The Pioneer Quantum Hyperformance 9k is Pioneer's efficient cold-climate line on R-454B: SEER2 25, EER2 14.5, HSPF2 10.5, with heating that climbs from 9,000 BTU at 47F to 10,000 BTU at 17F and holds 9,100 BTU at 5F. Strong efficiency plus genuine cold-weather boost.
Refrigerant generation
R-454B - current-generation refrigerant
Paid link
$1,208 / Fresh price - checked Jul 24, 2026
Need this installed?
Get installation quotes
Image: Pioneer
- Last sourced
- Jul 24, 2026
SplitAtlas score
8.5 / 10
(25.0 SEER2) among <=9k systems
(10.5 HSPF2) among <=9k systems
(100% heat retained at 5F; -22 F heating floor) among <=9k systems
(26 dBA indoor min / 55 dBA outdoor) among <=9k systems
(6 verified features) across the catalogue
($1,208 median retail) among <=9k systems
(6 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- Top efficiency shortlists; SEER2 is 25.
Install difficulty
- Electrical: 230V; breaker/fuse 15 A.
- Line set: connection type not sourced; max 50 ft.
Alternatives
- Blueridge XS6 Max Efficiency 9,000 BTU R-454B 208/230V (BXS6A09WM0 / BXS6A09UC0)
8.9 score / 9k / SEER2 33.3 / -22 F heating floor / 230V
Exact destination at Alpine Home Air: $1,689.00, checked Jul 24, 2026
- Senville ELITE 9,000 BTU R-454B 208/230V (SENE-09EL-IHH / SENE-09EL-OH)
8.8 score / 9k / SEER2 33.3 / -22 F heating floor / 187-253V
Exact destination at Senville: $1,599.99, checked Jul 24, 2026
- ACiQ Extreme 9,000 BTU R-454B 208/230V (ACIQ-09W-HH-MD / ACIQ-09ZPL-HP230C)
8.8 score / 9k / SEER2 27.4 / -22 F heating floor / 230V
Exact destination at HVACDirect: $1,499.99, checked Jul 26, 2026
Availability and price context
- Verified current price: $1,208.00 at Pioneer; availability in_stock; checked Jul 24, 2026.
Source date
- Model data sourced
- Jul 24, 2026
- Page reviewed
- Jul 23, 2026
- Source-backed records
- 5
- Newest source retrieved
- Jul 24, 2026
Warranty tiers
Warranty: Up to 10-year Pioneer warranty for registered eligible Quantum Hyperformance systems.
Model context
- Structured ratings
- Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.
Strengths
- SEER2 25 / EER2 14.5 - excellent efficiency for a 9k.
- Heating boosts to 10,000 BTU at 17F - true cold-climate capability.
- Current R-454B refrigerant.
Weaknesses
- Thin dealer support; budget for a qualified installer.
- Priced above the Diamante lines.
Climate suitability
- Minimum heating ambient
- -22 F[2]
- Rated heating at 5F
- 9,100 BTU/h[4]
- Rated heating at 17F
- 10,000 BTU/h[4]
- Rated heating at 47F
- 9,000 BTU/h[4]
Specifications
ShowHide
- Manufacturer
- Pioneer
- Brand
- Pioneer
- Product line
- Quantum Hyperformance
- Model number
- WT009GLSI25HLH indoor / YN009GLSI25RPH outdoor
- Indoor unit model
- WT009GLSI25HLH
- Outdoor unit model
- YN009GLSI25RPH
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 9,000 BTU/h[4]
- Rated heating capacity
- 9,000 BTU/h[4]
- Voltage
- 230 V[1]
- MCA
- not published - manufacturer specifies 15 A breaker
- Maximum fuse or breaker size
- 15 A[1]
- Breaker needed
- 15 A[1]
- SEER2
- 25 SEER2[4]
- EER2
- 14.5 EER2[4]
- HSPF2 (Region 4)
- 10.5 HSPF2[4]
- HSPF2 (Region 5)
- not published
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 1.8 COP[4]
- Minimum outdoor heating temperature
- -22 F[2]
- Minimum outdoor cooling temperature
- 5 F[2]
- Maximum outdoor temperature
- 131 F[2]
- Indoor noise range
- 42/39/33/29/26 dB(A)[2]
- Outdoor noise rating
- 55 dBA[1]
- Indoor weight
- 20.7 lb[1]
- Outdoor weight
- 54 lb[1]
- Refrigerant
- R-454B[4]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- 50 ft[2]
- Max line set per indoor
- not published
- Maximum elevation difference
- 33 ft[2]
- Max height between indoor units
- not published
- Wi-Fi support
- supported[3]
- Energy Star status
- ENERGY STAR certified[5]
- AHRI certification number
- 217048754[4]
- Warranty
- Up to 10-year Pioneer warranty for registered eligible Quantum Hyperformance systems.
- Install path
- Professional install
- Retail price
- $1,208.00
- Available retailers
- Pioneer
- Manual links
- WYT009GLSI25RH AHRI certificate, WYT009GLSI25RH EnergyGuide, WYT25 installation manual, WYT25 service manual, WYT009GLSI25RH submittal sheet, WYT25 technical brochure
- Specification sheet
- WYT009GLSI25RH submittal sheet
- Last sourced date
- Jul 24, 2026
Retail purchase context
Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure
Paid link
$1,208 / Fresh price - checked Jul 24, 2026
Electrical requirements
ShowHide
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 3/8 in[1]
- Line connection type
- not published
- Precharged length
- not published
- Included line-set length
- Pioneer full-set product page offers no-kit plus multiple 10/16/25/33/50 ft line-set variants; no single included line-set length applies to the certified system pair.
- Maximum line-set length
- 50 ft[2]
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- 32-1/4 x 7-5/8 x 12 in[1]
- Outdoor dimensions
- 31-7/8 x 12 x 21-5/8 in[1]
- Indoor weight
- 20.7 lb[1]
- Outdoor weight
- 54 lb[1]
- Drain size
- not published
Related systems and guides
- More Pioneer systems
- Pioneer 9k model
- Pioneer sibling model
- Diamante Pro 9k
- Pioneer sibling model
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Pioneer mini split review: is Pioneer any good?
- The best 9,000 BTU mini splits of 2026
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- Pioneer mini split not cooling
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split leaking water
- Mini split short cycling
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) myself, or do I need a pro?
- Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) keep heating in a cold winter?
- The manufacturer publishes 9,100 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Pioneer Quantum Hyperformance 9,000 BTU R-454B 208/230V (WT009GLSI25HLH / YN009GLSI25RPH) need?
- Published electrical requirements: 230 V voltage, not published - manufacturer specifies 15 A breaker minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 50 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
Data sources
ShowHide
- Pioneer Mini Split: Quantum Hyperformance WYT009GLSI25RH product pageSourced - manufacturer product page
Covers Breaker needed, Frequency, Maximum breaker size, Maximum fuse size, Phase, Voltage and more
- Pioneer / Parker Davis HVAC International, Inc.: WYT009GLSI25RH submittal sheetSourced - manufacturer technical document
Covers Maximum cooling current, Maximum heating current, Indoor noise range, Maximum elevation difference, Maximum line-set length, Minimum outdoor cooling temperature and more
- Pioneer Mini Split: Pioneer wall-mounted mini-split model comparison guideSourced - manufacturer product page
Covers Wi-Fi support, Legacy compressor warranty value, Legacy warranty value, Warranty notes
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public row for YN009GLSI25RPH / WT009GLSI25HLHSourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR: ENERGY STAR exact row check for AHRI 217048754Sourced - Energy Star listing
Covers Energy Star status
Last updated
Jul 23, 2026