SplitAtlas

Pioneer / Quantum Hyperformance

Pioneer Quantum Hyperformance 9k R-454B 208/230V Mini-Split

Certified capacity
9,000 BTU/h[4]
SEER2
25 SEER2[4]
Heating floor
-22 F[2]
Voltage
230 V[1]
Install path
Professional install

The Pioneer Quantum Hyperformance 9k is Pioneer's efficient cold-climate line on R-454B: SEER2 25, EER2 14.5, HSPF2 10.5, with heating that climbs from 9,000 BTU at 47F to 10,000 BTU at 17F and holds 9,100 BTU at 5F. Strong efficiency plus genuine cold-weather boost.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Paid link

$1,208 / Fresh price - checked Jul 24, 2026

Check price at Pioneer

Need this installed?

Get installation quotes
Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) mini-split heat pump indoor wall unit and outdoor condenser

Image: Pioneer

Data completeness: 100%
Last sourced
Jul 24, 2026

SplitAtlas score

8.5 / 10

Methodology
Cooling efficiencyAbove average

(25.0 SEER2) among <=9k systems

Heating efficiencyBelow average

(10.5 HSPF2) among <=9k systems

Cold-weather performanceTop quartile

(100% heat retained at 5F; -22 F heating floor) among <=9k systems

NoiseBottom quartile

(26 dBA indoor min / 55 dBA outdoor) among <=9k systems

Feature setTop quartile

(6 verified features) across the catalogue

Price-to-performanceBelow average

($1,208 median retail) among <=9k systems

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

Key ratings

Rated cooling

9,000BTU/h[4]

Rated heating

9,000BTU/h[4]

Buyer review snapshot

Best for / skip if

Best for

  • Top efficiency shortlists; SEER2 is 25.

Install difficulty

Professional install
  • Electrical: 230V; breaker/fuse 15 A.
  • Line set: connection type not sourced; max 50 ft.

Alternatives

Availability and price context

  • Verified current price: $1,208.00 at Pioneer; availability in_stock; checked Jul 24, 2026.

Source date

Model data sourced
Jul 24, 2026
Page reviewed
Jul 23, 2026
Source-backed records
5
Newest source retrieved
Jul 24, 2026

Warranty tiers

Warranty: Up to 10-year Pioneer warranty for registered eligible Quantum Hyperformance systems.

Review methodology

Model context

Structured ratings
Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.

Strengths

  • SEER2 25 / EER2 14.5 - excellent efficiency for a 9k.
  • Heating boosts to 10,000 BTU at 17F - true cold-climate capability.
  • Current R-454B refrigerant.

Weaknesses

  • Thin dealer support; budget for a qualified installer.
  • Priced above the Diamante lines.

Climate suitability

Minimum heating ambient
-22 F[2]
Rated heating at 5F
9,100 BTU/h[4]
Rated heating at 17F
10,000 BTU/h[4]
Rated heating at 47F
9,000 BTU/h[4]

Specifications

Show
Manufacturer
Pioneer
Brand
Pioneer
Product line
Quantum Hyperformance
Model number
WT009GLSI25HLH indoor / YN009GLSI25RPH outdoor
Indoor unit model
WT009GLSI25HLH
Outdoor unit model
YN009GLSI25RPH
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/h[4]
Rated heating capacity
9,000 BTU/h[4]
Voltage
230 V[1]
MCA
not published - manufacturer specifies 15 A breaker
Maximum fuse or breaker size
15 A[1]
Breaker needed
15 A[1]
SEER2
25 SEER2[4]
EER2
14.5 EER2[4]
HSPF2 (Region 4)
10.5 HSPF2[4]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
1.8 COP[4]
Minimum outdoor heating temperature
-22 F[2]
Minimum outdoor cooling temperature
5 F[2]
Maximum outdoor temperature
131 F[2]
Indoor noise range
42/39/33/29/26 dB(A)[2]
Outdoor noise rating
55 dBA[1]
Indoor weight
20.7 lb[1]
Outdoor weight
54 lb[1]
Refrigerant
R-454B[4]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
Maximum line-set length
50 ft[2]
Max line set per indoor
not published
Maximum elevation difference
33 ft[2]
Max height between indoor units
not published
Wi-Fi support
supported[3]
Energy Star status
ENERGY STAR certified[5]
AHRI certification number
217048754[4]
Warranty
Up to 10-year Pioneer warranty for registered eligible Quantum Hyperformance systems.
Install path
Professional install
Retail price
$1,208.00
Available retailers
Pioneer
Manual links
WYT009GLSI25RH AHRI certificate, WYT009GLSI25RH EnergyGuide, WYT25 installation manual, WYT25 service manual, WYT009GLSI25RH submittal sheet, WYT25 technical brochure
Specification sheet
WYT009GLSI25RH submittal sheet
Last sourced date
Jul 24, 2026

Retail purchase context

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at Pioneer

$1,208 / Fresh price - checked Jul 24, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
not published - manufacturer specifies 15 A breaker
Breaker needed
15 A[1]
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
3 A[2]
Maximum heating current
3.3 A[2]
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
not published
Included line-set length
Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
Maximum line-set length
50 ft[2]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
32-1/4 x 7-5/8 x 12 in[1]
Outdoor dimensions
31-7/8 x 12 x 21-5/8 in[1]
Indoor weight
20.7 lb[1]
Outdoor weight
54 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) myself, or do I need a pro?
Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) keep heating in a cold winter?
The manufacturer publishes 9,100 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) need?
Published electrical requirements: 230 V voltage, not published - manufacturer specifies 15 A breaker minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 50 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.

Data sources

Show
  1. Pioneer Mini Split: Quantum Hyperformance WYT009GLSI25RH product pageSourced - manufacturer product page

    Covers Breaker needed, Frequency, Maximum breaker size, Maximum fuse size, Phase, Voltage and more

  2. Pioneer / Parker Davis HVAC International, Inc.: WYT009GLSI25RH submittal sheetSourced - manufacturer technical document

    Covers Maximum cooling current, Maximum heating current, Indoor noise range, Maximum elevation difference, Maximum line-set length, Minimum outdoor cooling temperature and more

  3. Pioneer Mini Split: Pioneer wall-mounted mini-split model comparison guideSourced - manufacturer product page

    Covers Wi-Fi support, Legacy compressor warranty value, Legacy warranty value, Warranty notes

  4. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public row for YN009GLSI25RPH / WT009GLSI25HLHSourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  5. ENERGY STAR: ENERGY STAR exact row check for AHRI 217048754Sourced - Energy Star listing

    Covers Energy Star status

Last updated

Jul 23, 2026