ACiQ / ACiQ Extreme

ACiQ Extreme 12k R-454B 208/230V Mini-Split

Certified capacity
12,000 BTU/h[2]
SEER2
25.4 SEER2[2]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The one-ton-class Extreme unit brings the flagship cold-climate treatment to 230V with 25.4 SEER2, 13.4 EER2, and 10.5 HSPF2 on R-454B, ENERGY STAR certified and cold-climate designated. Like its 9k sibling, it holds 12,000 BTU at 47F flat to 12,000 BTU at 17F, then eases only to 11,500 BTU at 5F. That near-flat curve is the reason to buy this tier.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Paid link

$1,650 / Checked Jul 26, 2026

$1,650 at HVACDirect

Need this installed?

Get installation quotes
ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C)

Image: ACiQ

Data completeness: 93%
Last sourced
Jul 26, 2026

SplitAtlas score

8.9 / 10

Methodology
Cooling efficiencyTop quartile

(25.4 SEER2) among 12k systems

Heating efficiencyAbove average

(10.5 HSPF2) among 12k systems

Cold-weather performanceTop quartile

(5F certified capacity: 95.8% of the 47F rating; -22 F heating floor) among 12k systems

NoiseAbove average

(19.5 dBA indoor min / 56 dBA outdoor) among 12k systems

WarrantyTop 10%

(7 yr parts / 12 yr compressor) across the catalogue

Feature setAbove average

(5 verified features) across the catalogue

Price-to-performanceBelow average

($1,650 median retail) among 12k systems

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

Key ratings

Rated cooling

12,000BTU/h[2]

Rated heating

12,000BTU/h[2]

Buyer review snapshot

Best for / skip if

Best for

  • Top efficiency shortlists; SEER2 is 25.4.

Install difficulty

Professional install
  • Electrical: 230V; MCA 15 A; breaker/fuse 15 A.
  • Line set: connection type not sourced; precharged 25 ft.

Alternatives

Availability and price context

  • Last seen at HVACDirect on Jul 26, 2026: $1,649.99. Open the listing for today's price.

Source date

Model data sourced
Jul 26, 2026
Page reviewed
Jul 26, 2026
Source-backed records
3
Newest source retrieved
Jul 26, 2026

Warranty tiers

Registered
7 yr parts / 12 yr compressor - published per-line terms with online registration

The score uses Registered. Additional published terms are shown for reference and not counted in the score.

Review methodology

Strengths

  • Maintains full 12,000 BTU from 47F to 17F and still 11,500 BTU at 5F - exceptional cold-climate carry.
  • ENERGY STAR certified and cold-climate designated, with a strong 25.4 SEER2 for efficient cooling too.

Weaknesses

  • HSPF2 of 10.5 is good but the lowest of the Extreme 230V units, so it's less of a seasonal-efficiency leader than the 9k.
  • Flagship pricing, and the value brand's service network is thinner than premium rivals.

Climate suitability

Minimum heating ambient
-22 F[1]
Certified heating at 5F
11,500 BTU/h[2]
Rated heating at 17F
12,000 BTU/h[2]
Rated heating at 47F
12,000 BTU/h[2]

Specifications

Show
Manufacturer
ACiQ
Brand
ACiQ
Product line
ACiQ Extreme
Model number
ACIQ-12W-HH-MD indoor / ACIQ-12ZPL-HP230C outdoor
Indoor unit model
ACIQ-12W-HH-MD
Outdoor unit model
ACIQ-12ZPL-HP230C
Number of zones
1
Max indoor units
not published
Rated cooling capacity
12,000 BTU/h[2]
Rated heating capacity
12,000 BTU/h[2]
Voltage
230 V[1]
MCA
15 A[1]
Maximum fuse or breaker size
15 A[1]
Breaker needed
not published
SEER2
25.4 SEER2[2]
EER2
13.4 EER2[2]
HSPF2 (Region 4)
10.5 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
1.8 COP[2]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
-22 F[1]
Maximum outdoor temperature
122 F[1]
Indoor noise range
19.5 / 47 dB(A)[1]
Outdoor noise rating
56 dBA[1]
Indoor weight
29.32 lb[1]
Outdoor weight
78.7 lb[1]
Refrigerant
R-454B[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Line set length is selected as an accessory on this HVACDirect system page.
Maximum line-set length
not published
Max line set per indoor
not published
Maximum elevation difference
not published
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
216032335[2]
Warranty
Registered: 7 yr parts / 12 yr compressor (published per-line terms with online registration). Score uses Registered.. 12-year compressor / 7-year parts with online registration
Install path
Professional install
Retail price
$1,649.99
Available retailers
HVACDirect
Manual links
AHRI public directory record 216032335, ENERGY STAR exact check 216032335, 12,000 BTU ACiQ Extreme 25.4 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 230V HVACDirect installation resources listing, 12,000 BTU ACiQ Extreme 25.4 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 230V, 12,000 BTU ACiQ Extreme 25.4 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 230V HVACDirect product specification grid
Specification sheet
12,000 BTU ACiQ Extreme 25.4 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 230V HVACDirect product specification grid
Last sourced date
Jul 26, 2026

Retail purchase context

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

$1,650 at HVACDirect

$1,650 / Checked Jul 26, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
15 A[1]
Breaker needed
not published
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
25 ft[1]
Included line-set length
Line set length is selected as an accessory on this HVACDirect system page.
Maximum line-set length
not published
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
33.40 x 11.76 x 9.18 in[1]
Outdoor dimensions
31.69 x 21.81 x 12.99 in[1]
Indoor weight
29.32 lb[1]
Outdoor weight
78.7 lb[1]
Drain size
not published

Comparable models

Frequently asked questions

Can I install the ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C) myself, or do I need a pro?
ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C) keep heating in a cold winter?
The AHRI/ENERGY STAR certification lists 11,500 BTU/h of heating capacity at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.5 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C) need?
Published electrical requirements: 230 V voltage, 15 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
What warranty does the ACiQ Extreme 12,000 BTU R-454B 208/230V (ACIQ-12W-HH-MD / ACIQ-12ZPL-HP230C) carry?
The manufacturer publishes these warranty tiers: Registered: 7 yr parts / 12 yr compressor (published per-line terms with online registration). Score uses Registered.. Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. HVACDirect / ACiQ: 12,000 BTU ACiQ Extreme 25.4 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 230VSourced - manufacturer product page

    Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Voltage and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public detail for ACIQ-12ZPL-HP230C / ACIQ-12W-HH-MDSourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more

  3. ENERGY STAR: ENERGY STAR exact row check for AHRI 216032335Sourced - Energy Star listing

    Covers Energy Star status

Last updated

Jul 26, 2026