SplitAtlas

Cooper & Hunter / MIA Series

Cooper & Hunter MIA 12,000 BTU (115V)

Model data is drawn from manufacturer, retailer, and certification sources. Missing specifications remain marked as not published.

1 zoneWall-mountedNot publishedCurrent
Data completeness: 83%
Last verified
Jul 18, 2026

SplitAtlas score

not yet rated - data incomplete

Methodology
  • no scoring run is available

1. Summary

The MIA 12k is the value entry among our published 115V units: a simple, widely available unit at a lower typical price, with the trade-offs you would expect - lower certified efficiency and thinner published documentation than the class leaders.

Rated cooling

12,000BTU/hVerified - AHRI certificate

Rated heating

12,000BTU/hVerified - AHRI certificate

2. Best-fit use cases

Budget-driven cooling-first purchases - rentals, bonus rooms, mild climates - where the upfront price matters more than heating performance or long-run efficiency.

3. Key specifications

Manufacturer
Cooper & Hunter
Brand
Cooper & Hunter
Product line
MIA Series
Model number
CH-RLS12MIA-115VI indoor / CH-RLS12MIA-115VO outdoor
Indoor unit model
CH-RLS12MIA-115VI
Outdoor unit model
CH-RLS12MIA-115VO
Number of zones
1
Max indoor units
not published
Rated cooling capacity
12,000 BTU/hVerified - AHRI certificate
Rated heating capacity
12,000 BTU/hVerified - AHRI certificate
Voltage
115 VVerified - manufacturer technical document
MCA
19 AVerified - manufacturer technical document
Maximum fuse or breaker size
20 AVerified - manufacturer technical document
Breaker needed
not published
SEER2
21.2 SEER2Verified - AHRI certificate
EER2
10.1 EER2Verified - AHRI certificate
HSPF2 (Region 4)
8.7 HSPF2Verified - AHRI certificate
HSPF2 (Region 5)
6.7 HSPF2Verified - manufacturer technical document
COP
not published
COP at 47F
not published
COP at 5F
not published
Minimum outdoor heating temperature
not published
Minimum outdoor cooling temperature
5 FVerified - manufacturer technical document
Maximum outdoor temperature
122 FVerified - manufacturer technical document
Indoor noise range
40.5/32.5/25 dB(A)Verified - manufacturer technical document
Outdoor noise rating
54 dBAVerified - manufacturer technical document
Indoor weight
19.4 lbVerified - manufacturer technical document
Outdoor weight
61.29 lbVerified - manufacturer technical document
Refrigerant
R-454BVerified - manufacturer technical document
Refrigerant charge
24.34 ozVerified - manufacturer technical document
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
not published
Maximum line-set length
not published
Max line set per indoor
not published
Maximum elevation difference
not published
Max height between indoor units
not published
Wi-Fi support
not published
Energy Star status
not publishedVerified - manufacturer technical document
AHRI certification number
216623803Verified - AHRI certificate
Warranty
5 years parts / 7 years compressor. 7-year compressor and 5-year parts warranty, registration required.
DIY installation status
Not published
Retail price
$1,050.00
Installation type
Wall-mounted
Available retailers
MiniSplitWarehouse
Manual links
AHRI Certificate of Product Ratings ref 216623803, CH-RLS12MIA submittal data sheet
Specification sheet
CH-RLS12MIA submittal data sheet
Last verified date
Jul 18, 2026

Some retailer links may earn us a commission at no extra cost; paid relationships never change scores or recommendations. Affiliate disclosure

Paid link

Check price at MiniSplitWarehouse

$1,050 / Fresh price - checked Jul 18, 2026

4. Strengths

  • 115V operation for straightforward retrofit wiring.
  • Published 25 dB(A) low fan level - quiet enough for bedrooms.
  • Typically the lowest equipment price among our published 12k systems.

5. Weaknesses

  • Certified efficiency (SEER2 21.2 / HSPF2 8.7) sits at the bottom of our published 12k class - the operating-cost gap versus the AURA compounds over years of all-day use.
  • Low-ambient heating performance is not published - do not plan on it as a primary cold-climate heat source.
  • Published documentation is thinner than MRCOOL or Senville; several specs on our page read "not published" because the manufacturer does not publish them.

6. Climate suitability

Minimum heating ambient
not published
Rated heating at 5F
not published
Rated heating at 17F
not published
Rated heating at 47F
not published

7. Electrical requirements

Voltage
115 VVerified - manufacturer technical document
Voltage range
not published
Phase
1Verified - manufacturer technical document
Frequency
60 HzVerified - manufacturer technical document
MCA
19 AVerified - manufacturer technical document
Breaker needed
not published
Maximum breaker size
not published
Maximum fuse size
20 AVerified - manufacturer technical document
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

8. Installation considerations

Liquid line
1/4 inVerified - manufacturer technical document
Suction line
3/8 inVerified - manufacturer technical document
Precharged length
25 ftVerified - manufacturer technical document
Included line-set length
not published
Maximum line-set length
not published
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
31.57 x 7.44 x 11.69 inVerified - manufacturer technical document
Outdoor dimensions
30.12 x 11.93 x 21.85 inVerified - manufacturer technical document
Indoor weight
19.4 lbVerified - manufacturer technical document
Outdoor weight
61.29 lbVerified - manufacturer technical document
Drain size
not published

9. Operating-cost estimate

not published

10. Comparable models

Frequently asked questions

Can I install the Cooper & Hunter MIA 12,000 BTU (115V) myself, or do I need a pro?
Cooper & Hunter MIA 12,000 BTU (115V) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Cooper & Hunter MIA 12,000 BTU (115V) keep heating in a cold winter?
Certified heating efficiency is 8.7 HSPF2. Match that published heating floor against your climate's design temperature - below the low-ambient rating, output can fall off or the system can pause to protect itself.
What electrical circuit does the Cooper & Hunter MIA 12,000 BTU (115V) need?
Published electrical requirements: 115 V voltage, 19 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
What warranty does the Cooper & Hunter MIA 12,000 BTU (115V) carry?
The manufacturer publishes 5 years parts coverage and 7 years compressor coverage. Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

11. Data sources

12. Last updated date

Jul 19, 2026