Cooper & Hunter / Ceiling Cassette
Cooper Hunter Ceiling Cassette 12k Regular R-454B 208/230V Mini-Split
The standard-outdoor 12,000 BTU cassette certifies at 21.1 SEER2 and 10.4 HSPF2, rated to -13F. It is the budget end of the 12k cassette choice, and it gives up more to the hyper version than the 9k pair does - a point of SEER2, over a point of HSPF2, and nine degrees.
If the climate is mild, that is still a capable unit and the savings are real. If you are anywhere that sees single digits regularly, the hyper version is the better buy and the gap is wide enough to justify it.
Refrigerant generation
R-454B - current-generation refrigerant
Need this installed?
Get installation quotes- Last sourced
- Aug 2, 2026
SplitAtlas score
8.1 / 10
(21.1 SEER2) among 12k systems
(10.4 HSPF2) among 12k systems
(70% heat retained at 5F; -13 F heating floor) among 12k systems
(5 yr parts / 7 yr compressor) across the catalogue
(6 verified features) across the catalogue
(6 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Buyer review snapshot
Install difficulty
- Electrical: 230V; MCA 12 A; breaker/fuse 15 A.
- Line set: Flared line connections; precharged 25 ft; max 82 ft.
Alternatives
- Daikin ATMOSPHERA 12,000 BTU R-32 208/230V (FTXM12WVJU9 / RXM12WVJU9)
9.0 score / 12k / SEER2 25.2 / -13 F heating floor / 208/230V
Exact destination at HVACDirect: $2,848.00, checked Jul 23, 2026
- Blueridge XS6 Max Efficiency 12,000 BTU R-454B 208/230V (BXS6A12WM0 / BXS6A12UC0)
8.9 score / 12k / SEER2 29.4 / -22 F heating floor / 230V
Exact destination at Alpine Home Air: $1,979.00, checked Jul 24, 2026
- Senville ELITE 12,000 BTU R-454B 208/230V (SENE-12EL-IHH / SENE-12EL-OH)
8.9 score / 12k / SEER2 29.4 / -22 F heating floor / 187-253V
Exact destination at Senville: $1,699.99, checked Jul 24, 2026
Availability and price context
We could not verify a current retail price for this model. We do not currently have a verified in-stock offer from a retailer we work with when we last checked on 2026-08-02.
Source date
- Model data sourced
- Aug 2, 2026
- Page reviewed
- Aug 2, 2026
- Source-backed records
- 3
- Newest source retrieved
- Aug 2, 2026
Warranty tiers
Warranty: 5 years parts and 7 years compressor as standard.
Model context
- Structured ratings
- Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -13 F.
Strengths
- Full 12,000 BTU of heating and cooling at the lowest price point in the 12k cassette range.
- 10.4 HSPF2 remains a respectable heating figure.
Weaknesses
- Loses to the hyper version on all three figures, not just cold capability.
- -13F rating; a cold-climate home will want backup heat.
- Ceiling-recessed install is invasive and professional-only.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Rated heating at 5F
- 8,400 BTU/h[2]
- Rated heating at 17F
- 8,500 BTU/h[2]
- Rated heating at 47F
- 12,000 BTU/h[2]
Specifications
ShowHide
- Manufacturer
- Cooper & Hunter
- Brand
- Cooper & Hunter
- Product line
- Ceiling Cassette
- Model number
- CH-RH12MCT indoor / CH-RES12-230VO outdoor
- Indoor unit model
- CH-RH12MCT
- Outdoor unit model
- CH-RES12-230VO
- Number of zones
- 1
- Max indoor units
- not published
- Rated cooling capacity
- 12,000 BTU/h[2]
- Rated heating capacity
- 12,000 BTU/h[2]
- Voltage
- 230 V[1]
- MCA
- 12 A[1]
- Maximum fuse or breaker size
- 15 A[1]
- Breaker needed
- not published
- SEER2
- 21.1 SEER2[2]
- EER2
- 12.5 EER2[2]
- HSPF2 (Region 4)
- 10.4 HSPF2[2]
- HSPF2 (Region 5)
- not published
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 2.4 COP[2]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- -13 F[1]
- Maximum outdoor temperature
- 122 F[1]
- Indoor noise range
- not published
- Outdoor noise rating
- 52.5 dBA[1]
- Indoor weight
- not published
- Outdoor weight
- 62.17 lb[1]
- Refrigerant
- R-454B[2]
- Refrigerant charge
- not published
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
- Maximum line-set length
- 82 ft[1]
- Max line set per indoor
- not published
- Maximum elevation difference
- 49.2 ft[1]
- Max height between indoor units
- not published
- Wi-Fi support
- supported[1]
- Energy Star status
- ENERGY STAR certified[2]
- AHRI certification number
- 215864207[2]
- Warranty
- Standard: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). 7-year compressor and 5-year parts limited warranty with licensed-technician installation and registration terms.
- Install path
- Professional install
- Retail price
- We do not currently have a verified in-stock offer from a retailer we work with when we last checked on 2026-08-02.
- Available retailers
- not published
- Manual links
- AHRI Active public directory row 215864207, Installation manual R454B Ceiling Cassette, Cooper & Hunter Multi R installation manual, Cooper & Hunter Ceiling Cassette official product pages for CH-RH12MCT, Owner's manual R454B Ceiling Cassette, Cooper & Hunter support-material submittal for CH-RES12-230VO + CH-RH12MCT
- Specification sheet
- Cooper & Hunter support-material submittal for CH-RES12-230VO + CH-RH12MCT
- Last sourced date
- Aug 2, 2026
Electrical requirements
ShowHide
- Voltage
- 230 V[1]
- Voltage range
- 208/230V[1]
- Phase
- 1[1]
- Frequency
- 60 Hz[1]
- MCA
- 12 A[1]
- Breaker needed
- not published
- Maximum breaker size
- 15 A[1]
- Maximum fuse size
- 15 A[1]
- Maximum cooling current
- not published
- Maximum heating current
- not published
- Manufacturer wire notes
- Field wiring per C&H support-material submittal and local electrical code.[1]
Installation considerations
ShowHide
- Liquid line
- 1/4 in[1]
- Suction line
- 3/8 in[1]
- Line connection type
- Flared line connections[1]
- Precharged length
- 25 ft[1]
- Included line-set length
- C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
- Maximum line-set length
- 82 ft[1]
- Max line set per indoor
- not published
- Max height between indoor units
- not published
- Indoor dimensions
- not published
- Outdoor dimensions
- 30.12 x 11.93 x 21.85 in[1]
- Indoor weight
- not published
- Outdoor weight
- 62.17 lb[1]
- Drain size
- not published
Related systems and guides
- More Cooper & Hunter systems
- Carrier comparison model
Previous generation
- Cooper & Hunter 12k model
- Cooper & Hunter 11.5k model
- Carrier Performance 26 12k 230V
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Cooper & Hunter mini split review: is Cooper & Hunter any good?
- The best 12,000 BTU mini splits of 2026
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- The mini split defrost cycle, explained
- The best DIY mini splits of 2026
- What "DIY mini split" actually means
- How to install a mini split (DIY overview)
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split remote not working
- Mini split weak airflow
- Mini split lights blinking
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO) myself, or do I need a pro?
- Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO) keep heating in a cold winter?
- The manufacturer publishes 8,400 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10.4 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO) need?
- Published electrical requirements: 230 V voltage, 12 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 82 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
- What warranty does the Cooper & Hunter 4-Way Ceiling Cassette 12,000 BTU R-454B 208/230V (CH-RH12MCT / CH-RES12-230VO) carry?
- The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.
Data sources
ShowHide
- Cooper & Hunter: Cooper & Hunter support-material submittal for CH-RES12-230VO + CH-RH12MCTSourced - manufacturer technical document
Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more
- Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active Cooper & Hunter form-factor row 215864231Sourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Energy Star status and more
- Cooper & Hunter: Cooper & Hunter Multi R installation manual limited warranty sectionSourced - manufacturer technical document
Covers Legacy compressor warranty value, Legacy warranty value, Standard compressor warranty, Standard warranty conditions, Standard parts warranty, Warranty notes
Last updated
Aug 2, 2026