AHRI certification number
- 215864192[2]
- Warranty
- Registered: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). Score uses Registered.. 7-year compressor and 5-year parts limited warranty with licensed-technician installation and registration terms.
- Install path
- Professional install
- Retail price
- Installed quote only
- Available retailers
- not published
- Manual links
- AHRI Active public directory row 215864192, Installation manual R454B Ceiling Cassette PRO, Cooper & Hunter Multi R installation manual, Cooper & Hunter Ceiling Cassette PRO official product pages for CH-RSH36LCCT, Owner's manual R454B Ceiling Cassette PRO, Cooper & Hunter support-material submittal for CH-RHP36LCU-230VO + CH-RSH36LCCT
- Specification sheet
- Cooper & Hunter support-material submittal for CH-RHP36LCU-230VO + CH-RSH36LCCT
- Last sourced date
- Aug 2, 2026
Electrical requirements
ShowHide
- Voltage
- 230 V[1]
- Voltage range
- 208/230V[1]
- Phase
- 1[1]
- Frequency
- 60 Hz[1]
- MCA
- 38 A[1]
- Breaker needed
- not published
- Maximum breaker size
- 40 A[1]
- Maximum fuse size
- 40 A[1]
- Maximum cooling current
- not published
- Maximum heating current
- not published
- Manufacturer wire notes
- Field wiring per C&H support-material submittal and local electrical code.[1]
Installation considerations
ShowHide
- Liquid line
- 3/8 in[1]
- Suction line
- 3/4 in[1]
- Line connection type
- Flared line connections[1]
- Precharged length
- 25 ft[1]
- Included line-set length
- C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
- Maximum line-set length
- 246 ft[1]
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- not published
- Outdoor dimensions
- 38.58 x 16.34 x 38.39 in[1]
- Indoor weight
- not published
- Outdoor weight
- 206.57 lb[1]
- Drain size
- not published
Related systems and guides
- More Cooper & Hunter systems
- Cooper Hunter Ceiling Cassette 37k Hyper R-454B 208/230V Mini-Split
- Della Vita 38k R-32 208/230V 4-Zone Mini-Split
- Cooper Hunter Ceiling Cassette 48k R-454B 208/230V Mini-Split
- TOSOT Multi Ultra Heat 36k R-32 208/230V 4-Zone Mini-Split
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Cooper & Hunter mini split review: is Cooper & Hunter any good?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- R-32 vs R-454B: the mini split refrigerant change explained
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split remote not working
- Your mini split is showing a refrigerant leak code
- Mini split Wi-Fi not connecting
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO) myself, or do I need a pro?
- Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO) keep heating in a cold winter?
- The AHRI/ENERGY STAR certification lists 37,000 BTU/h of heating capacity at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.6 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO) need?
- Published electrical requirements: 230 V voltage, 38 A minimum circuit ampacity, and 40 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 246 ft. The outdoor unit's factory charge covers up to 25 ft of line; longer runs need added refrigerant. Measure the planned routing before ordering.
- What warranty does the Cooper & Hunter Ceiling Cassette PRO 37,000 BTU R-454B 208/230V (CH-RSH36LCCT / CH-RHP36LCU-230VO) carry?
- The manufacturer publishes these warranty tiers: Registered: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). Score uses Registered.. Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.
Data sources
ShowHide
- Cooper & Hunter: Cooper & Hunter support-material submittal for CH-R36LCU-230VO + CH-RSH36LCCTSourced - manufacturer technical document
Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active Cooper & Hunter form-factor row 215864231Sourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Energy Star status and more
- Cooper & Hunter: Cooper & Hunter Multi R installation manual limited warranty sectionSourced - manufacturer technical document
Covers Legacy compressor warranty value, Legacy warranty value, Registered compressor warranty, Registered warranty conditions, Registered parts warranty, Warranty notes
Last updated
Aug 2, 2026
