Friedrich / Floating Air Pro X
Friedrich Floating Air Pro X 42k R-454B 208/230V 5-Zone Mini-Split
The Floating Air Pro X 5-zone covers five rooms from one 208/230V outdoor unit. It carries current R-454B refrigerant and a certified nominal SEER2 of 22 (EER2 12, HSPF2 9.5), and it is ENERGY STAR certified and AHRI cold-climate designated.
As with any multi-zone, that certified figure is the all-non-ducted nominal; your real efficiency depends on the heads you attach. Heating is rated at 48000 BTU at 47F, 28200 at 17F, and 36000 at 5F - output is lower in deep cold than at 47F, so plan capacity for your coldest design day.
Friedrich is an established American brand installed by professional dealers and priced by quote.
Refrigerant generation
R-454B - current-generation refrigerant
Need this installed?
Get installation quotes
Image: Shop Appliances
- Last sourced
- Jul 29, 2026
SplitAtlas score
8.4 / 10
(22.0 SEER2) among >36k systems
(9.5 HSPF2) among >36k systems
(75% heat retained at 5F; -13 F heating floor) among >36k systems
(7 yr parts / 10 yr compressor) across the catalogue
(4 verified features) across the catalogue
(8 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- 5-zone projects in the 42k outdoor capacity class.
- High-efficiency shortlists; SEER2 is 22.
Install difficulty
- Electrical: 230V; MCA 36 A; breaker/fuse 40 A.
- Line set: connection type not sourced; precharged 125 ft; max 262 ft.
- 5-zone condenser; indoor-head matching and branch layout are part of the job.
Availability and price context
We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-29.
Source date
- Model data sourced
- Jul 29, 2026
- Page reviewed
- Jul 29, 2026
- Source-backed records
- 3
- Newest source retrieved
- Jul 29, 2026
Warranty tiers
Warranty: 7 years parts and 10 years compressor if the system is registered.
Model context
- Install path
- This is professional-install equipment; no verified current retail offer is attached.
- Structured ratings
- Certification: ENERGY STAR certified and ENERGY STAR cold-climate certified. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.
Strengths
- Five zones from one outdoor unit and one 208/230V circuit.
- Certified nominal SEER2 22 / EER2 12 / HSPF2 9.5, ENERGY STAR certified.
- Strong heating output of 48000 BTU at 47F and 36000 at 5F, AHRI cold-climate designated.
- Current R-454B refrigerant from an established, quality-focused American brand.
Weaknesses
- Five-zone total capacity is shared; size to the condenser, not five full rooms.
- Heating output is lower in deep cold (28200 at 17F and 36000 at 5F versus 48000 at 47F), and pricing is dealer-quoted only.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Rated heating at 5F
- 36,000 BTU/hNon-Ducted Indoor Units[2]
- Rated heating at 17F
- 28,200 BTU/hNon-Ducted Indoor Units[2]
- Rated heating at 47F
- 48,000 BTU/hNon-Ducted Indoor Units[2]
Specifications
ShowHide
- Manufacturer
- Friedrich
- Brand
- Friedrich
- Product line
- Floating Air Pro X
- Model number
- FPHMR42A3D
- Indoor unit model
- Indoor heads are selected separately on a multi-zone system
- Outdoor unit model
- FPHMR42A3D
- Number of zones
- 5
- Max indoor units
- 5 units[1]
- Rated cooling capacity
- 42,000 BTU/hNon-Ducted Indoor Units[2]
- Rated heating capacity
- 48,000 BTU/hNon-Ducted Indoor Units[2]
- Voltage
- 230 V[1]
- MCA
- 36 A[1]
- Maximum fuse or breaker size
- 40 A[1]
- Breaker needed
- not published
- SEER2
- 22 SEER2Non-Ducted Indoor Units[2]
- EER2
- 12 EER2Non-Ducted Indoor Units[2]
- HSPF2 (Region 4)
- 9.5 HSPF2Non-Ducted Indoor Units[2]
- HSPF2 (Region 5)
- Certified per indoor-unit combination, not per outdoor unit
- COP
- not published
- COP at 47F
- 3.6 COP[1]
- COP at 5F
- 1.92 COPNon-Ducted Indoor Units[2]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- 5 F[1]
- Maximum outdoor temperature
- 125 F[1]
- Indoor noise range
- Indoor heads are selected separately on a multi-zone system
- Outdoor noise rating
- 64 dBA[1]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 172 lb[1]
- Refrigerant
- R-454BNon-Ducted Indoor Units[2]
- Refrigerant charge
- 105.8 oz[1]
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 262 ft[1]
- Max line set per indoor
- 82 ft[1]
- Maximum elevation difference
- 49 ft[1]
- Max height between indoor units
- not published
- Wi-Fi support
- Indoor heads are selected separately on a multi-zone system
- Energy Star status
- ENERGY STAR certified[3]
- AHRI certification number
- 215792843Non-Ducted Indoor Units[2]
- Warranty
- Best case: 7 yr parts / 10 yr compressor (registration). 7-year limited parts / 10-year compressor warranty with registration
- Install path
- Professional install
- Retail price
- We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-29.
- Available retailers
- not published
- Manual links
- Friedrich 2026 Floating Air ductless brochure, AHRI public detail for FPHMR42A3D, ENERGY STAR exact AHRI rows for FPHMR42A3D, Friedrich R-454B multi-zone outdoor installation manual, Friedrich Floating Air official page, HVACDirect exact-offer audit for FPHMR42A3D, Friedrich Floating Air Pro multi-zone R-454B service manual, Friedrich Floating Air Pro X Multi-Zone submittal
- Specification sheet
- Friedrich Floating Air Pro X Multi-Zone submittal
- Last sourced date
- Jul 29, 2026
Electrical requirements
ShowHide
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 3/8 in[1]
- Line connection type
- not published
- Precharged length
- 125 ft[1]
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 262 ft[1]
- Max line set per indoor
- 82 ft[1]
- Max height between indoor units
- not published
- Indoor dimensions
- Indoor heads are selected separately on a multi-zone system
- Outdoor dimensions
- 38-3/8 x 32-7/8 x 14-1/8 in[1]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 172 lb[1]
- Drain size
- not published
Related systems and guides
- More Friedrich systems
- Della Vita Series Multi-Zone 42k 230V
- Fujitsu comparison model
- Floating Air Pro X 36k
- Floating Air Select 34.6k
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- The best multi-zone mini splits of 2026
- The best 4-zone mini splits of 2026
- How to size a multi-zone mini split
- Not every multi-zone condenser lets you mix head types
- How much does a multi-zone mini split cost?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- One room won't heat or cool on a multi-zone mini split
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split Wi-Fi not connecting
- Mini split remote not working
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Friedrich Floating Air Pro X 5-Zone 42,000 BTU R-454B 208/230V (FPHMR42A3D) myself, or do I need a pro?
- Friedrich Floating Air Pro X 5-Zone 42,000 BTU R-454B 208/230V (FPHMR42A3D) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Friedrich Floating Air Pro X 5-Zone 42,000 BTU R-454B 208/230V (FPHMR42A3D) keep heating in a cold winter?
- The manufacturer publishes 36,000 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 9.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Friedrich Floating Air Pro X 5-Zone 42,000 BTU R-454B 208/230V (FPHMR42A3D) need?
- Published electrical requirements: 230 V voltage, 36 A minimum circuit ampacity, and 40 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 262 ft, and the included line set comes pre-charged for 125 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
- What warranty does the Friedrich Floating Air Pro X 5-Zone 42,000 BTU R-454B 208/230V (FPHMR42A3D) carry?
- The manufacturer publishes these warranty tiers: Best case: 7 yr parts / 10 yr compressor (registration). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.
Data sources
ShowHide
- Friedrich Air Conditioning Co.: Friedrich Floating Air Pro X Multi-Zone submittalSourced - manufacturer technical document
Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Manufacturer wire notes and more
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public detail for FPHMR42A3DSourced - AHRI directory
Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more
- ENERGY STAR: ENERGY STAR product database exact AHRI rows for FPHMR42A3DSourced - secondary source
Covers performance_spec.energy_star_cold_climate, Energy Star status
Last updated
Jul 29, 2026