Pioneer Quantum Hyperformance 9k R-454B 208/230V Mini-Split
The Pioneer Quantum Hyperformance 9k is Pioneer's efficient cold-climate line on R-454B: SEER2 25, EER2 14.5, HSPF2 10.5, with certified heating of 9,000 BTU at 47F, 10,000 BTU at 17F and 9,100 BTU at 5F. Strong efficiency plus genuine cold-weather capacity.
Refrigerant generation
R-454B - current-generation refrigerant
Paid link
$1,208 / Checked Jul 24, 2026
Need this installed?
Get installation quotes
Image: Pioneer
- Last sourced
- Jul 24, 2026
SplitAtlas score
8.5 / 10
(25.0 SEER2) among <=9k systems
(10.5 HSPF2) among <=9k systems
(5F certified capacity: 100% of the 47F rating; -22 F heating floor) among <=9k systems
(26 dBA indoor min / 55 dBA outdoor) among <=9k systems
(6 verified features) across the catalogue
($1,208 median retail) among <=9k systems
(6 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- Top efficiency shortlists; SEER2 is 25.
Install difficulty
- Electrical: 230V; breaker/fuse 15 A.
- Line set: connection type not sourced; max 50 ft.
Alternatives
- Blueridge XS6 Max Efficiency 9,000 BTU R-454B 208/230V (BXS6A09WM0 / BXS6A09UC0)
8.9 score / 9k / SEER2 33.3 / -22 F heating floor / 230V
Exact destination at Alpine Home Air: $1,689.00, checked Jul 24, 2026
- Senville ELITE 9,000 BTU R-454B 208/230V (SENE-09EL-IHH / SENE-09EL-OH)
8.9 score / 9k / SEER2 33.3 / -22 F heating floor / 187-253V
Exact destination at Senville: $1,599.99, checked Jul 24, 2026
- ACiQ Extreme 9,000 BTU R-454B 208/230V (ACIQ-09W-HH-MD / ACIQ-09ZPL-HP230C)
8.9 score / 9k / SEER2 27.4 / -22 F heating floor / 230V
Exact destination at HVACDirect: $1,499.99, checked Jul 26, 2026
Availability and price context
- Last seen at Pioneer Mini Split on Jul 24, 2026: $1,208.00. Open the listing for today's price.
Source date
- Model data sourced
- Jul 24, 2026
- Page reviewed
- Jul 23, 2026
- Source-backed records
- 5
- Newest source retrieved
- Jul 24, 2026
Warranty tiers
No Base or Registered tier is established for scoring.
Model context
- Structured ratings
- Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.
Strengths
- SEER2 25 / EER2 14.5 - excellent efficiency for a 9k.
- Certified at 10,000 BTU at 17F, above its 47F rating - true cold-climate capability.
- Current R-454B refrigerant.
Weaknesses
- Thin dealer support; budget for a qualified installer.
- Priced above the Diamante lines.
Climate suitability
- Minimum heating ambient
- -22 F[2]
- Certified heating at 5F
- 9,100 BTU/h[4]
- Rated heating at 17F
- 10,000 BTU/h[4]
- Rated heating at 47F
- 9,000 BTU/h[4]
Specifications
ShowHide
- Manufacturer
- Pioneer
- Brand
- Pioneer
- Product line
- Quantum Hyperformance
- Model number
- WT009GLSI25HLH indoor / YN009GLSI25RPH outdoor
- Indoor unit model
- WT009GLSI25HLH
- Outdoor unit model
- YN009GLSI25RPH
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 9,000 BTU/h[4]
- Rated heating capacity
- 9,000 BTU/h[4]
- Voltage
- 230 V[1]
- MCA
- not published - manufacturer specifies 15 A breaker
- Maximum fuse or breaker size
- 15 A[1]
- Breaker needed
- 15 A[1]
- SEER2
- 25 SEER2[4]
- EER2
- 14.5 EER2[4]
- HSPF2 (Region 4)
- 10.5 HSPF2[4]
- HSPF2 (Region 5)
- not published
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 1.8 COP[4]
- Minimum outdoor heating temperature
- -22 F[2]
- Minimum outdoor cooling temperature
- 5 F[2]
- Maximum outdoor temperature
- 131 F[2]
- Indoor noise range
- 42/39/33/29/26 dB(A)[2]
- Outdoor noise rating
- 55 dBA[1]
- Indoor weight
- 20.7 lb[1]
- Outdoor weight
- 54 lb[1]
- Refrigerant
- R-454B[4]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- 50 ft[2]
- Max line set per indoor
- not published
- Maximum elevation difference
- 33 ft[2]
- Max height between indoor units
- not published
- Wi-Fi support
- supported[3]
- Energy Star status
- ENERGY STAR certified[5]
- AHRI certification number
- 217048754[4]
- Warranty
- Up to 10-year Pioneer warranty for registered eligible Quantum Hyperformance systems.
- Install path
- Professional install
- Retail price
- $1,208.00
- Available retailers
- Pioneer
- Manual links
- WYT009GLSI25RH AHRI certificate, WYT009GLSI25RH EnergyGuide, WYT25 installation manual, WYT25 service manual, WYT009GLSI25RH submittal sheet, WYT25 technical brochure
- Specification sheet
- WYT009GLSI25RH submittal sheet
- Last sourced date
- Jul 24, 2026
Retail purchase context
Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure
Paid link
$1,208 / Checked Jul 24, 2026
Electrical requirements
ShowHide
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 3/8 in[1]
- Line connection type
- not published
- Precharged length
- not published
- Included line-set length
- Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- 50 ft[2]
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- 32-1/4 x 7-5/8 x 12 in[1]
- Outdoor dimensions
- 31-7/8 x 12 x 21-5/8 in[1]
- Indoor weight
- 20.7 lb[1]
- Outdoor weight
- 54 lb[1]
- Drain size
- not published
Related systems and guides
- More Pioneer systems
- Pioneer Diamante Pro 9k R-454B 208/230V Mini-Split
- Pioneer Quantum Ultra 9k R-454B 115V Mini-Split
- Pioneer Diamante Pro 9k R-454B 115V Mini-Split
- Pioneer Quantum Ultra 9k R-454B 208/230V Mini-Split
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Pioneer mini split review: is Pioneer any good?
- The best 9,000 BTU mini splits of 2026
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- Pioneer mini split not cooling
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split leaking water
- Mini split short cycling
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) myself, or do I need a pro?
- Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) keep heating in a cold winter?
- The AHRI/ENERGY STAR certification lists 9,100 BTU/h of heating capacity at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) need?
- Published electrical requirements: 230 V voltage and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 50 ft. Measure the planned routing before ordering.
Data sources
ShowHide
- Pioneer Mini Split: Quantum Hyperformance WYT009GLSI25RH product pageSourced - manufacturer product page
Covers Breaker needed, Frequency, Maximum breaker size, Maximum fuse size, Phase, Voltage and more
- Pioneer / Parker Davis HVAC International, Inc.: WYT009GLSI25RH submittal sheetSourced - manufacturer technical document
Covers Maximum cooling current, Maximum heating current, Indoor noise range, Maximum elevation difference, Maximum line-set length, Minimum outdoor cooling temperature and more
- Pioneer Mini Split: Pioneer wall-mounted mini-split model comparison guideSourced - manufacturer product page
Covers Wi-Fi support, Legacy compressor warranty value, Legacy warranty value, Warranty notes
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public row for YN009GLSI25RPH / WT009GLSI25HLHSourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR: ENERGY STAR exact row check for AHRI 217048754Sourced - Energy Star listing
Covers Energy Star status
Last updated
Jul 23, 2026