SplitAtlas

ACiQ / ACiQ Standard

ACiQ Standard 9k R-454B 115V Mini-Split

Certified capacity
9,000 BTU/h[2]
SEER2
24.5 SEER2[2]
Heating floor
-13 F[1]
Voltage
115 V[1]
Install path
Professional install

The Standard tier is where ACiQ's R-454B efficiency really climbs, and this 9,000 BTU, 115V unit is a standout: 24.5 SEER2, 15 EER2, and 10.7 HSPF2. It is both ENERGY STAR certified and AHRI cold-climate designated. Heating holds well - 10,000 BTU at 47F, 9,400 BTU at 17F, and 7,300 BTU at 5F - making it a genuinely high-performing small zone on ordinary 115V power.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Paid link

$960 / Fresh price - checked Jul 26, 2026

Check price at HVACDirect

Need this installed?

Get installation quotes
ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) mini-split heat pump indoor wall unit and outdoor condenser

Image: HVACDirect

Data completeness: 93%
Last sourced
Jul 26, 2026

SplitAtlas score

8.5 / 10

Methodology
Cooling efficiencyAbove average

(24.5 SEER2) among <=9k systems

Heating efficiencyAbove average

(10.7 HSPF2) among <=9k systems

Cold-weather performanceBelow average

(73% heat retained at 5F; -13 F heating floor) among <=9k systems

NoiseAbove average

(17.5 dBA indoor min / 53 dBA outdoor) among <=9k systems

WarrantyTop quartile

(7 yr parts / 12 yr compressor) across the catalogue

Feature setAbove average

(5 verified features) across the catalogue

Price-to-performanceAbove average

($960 median retail) among <=9k systems

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

Key ratings

Rated cooling

9,000BTU/h[2]

Rated heating

10,000BTU/h[2]

Buyer review snapshot

Install difficulty

Professional install
  • Electrical: 115V; MCA 18 A; breaker/fuse 20 A.
  • Line set: connection type not sourced; precharged 25 ft.

Alternatives

Availability and price context

  • Verified current price: $959.99 at HVACDirect; availability in_stock; checked Jul 26, 2026.

Source date

Model data sourced
Jul 26, 2026
Page reviewed
Jul 26, 2026
Source-backed records
3
Newest source retrieved
Jul 26, 2026

Warranty tiers

Warranty: 7 years parts and 12 years compressor as standard.

Review methodology

Strengths

  • Excellent efficiency across the board, with a 15 EER2 that's exceptional for a 115V 9k unit.
  • ENERGY STAR certified and cold-climate designated, keeping 9,400 BTU at 17F for dependable winter heat.
  • Buyable direct from HVACDirect, so a top-tier small zone stays easy to price and order.

Weaknesses

  • Low-temp output does step down to 7,300 BTU at 5F, softer than the flagship Extreme line in the deepest cold.
  • Value-brand backing means a thinner service network than premium cold-climate competitors.

Climate suitability

Minimum heating ambient
-13 F[1]
Rated heating at 5F
7,300 BTU/h[2]
Rated heating at 17F
9,400 BTU/h[2]
Rated heating at 47F
10,000 BTU/h[2]

Specifications

Show
Manufacturer
ACiQ
Brand
ACiQ
Product line
ACiQ Standard
Model number
ACIQ-09WS-HP115C indoor / ACIQ-09ZS-HP115C outdoor
Indoor unit model
ACIQ-09WS-HP115C
Outdoor unit model
ACIQ-09ZS-HP115C
Number of zones
1
Max indoor units
not published
Rated cooling capacity
9,000 BTU/h[2]
Rated heating capacity
10,000 BTU/h[2]
Voltage
115 V[1]
MCA
18 A[1]
Maximum fuse or breaker size
20 A[1]
Breaker needed
not published
SEER2
24.5 SEER2[2]
EER2
15 EER2[2]
HSPF2 (Region 4)
10.7 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
2.2 COP[2]
Minimum outdoor heating temperature
-13 F[1]
Minimum outdoor cooling temperature
-13 F[1]
Maximum outdoor temperature
122 F[1]
Indoor noise range
17.5 / 44 dB(A)[1]
Outdoor noise rating
53 dBA[1]
Indoor weight
26.01 lb[1]
Outdoor weight
70.11 lb[1]
Refrigerant
R-454B[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
Line set length is selected as an accessory on this HVACDirect system page.
Maximum line-set length
not published
Max line set per indoor
not published
Maximum elevation difference
not published
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
216980865[2]
Warranty
Standard: 7 yr parts / 12 yr compressor (published per-line terms with online registration). 12-year compressor / 7-year parts with online registration
Install path
Professional install
Retail price
$959.99
Available retailers
HVACDirect
Manual links
AHRI public directory record 216980865, ENERGY STAR exact check 216980865, 9,000 BTU ACiQ Standard 24.5 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 115V HVACDirect installation resources listing, 9,000 BTU ACiQ Standard 24.5 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 115V, HVACDirect exact affiliate offer aciq-standard-9k-r454b-115v, 9,000 BTU ACiQ Standard 24.5 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 115V HVACDirect product specification grid
Specification sheet
9,000 BTU ACiQ Standard 24.5 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 115V HVACDirect product specification grid
Last sourced date
Jul 26, 2026

Retail purchase context

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at HVACDirect

$960 / Fresh price - checked Jul 26, 2026

Electrical requirements

Show
Voltage
115 V[1]
Voltage range
115V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
18 A[1]
Breaker needed
not published
Maximum breaker size
20 A[1]
Maximum fuse size
20 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
not published
Precharged length
25 ft[1]
Included line-set length
Line set length is selected as an accessory on this HVACDirect system page.
Maximum line-set length
not published
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
31.57 x 11.61 x 7.87 in[1]
Outdoor dimensions
30.12 x 21.85 x 11.93 in[1]
Indoor weight
26.01 lb[1]
Outdoor weight
70.11 lb[1]
Drain size
not published

Frequently asked questions

Can I install the ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) myself, or do I need a pro?
ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) keep heating in a cold winter?
The manufacturer publishes 7,300 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10.7 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) need?
Published electrical requirements: 115 V voltage, 18 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
What warranty does the ACiQ Standard 9,000 BTU R-454B 115V (ACIQ-09WS-HP115C / ACIQ-09ZS-HP115C) carry?
The manufacturer publishes these warranty tiers: Standard: 7 yr parts / 12 yr compressor (published per-line terms with online registration). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. HVACDirect / ACiQ: 9,000 BTU ACiQ Standard 24.5 SEER2 Single Zone Wall Mount Mini Split Heat Pump System - R454B | 115VSourced - manufacturer product page

    Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Voltage and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Appendix M1 public detail for ACIQ-09ZS-HP115C / ACIQ-09WS-HP115CSourced - AHRI directory

    Covers AHRI certification number, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity, HSPF2 (Region 4) and more

  3. ENERGY STAR: ENERGY STAR exact row check for AHRI 216980865Sourced - Energy Star listing

    Covers Energy Star status

Last updated

Jul 26, 2026