SplitAtlas

Senville / AURA

Senville AURA 9k 230V (SENA-09HF)

Model data is drawn from manufacturer, retailer, and certification sources. Missing specifications remain marked as not published.

1 zoneProfessional installProfessional installCurrent
Senville AURA 9k mini-split heat pump indoor wall unit and outdoor condenser

Image: Senville

Data completeness: 85%
Last verified
Jul 18, 2026

SplitAtlas score

not yet rated - we score against comparable systems, and this class needs more verified models first.

Methodology
  • we score against comparable systems, and this class needs more verified models first (1/4 rated systems)

1. Summary

The smallest AURA carries the same cold-climate DNA as its siblings - published rated heating to -22F and the best certified efficiency numbers in our 9k class - at a price that routinely undercuts DIY-marketed alternatives. The trade: it requires professional installation and a 230V dedicated circuit.

Rated cooling

9,000BTU/hVerified - AHRI certificate

Rated heating

12,000BTU/hVerified - AHRI certificate

2. Best-fit use cases

Bedrooms and offices in cold climates where the unit carries real winter heating duty, and efficiency-focused buyers with an installer already lined up.

3. Key specifications

Manufacturer
Senville
Brand
Senville
Product line
AURA
Model number
SENA-09HF-IGG indoor / SENA-09HF-OG outdoor
Indoor unit model
SENA-09HF-IGG
Outdoor unit model
SENA-09HF-OG
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/hVerified - AHRI certificate
Rated heating capacity
12,000 BTU/hVerified - AHRI certificate
Voltage
208/230VVerified - manufacturer product page
MCA
10 AVerified - manufacturer product page
Maximum fuse or breaker size
15 AVerified - manufacturer product page
Breaker needed
not published
SEER2
27.4 SEER2Verified - AHRI certificate
EER2
15.4 EER2Verified - AHRI certificate
HSPF2 (Region 4)
12.5 HSPF2Verified - AHRI certificate
HSPF2 (Region 5)
9.8 HSPF2Verified - manufacturer product page
COP
not published
COP at 47F
not published
COP at 5F
not published
Minimum outdoor heating temperature
-22 FVerified - manufacturer product page
Minimum outdoor cooling temperature
not published
Maximum outdoor temperature
not published
Indoor noise range
45/37/31/23 dB(A)Verified - manufacturer product page
Outdoor noise rating
56 dBAVerified - manufacturer product page
Indoor weight
22.05 lbVerified - manufacturer product page
Outdoor weight
66.14 lbVerified - manufacturer product page
Refrigerant
R454BVerified - manufacturer product page
Refrigerant charge
37.15 ozVerified - manufacturer product page
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
not published
Maximum line-set length
not published
Max line set per indoor
not published
Maximum elevation difference
not published
Max height between indoor units
not published
Wi-Fi support
supportedVerified - manufacturer product page
Energy Star status
certifiedVerified - manufacturer product page
AHRI certification number
215735295Verified - AHRI certificate
Warranty
5 years parts / 10 years compressor. 10-year compressor and 5-year parts warranty; professional installation required.
DIY installation status
Professional install
Retail price
$1,299.99
Installation type
Professional install
Available retailers
Senville
Manual links
Senville AURA R454B Installation Manual (IGG/OG), Senville AURA R454B Owner Manual (IGG/OG), Senville AURA R454B Service Manual (IAA/OG)
Specification sheet
not published
Last verified date
Jul 18, 2026

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at Senville

$1,300 / Fresh price - checked Jul 18, 2026

Get installation quotes

The Senville AURA 9k 230V (SENA-09HF) is a professionally installed system - its warranty requires installation by a licensed contractor. Tell us about your project and we'll match you with local installers for quotes.

We are paid when you request a quote.

Parts & filters

Fits Senville AURA 9k 230V (SENA-09HF). Part numbers and fit notes identify compatibility only; no manufacturer endorsement is implied.

filter-optional

High density filter (optional accessory)

Fits
Senville AURA 9k 230V (SENA-09HF)
Fit note
Fits SENA-09HF. Senville lists a high-density filtration element as an optional accessory for the AURA line, on top of the standard washable screen. Order through Senville support with your model number - no part number is published in the catalog.
Source
Senville Product Catalog, Features AURA - Optional Features, page p. 3 (HIGH DENSITY FILTER)

air-cleaning-accessory

Plasma ionizer (optional accessory)

Fits
Senville AURA 9k 230V (SENA-09HF)
Fit note
Fits SENA-09HF. An optional air-cleaning module for the AURA indoor unit, listed in Senville's catalog; availability is confirmed at order time through Senville support.
Source
Senville Product Catalog, Features AURA - Optional Features, page p. 3 (PLASMA IONIZER)

wired-control

Wired wall controller (optional accessory)

Fits
Senville AURA 9k 230V (SENA-09HF)
Fit note
Fits SENA-09HF. A wired wall thermostat-style controller is available as an AURA option - useful where the handheld remote is impractical (rentals, commercial spaces).
Source
Senville Product Catalog, Features AURA - Optional Features, page p. 3 (WIRED CONTROL)

remote-control

Remote control (Follow Me)

Fits
Senville AURA 9k 230V (SENA-09HF)
Fit note
Fits SENA-09HF. The standard AURA remote includes the Follow Me ambient sensor; replacements are ordered through Senville support with your model number.
Source
Senville Product Catalog, Features AURA - Standard Features, page p. 3 (FOLLOW ME)
Replacement Parts & Filters

4. Strengths

  • Best certified efficiency in our published 9k class (SEER2 27.4 / HSPF2 12.5).
  • Published -22F heating floor - full cold-climate capability in a bedroom-sized unit.
  • 23 dB(A) low fan level plus Wi-Fi control - strong bedroom manners.
  • Aggressive direct pricing.

5. Weaknesses

  • Professional install required; warranty expects qualified installation.
  • 230V dedicated circuit for a small room is a real cost adder where the panel is far away.
  • Senville marketing figures have exceeded the unit's own AHRI certificate in our checks - we publish the certified numbers.

6. Climate suitability

Minimum heating ambient
-22 FVerified - manufacturer product page
Rated heating at 5F
not published
Rated heating at 17F
not published
Rated heating at 47F
not published

7. Electrical requirements

Voltage
not published
Voltage range
208/230VVerified - manufacturer product page
Phase
1Verified - manufacturer product page
Frequency
60 HzVerified - manufacturer product page
MCA
10 AVerified - manufacturer product page
Breaker needed
not published
Maximum breaker size
not published
Maximum fuse size
15 AVerified - manufacturer product page
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

8. Installation considerations

Liquid line
1/4 inVerified - manufacturer product page
Suction line
3/8 inVerified - manufacturer product page
Precharged length
not published
Included line-set length
not published
Maximum line-set length
not published
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
33.40 x 9.18 x 11.76 inVerified - manufacturer product page
Outdoor dimensions
28.74 x 11.02 x 19.49 inVerified - manufacturer product page
Indoor weight
22.05 lbVerified - manufacturer product page
Outdoor weight
66.14 lbVerified - manufacturer product page
Drain size
not published

9. Operating-cost estimate

not published

10. Comparable models

Frequently asked questions

Can I install the Senville AURA 9k 230V (SENA-09HF) myself, or do I need a pro?
Senville AURA 9k 230V (SENA-09HF) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Senville AURA 9k 230V (SENA-09HF) keep heating in a cold winter?
Rated heating operation extends down to -22 F. Certified heating efficiency is 12.5 HSPF2. Match that published heating floor against your climate's design temperature - below the low-ambient rating, output can fall off or the system can pause to protect itself.
What electrical circuit does the Senville AURA 9k 230V (SENA-09HF) need?
Published electrical requirements: 208/230V voltage, 10 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
What warranty does the Senville AURA 9k 230V (SENA-09HF) carry?
The manufacturer publishes 5 years parts coverage and 10 years compressor coverage. Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

11. Data sources

12. Last updated date

Jul 18, 2026