Della / Serena Series Multi-Zone
Della Serena 18k R-32 208/230V 2-Zone Mini-Split
The Della Serena 2-Zone 18k is Della's entry two-zone system, pairing two indoor heads with one 208/230V outdoor unit on current R-32 refrigerant. It posts a nominal SEER2 of 22, EER2 12.3, HSPF2 10, is ENERGY STAR certified and AHRI cold-climate designated.
Cooling is rated at 17,700 BTU, and rated heating falls off in the cold, from 18,000 BTU at 47F to 14,700 at 17F and 14,500 at 5F. Professional installation required; dealer-quoted.
Refrigerant generation
R-32 - current-generation refrigerant
Need this installed?
Get installation quotes
Image: Della
- Last sourced
- Jul 28, 2026
SplitAtlas score
8.4 / 10
(22.0 SEER2) among 18k systems
(10.0 HSPF2) among 18k systems
(80.6% heat retained at 5F; -13 F heating floor) among 18k systems
(6 verified features) across the catalogue
(6 manuals; spec sheet) across the catalogue
Not evaluated
- Installation accessibility — not applicable (professional install)N/A
professional install - DIY-accessibility not applicable
- Price-to-value — not evaluatedN/A
This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.
Get a quote
Key ratings
Buyer review snapshot
Best for / skip if
Best for
- 2-zone projects in the 18k outdoor capacity class.
- High-efficiency shortlists; SEER2 is 22.
Install difficulty
- Electrical: 230V; MCA 15 A; breaker/fuse 20 A.
- Line set: Flared line connections; precharged 25 ft; max 82 ft.
- 2-zone condenser; indoor-head matching and branch layout are part of the job.
Alternatives
- ACiQ Multi-Zone Extreme Series 2-Zone 18,000 BTU R-454B 208/230V (ACIQ-18Z-HH-M3C)
8.9 score / 19k / SEER2 25 / -22 F heating floor / 230V
Exact destination at HVACDirect: $2,549.99, checked Jul 29, 2026
- ACiQ Multi-Zone Standard Series 2-Zone 18,000 BTU R-454B 208/230V (ES-18Z-M3C)
8.5 score / 18k / SEER2 25.1 / -13 F heating floor / 230V
Exact destination at HVACDirect: $1,499.99, checked Jul 29, 2026
Availability and price context
We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.
Source date
- Model data sourced
- Jul 28, 2026
- Page reviewed
- Jul 28, 2026
- Source-backed records
- 4
- Newest source retrieved
- Jul 28, 2026
Warranty tiers
Warranty: Della warranty terms vary by registration and installation context; product pages expose Warranty Registration / Warranty Policy links.
Model context
- Install path
- This is professional-install equipment; no verified current retail offer is attached.
- Structured ratings
- Certification: ENERGY STAR certified, ENERGY STAR cold-climate certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-32. Minimum heating ambient: -13 F.
Strengths
- Entry two-zone with a certified nominal SEER2 22 / EER2 12.3 / HSPF2 10.
- Value-priced certified two-zone from an online-focused brand.
Weaknesses
- Rated heating falls off in deep cold, down to 14,500 BTU at 5F.
- 17,700 BTU across two zones is modest per room; size each head.
Climate suitability
- Minimum heating ambient
- -13 F[1]
- Rated heating at 5F
- 14,500 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 17F
- 14,700 BTU/hNon-Ducted Indoor Units[3]
- Rated heating at 47F
- 18,000 BTU/hNon-Ducted Indoor Units[3]
Specifications
ShowHide
- Manufacturer
- Della
- Brand
- Della
- Product line
- Serena Series Multi-Zone
- Model number
- 048-MS-18K-MODU
- Indoor unit model
- Indoor heads are selected separately on a multi-zone system
- Outdoor unit model
- 048-MS-18K-MODU
- Number of zones
- 2
- Max indoor units
- 2 units[2]
- Rated cooling capacity
- 17,700 BTU/hNon-Ducted Indoor Units[3]
- Rated heating capacity
- 18,000 BTU/hNon-Ducted Indoor Units[3]
- Voltage
- 230 V[2]
- MCA
- 15 A[2]
- Maximum fuse or breaker size
- 20 A[2]
- Breaker needed
- not published
- SEER2
- 22 SEER2Non-Ducted Indoor Units[3]
- EER2
- 12.3 EER2Non-Ducted Indoor Units[3]
- HSPF2 (Region 4)
- 10 HSPF2Non-Ducted Indoor Units[3]
- HSPF2 (Region 5)
- Certified per indoor-unit combination, not per outdoor unit
- COP
- not published
- COP at 47F
- not published
- COP at 5F
- 2 COPNon-Ducted Indoor Units[3]
- Minimum outdoor heating temperature
- -13 F[1]
- Minimum outdoor cooling temperature
- not published
- Maximum outdoor temperature
- 131 F[1]
- Indoor noise range
- Indoor heads are selected separately on a multi-zone system
- Outdoor noise rating
- 54 dBA[2]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 75 lb[2]
- Refrigerant
- R-32[3]
- Refrigerant charge
- 38.8 oz[2]
- Manufacturer coverage
- not published
- Line-set size
- 1/4 in liquid / 3/8 in suction
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 82 ft[2]
- Max line set per indoor
- 82 ft[2]
- Maximum elevation difference
- 49 ft[2]
- Max height between indoor units
- not published
- Wi-Fi support
- Indoor heads are selected separately on a multi-zone system
- Energy Star status
- ENERGY STAR certified[4]
- AHRI certification number
- 217175305Non-Ducted Indoor Units[3]
- Warranty
- Della warranty terms vary by registration and installation context; product pages expose Warranty Registration / Warranty Policy links.
- Install path
- Professional install
- Retail price
- We could not find this exact model in stock at a retailer we work with when we last checked on 2026-07-28.
- Available retailers
- not published
- Manual links
- AHRI public detail 217175305, ENERGY STAR exact row 217175305, Della Serena Series Multi-Zone installation manual for 048-MS-18K-MODU, Della Serena Series Multi-Zone official product page example for 048-MS-18K-MODU, HVACDirect exact-offer audit for 048-MS-18K-MODU, Della Serena Series Multi-Zone manual technical tables for 048-MS-18K-MODU
- Specification sheet
- Della Serena Series Multi-Zone manual technical tables for 048-MS-18K-MODU
- Last sourced date
- Jul 28, 2026
Installation considerations
ShowHide
- Liquid line
- 1/4 in[2]
- Suction line
- 3/8 in[2]
- Line connection type
- Flared line connections[2]
- Precharged length
- 25 ft[2]
- Included line-set length
- Indoor heads are selected separately on a multi-zone system
- Maximum line-set length
- 82 ft[2]
- Max line set per indoor
- 82 ft[2]
- Max height between indoor units
- not published
- Indoor dimensions
- Indoor heads are selected separately on a multi-zone system
- Outdoor dimensions
- 34.65 x 13.90 x 21.93 in[2]
- Indoor weight
- Indoor heads are selected separately on a multi-zone system
- Outdoor weight
- 75 lb[2]
- Drain size
- not published
Related systems and guides
- More Della systems
- ACiQ Multi-Zone Essentials 17.7k 230V
- ACiQ Essentials 18k
- Della Econo Series 17k 230V
- Motto Series 18k
- Guide library
- Mini split buying guide
- Single-zone vs multi-zone mini splits
- Troubleshooting
- Do mini splits work in cold weather?
- Della mini split review: is Della any good?
- The best multi-zone mini splits of 2026
- The best 2-zone (dual-zone) mini splits of 2026
- How to size a multi-zone mini split
- Not every multi-zone condenser lets you mix head types
- How much does a multi-zone mini split cost?
- The best cold-climate mini splits of 2026
- The best mini splits for heating of 2026
- Mini split heating capacity in the cold: what your unit actually delivers at 5F
- One room won't heat or cool on a multi-zone mini split
- Mini split not heating
- Mini split indoor unit freezing up
- Mini split remote not working
- Mini split short cycling
- Line sets
- Line-set covers
Frequently asked questions
- Can I install the Della Serena Series Multi-Zone 2-Zone 18,000 BTU R-32 208/230V (048-MS-18K-MODU) myself, or do I need a pro?
- Della Serena Series Multi-Zone 2-Zone 18,000 BTU R-32 208/230V (048-MS-18K-MODU) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
- Will the Della Serena Series Multi-Zone 2-Zone 18,000 BTU R-32 208/230V (048-MS-18K-MODU) keep heating in a cold winter?
- The manufacturer publishes 14,500 BTU/h of heating output at 5F. Rated heating operation extends down to -13 F. Certified heating efficiency is 10 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
- What electrical circuit does the Della Serena Series Multi-Zone 2-Zone 18,000 BTU R-32 208/230V (048-MS-18K-MODU) need?
- Published electrical requirements: 230 V voltage, 15 A minimum circuit ampacity, and 20 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
- How far can the outdoor unit be from the indoor head?
- The published maximum line-set length is 82 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
Data sources
ShowHide
- Della: Della Serena Series Multi-Zone official product-page evidence for 048-MS-18K-MODUSourced - manufacturer product page
Covers brand.dealer_installation_policy, Minimum outdoor heating temperature, Maximum outdoor temperature, product_line.name, Warranty notes
- Della: Della Serena Series Multi-Zone official manual technical table for 048-MS-18K-MODUSourced - manufacturer technical document
Covers Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase, Manufacturer wire notes and more
- AHRI certificate #217175305 - search the AHRI DirectorySourced - AHRI directory
Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more
- ENERGY STAR record for AHRI #217175305 - search ENERGY STARSourced - Energy Star listing
Covers performance_spec.energy_star_cold_climate, Energy Star status
Last updated
Jul 28, 2026