Certified capacity
48,000 BTU/h[2]
SEER2
19 SEER2[2]
Heating floor
-13 F[1]
Voltage
230 V[1]
Install path
Professional install

The Pioneer Quantum Ultra 48k four-way cassette is the biggest Pioneer cassette in this batch, with 48,000 BTU cooling, 50,000 BTU heating at 47F, 40,500 BTU at 5F, and 19 SEER2.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Paid link

$4,993 / Fresh price - checked Aug 2, 2026

Check price at Pioneer

Need this installed?

Get installation quotes
Data completeness: 100%
Last sourced
Aug 2, 2026

SplitAtlas score

7.7 / 10

Methodology
Cooling efficiencyBelow average

(19.0 SEER2) among >36k systems

Heating efficiencyBelow average

(9.9 HSPF2) among >36k systems

Cold-weather performanceAbove average

(81% heat retained at 5F; -13 F heating floor) among >36k systems

NoiseBottom quartile

(38 dBA indoor min / 64 dBA outdoor) across the catalogue

Feature setAbove average

(6 verified features) across the catalogue

Price-to-performanceBelow average

($4,993 median retail) across the catalogue

Documentation & partsBelow average

(4 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

Key ratings

Rated cooling

48,000BTU/h[2]

Rated heating

50,000BTU/h[2]

Buyer review snapshot

Install difficulty

Professional install
  • Electrical: 230V; MCA 40 A; breaker/fuse 40 A.

Availability and price context

  • Verified current price: $4,993.00 at Pioneer; availability in_stock; checked Aug 2, 2026.

Source date

Model data sourced
Aug 2, 2026
Page reviewed
Aug 12, 2026
Source-backed records
3
Newest source retrieved
Aug 2, 2026

Warranty tiers

Warranty: up to 10-year Quantum Ultra warranty coverage

Review methodology

Model context

Structured ratings
Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.

Strengths

  • Highest cassette capacity captured for Pioneer.
  • ENERGY STAR exact row and cold-climate designation are present in the source set.
  • 40,500 BTU at 5F is strong absolute cold-weather output.
  • Complete official specs include 38 to 56 dB indoor sound and 40A breaker sizing.

Weaknesses

  • HSPF2 9.9 and EER2 9.5 are capacity-first, not efficiency-first.
  • Large indoor panel and 3/4 gas line require commercial-style planning.
  • More expensive than the 36k cassette and less efficient per BTU.

Climate suitability

Minimum heating ambient
-13 F[1]
Rated heating at 5F
40,500 BTU/h[2]
Rated heating at 17F
36,600 BTU/h[2]
Rated heating at 47F
50,000 BTU/h[2]

Specifications

Show
Manufacturer
Pioneer
Brand
Pioneer
Product line
Quantum Ultra
Model number
CB048GMSILDFHG indoor / YN048GMSI20RUG outdoor
Indoor unit model
CB048GMSILDFHG
Outdoor unit model
YN048GMSI20RUG
Number of zones
1
Max indoor units
not published
Rated cooling capacity
48,000 BTU/h[2]
Rated heating capacity
50,000 BTU/h[2]
Voltage
230 V[1]
MCA
40 A[1]
Maximum fuse or breaker size
40 A[1]
Breaker needed
40 A[1]
SEER2
19 SEER2[2]
EER2
9.5 EER2[2]
HSPF2 (Region 4)
9.9 HSPF2[2]
HSPF2 (Region 5)
7.7 HSPF2[1]
COP
not published
COP at 47F
not published
COP at 5F
2.11 COP[2]
Minimum outdoor heating temperature
-13 F[1]
Minimum outdoor cooling temperature
5 F[1]
Maximum outdoor temperature
131 F[1]
Indoor noise range
( Turbo/Hi/Med/Lo/Mute): 56 / 52 / 50 / 42 / 38 dB(A)[1]
Outdoor noise rating
64 dBA[1]
Indoor weight
64.5 lb[1]
Outdoor weight
208.8 lb[1]
Refrigerant
R-454B[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
3/8 in liquid / 3/4 in suction
Included line-set length
Pioneer full-set product page offers multiple no-kit and line-set variants; no single included line-set length applies to the certified system pair.
Maximum line-set length
Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.
Max line set per indoor
not published
Maximum elevation difference
Pioneer product pages in the cached collection did not publish a single maximum elevation for these full-set variants.
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
218010992[2]
Warranty
up to 10-year Quantum Ultra warranty coverage
Install path
Professional install
Retail price
$4,993.00
Available retailers
Pioneer
Manual links
AHRI Active row 218010992, Four-Way Ceiling Cassette installation requirements from Pioneer product technical table, Pioneer® Quantum Ultra™ 48,000 BTU 19 SEER2 230V 4-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump official product page, Pioneer® Quantum Ultra™ 48,000 BTU 19 SEER2 230V 4-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump official product-page technical table
Specification sheet
Pioneer® Quantum Ultra™ 48,000 BTU 19 SEER2 230V 4-Way Ceiling Cassette Ductless Mini-Split Air Conditioner Inverter Heat Pump official product-page technical table
Last sourced date
Aug 2, 2026

Retail purchase context

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at Pioneer

$4,993 / Fresh price - checked Aug 2, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
single-phase[1]
Frequency
60 Hz[1]
MCA
40 A[1]
Breaker needed
40 A[1]
Maximum breaker size
40 A[1]
Maximum fuse size
40 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
3/8 in[1]
Suction line
3/4 in[1]
Line connection type
not published
Precharged length
not published
Included line-set length
Pioneer full-set product page offers multiple no-kit and line-set variants; no single included line-set length applies to the certified system pair.
Maximum line-set length
Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
32"-5/8 x 32"-5/8 x 11"-3/8 Inches[1]
Outdoor dimensions
37"-1/2 x 16"-3/8 x 52"-1/2 Inches[1]
Indoor weight
64.5 lb[1]
Outdoor weight
208.8 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Pioneer Quantum Ultra Four-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CB048GMSILDFHG / YN048GMSI20RUG) myself, or do I need a pro?
Pioneer Quantum Ultra Four-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CB048GMSILDFHG / YN048GMSI20RUG) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Pioneer Quantum Ultra Four-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CB048GMSILDFHG / YN048GMSI20RUG) keep heating in a cold winter?
The manufacturer publishes 40,500 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 9.9 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Pioneer Quantum Ultra Four-Way Ceiling Cassette 48,000 BTU R-454B 208/230V (CB048GMSILDFHG / YN048GMSI20RUG) need?
Published electrical requirements: 230 V voltage, 40 A minimum circuit ampacity, and 40 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is Pioneer product pages in the cached collection did not publish a single maximum line-set length for these full-set variants.. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.

Data sources

Show
  1. Pioneer / Parker Davis HVAC International, Inc.: Pioneer® Quantum Ultra™ 48,000 BTU 17 SEER2 230V Slim-Duct Ceiling Concealed Mini-Split Air Conditioner Inverter Heat Pump Full SetSourced - manufacturer product page

    Covers Breaker needed, Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active form-factor row 218010992Sourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  3. ENERGY STAR: ENERGY STAR exact row check for AHRI 218010994Sourced - Energy Star listing

    Covers Energy Star status

Last updated

Aug 12, 2026