Certified capacity
36,000 BTU/h[3]
SEER2
23 SEER2[3]
Heating floor
-22 F[2]
Voltage
230 V[2]
Install path
Professional install

The Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36k (CH-RHP36M-230VO) is the cold-climate flagship, running five heads on one 208/230V outdoor unit while keeping heating strong in deep cold. It posts a certified nominal SEER2 of 23, EER2 13, and HSPF2 10.7 - the highest HSPF2 in this group - and its heating rises from 36000 BTU at 47F to 38000 at 17F before returning to 36000 at 5F, output at or above its 47F rating well into winter.

It uses current low-GWP R-454B refrigerant, is ENERGY STAR certified, and is AHRI cold-climate designated. Cooper & Hunter is a value-focused ductless brand that delivers high-efficiency inverter multi-zone below the premium names; professional installation required and units are dealer-quoted.

5 zonesProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Need this installed?

Get installation quotes
Data completeness: 95%
Last sourced
Jul 28, 2026

SplitAtlas score

9.1 / 10

Methodology
Cooling efficiencyTop quartile

(23.0 SEER2) among 36k systems

Heating efficiencyTop 10%

(10.7 HSPF2) among 36k systems

Cold-weather performanceTop quartile

(100% heat retained at 5F; -22 F heating floor) among 36k systems

WarrantyBelow average

(5 yr parts / 7 yr compressor) across the catalogue

Feature setTop quartile

(6 verified features) across the catalogue

Documentation & partsBottom quartile

(8 manuals; parts channel) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

36,000BTU/hNon-Ducted Indoor Units[3]

Rated heating

36,000BTU/hNon-Ducted Indoor Units[3]

Buyer review snapshot

Best for / skip if

Best for

  • 5-zone projects in the 36k outdoor capacity class.
  • High-efficiency shortlists; SEER2 is 23.

Install difficulty

Professional flared-line install
  • Electrical: 230V; MCA 37 A; breaker/fuse 40 A.
  • Line set: Flared line connections; precharged 125 ft; max 262.4 ft.
  • 5-zone condenser; indoor-head matching and branch layout are part of the job.

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.

Source date

Model data sourced
Jul 28, 2026
Page reviewed
Jul 28, 2026
Source-backed records
4
Newest source retrieved
Jul 28, 2026

Warranty tiers

Warranty: 5 years parts and 7 years compressor as standard.

Review methodology

Model context

Install path
This is professional-install equipment; no verified current retail offer is attached.
Structured ratings
Certification: ENERGY STAR certified, ENERGY STAR cold-climate certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.

Strengths

  • Heating rises in the cold: 36000 BTU at 47F climbs to 38000 at 17F, then 36000 at 5F.
  • Certified nominal SEER2 23 / EER2 13 / HSPF2 10.7 - the highest HSPF2 here.
  • Current low-GWP R-454B refrigerant, ENERGY STAR certified, AHRI cold-climate designated.
  • Whole-home five-zone coverage with genuine deep-cold performance at a value price.

Weaknesses

  • Sits a notch below top premium brands on brand cachet and dealer network.
  • 36,000 BTU across five zones is modest per room; size each head carefully.

Climate suitability

Minimum heating ambient
-22 F[2]
Rated heating at 5F
36,000 BTU/hNon-Ducted Indoor Units[3]
Rated heating at 17F
38,000 BTU/hNon-Ducted Indoor Units[3]
Rated heating at 47F
36,000 BTU/hNon-Ducted Indoor Units[3]

Specifications

Show
Manufacturer
Cooper & Hunter
Brand
Cooper & Hunter
Product line
Hyper Heat Multi-Zone
Model number
CH-RHP36M-230VO
Indoor unit model
Indoor heads are selected separately on a multi-zone system
Outdoor unit model
CH-RHP36M-230VO
Number of zones
5
Max indoor units
5 units[1]
Rated cooling capacity
36,000 BTU/hNon-Ducted Indoor Units[3]
Rated heating capacity
36,000 BTU/hNon-Ducted Indoor Units[3]
Voltage
230 V[2]
MCA
37 A[2]
Maximum fuse or breaker size
40 A[2]
Breaker needed
not published
SEER2
23 SEER2Non-Ducted Indoor Units[3]
EER2
13 EER2Non-Ducted Indoor Units[3]
HSPF2 (Region 4)
10.7 HSPF2Non-Ducted Indoor Units[3]
HSPF2 (Region 5)
Certified per indoor-unit combination, not per outdoor unit
COP
not published
COP at 47F
4 COP[2]
COP at 5F
2 COPNon-Ducted Indoor Units[3]
Minimum outdoor heating temperature
-22 F[2]
Minimum outdoor cooling temperature
-22 F[2]
Maximum outdoor temperature
122 F[2]
Indoor noise range
Indoor heads are selected separately on a multi-zone system
Outdoor noise rating
65 dBA[2]
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
211.86 lb[2]
Refrigerant
R-454B[3]
Refrigerant charge
134.04 oz[2]
Manufacturer coverage
not published
Line-set size
5 x 1/4 in liquid / 3 x 3/8 in + 2 x 1/2 in suction
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
262.4 ft[2]
Max line set per indoor
114.8 ft[2]
Maximum elevation difference
49.2 ft[2]
Max height between indoor units
33 ft[2]
Wi-Fi support
Indoor heads are selected separately on a multi-zone system
Energy Star status
ENERGY STAR certified[4]
AHRI certification number
217155432Non-Ducted Indoor Units[3]
Warranty
Standard: 5 yr parts / 7 yr compressor (standard registration/installation terms). 7-year compressor, 5-year parts warranty with standard registration/installation terms.
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.
Available retailers
not published
Manual links
AHRI public detail 217155432, ENERGY STAR exact row 217155432, Cooper & Hunter MultiZone combination charts, Cooper & Hunter MultiZone combination charts, Cooper & Hunter Multi R installation manual, Cooper & Hunter Hyper Heat Multi-Zone official product-page evidence for CH-RHP36M-230VO, CH-RHP36M-230VO Cooper & Hunter Hyper Heat Multi-Zone non-ducted outdoor submittal, HVACDirect exact-offer audit for CH-RHP36M-230VO
Specification sheet
not published
Last sourced date
Jul 28, 2026

Compatible indoor units

This is an outdoor unit. You choose its indoor heads separately - up to the maximum this condenser supports - and you can mix room sizes and styles across the zones. The models below are the heads this unit is documented to pair with.

  • Concealed ducteds

    12k, 18k, 24k

    Model numbers
    • 12k: CH-RS06-12MDT- MS
    • 12k: CH-RS06-12MDT-MS
    • 18k: CH-RS18MDT-MS
    • 24k: CH-RS24MDT-HS
  • Four-way ceiling cassettes

    9k, 12k, 18k, 24k

    Model numbers
    • 9k: CH-RH09MCT
    • 12k: CH-RH12MCT
    • 12k: CH-RSH09-12MCT
    • 18k: CH-RH18MCT
    • 18k: CH-RSH18MCT
    • 24k: CH-RH24MCT
    • 24k: CH-RSH24MCT
  • One-way ceiling cassettes

    12k, 18k

    Model numbers
    • 12k: CH-RSH06-12MCT1W
    • 18k: CH-RSH18MCT1W

Sizing note: do not just add up the rooms. Multi-zone condensers have a maximum total connected capacity, and connecting more head capacity than the unit is rated for is a common installer mistake that hurts efficiency and comfort. Match total head capacity to the condenser's rating.

Parts and filters

Fits Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO). Part numbers and fit notes identify compatibility only; no manufacturer endorsement is implied.

compressor-service-identification

Compressor model EKPQ420D1UMUA

Fits
Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO)
Fit note
Fits CH-RHP36M-230VO. Cooper & Hunter publishes the compressor model identifier in the submittal, but this is not an orderable OEM replacement part number; source by outdoor model and serial through Cooper & Hunter or Heat & Cool parts support.
Source
Cooper & Hunter CH-RHP36M-230VO Submittal, Performance data, page p. 2 (Compressor Model EKPQ420D1UMUA)

outdoor-fan-motor

Outdoor fan motor

Fits
Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO)
Fit note
Fits CH-RHP36M-230VO. The submittal documents fan-motor quantity and electrical data but no orderable motor part number; source by outdoor model and serial through Cooper & Hunter or Heat & Cool parts support.
Source
Cooper & Hunter CH-RHP36M-230VO Submittal, Electrical data, page p. 2 (Outdoor fan motor Qty 1 Input w 250 RLA A 2.6)

line-set-port-sizes

Outdoor unit line-set port sizes

Fits
Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO)
Fit note
Fits CH-RHP36M-230VO. The submittal publishes the outdoor port size set, not a packaged replacement part number. No offer is attached because Cooper & Hunter has no verified exact priced retailer offers in the local search outcome file.
Source
Cooper & Hunter CH-RHP36M-230VO Submittal, Piping connections, page p. 2 (Liquid side/Gas side in 5x1/4" - 3x3/8"+2x1/2")
Replacement Parts & Filters

Electrical requirements

Show
Voltage
230 V[2]
Voltage range
208/230V[2]
Phase
1[2]
Frequency
60 Hz[2]
MCA
37 A[2]
Breaker needed
not published
Maximum breaker size
40 A[2]
Maximum fuse size
40 A[2]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
5 x 1/4 in[2]
Suction line
3 x 3/8 in + 2 x 1/2 in[2]
Line connection type
Flared line connections[2]
Precharged length
125 ft[2]
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
262.4 ft[2]
Max line set per indoor
114.8 ft[2]
Max height between indoor units
33 ft[2]
Indoor dimensions
Indoor heads are selected separately on a multi-zone system
Outdoor dimensions
38.58 x 16.34 x 38.39 in[2]
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
211.86 lb[2]
Drain size
not published

Frequently asked questions

Can I install the Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO) myself, or do I need a pro?
Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO) keep heating in a cold winter?
The manufacturer publishes 36,000 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10.7 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO) need?
Published electrical requirements: 230 V voltage, 37 A minimum circuit ampacity, and 40 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 262.4 ft, and the included line set comes pre-charged for 125 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Cooper & Hunter Hyper Heat Multi-Zone 5-Zone 36,000 BTU R-454B 208/230V (CH-RHP36M-230VO) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 7 yr compressor (standard registration/installation terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. Cooper & Hunter: Cooper & Hunter Hyper Heat Multi-Zone official evidence for CH-RHP36M-230VOSourced - manufacturer product page

    Covers brand.dealer_installation_policy, electrical_spec.guaranteed_voltage_range, Max indoor units, product_line.name

  2. Cooper & Hunter: CH-RHP36M-230VO Cooper & Hunter Hyper Heat Multi-Zone non-ducted outdoor submittalSourced - manufacturer technical document

    Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Voltage and more

  3. Air-Conditioning, Heating, and Refrigeration Institute: AHRI public detail 217155432Sourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  4. U.S. Environmental Protection Agency ENERGY STAR: ENERGY STAR exact row check for AHRI 217155432Sourced - Energy Star listing

    Covers performance_spec.energy_star_cold_climate, Energy Star status

  5. Cooper & Hunter MultiZone combination chartsSourced - manual

    Covers Manual links

Last updated

Jul 28, 2026