SplitAtlas

Blueridge / XM2 All Climate

Blueridge XM2 All Climate 24k R-32 208/230V 3-Zone Mini-Split

Certified capacity
24,000 BTU/h[2]
SEER2
21 SEER2[2]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The Blueridge XM2 All Climate 3-Zone 24k delivers cold-climate performance across three heads on one 208/230V R-32 outdoor unit. Certified nominal SEER2 is 21, EER2 13.3, HSPF2 10.0.

Heating holds strong into the cold: 24,000 BTU at 47F, 23,600 at 17F, and 21,600 at 5F. It is ENERGY STAR certified and AHRI cold-climate designated.

Sold through dealer quote; DIY-marketed, but flared connections require professional vacuum and startup.

3 zonesProfessional installCurrent

Refrigerant generation

R-32 - current-generation refrigerant

Need this installed?

Get installation quotes
Data completeness: 95%
Last sourced
Aug 29, 2026

SplitAtlas score

8.3 / 10

Methodology
Cooling efficiencyBelow average

(21.0 SEER2) among 24k systems

Heating efficiencyAbove average

(10.0 HSPF2) among 24k systems

Cold-weather performanceAbove average

(90% heat retained at 5F; -22 F heating floor) among 24k systems

WarrantyBelow average

(5 yr parts / 7 yr compressor) across the catalogue

Feature setAbove average

(5 verified features) across the catalogue

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

24,000BTU/hNon-Ducted Indoor Units[2]

Rated heating

24,000BTU/hNon-Ducted Indoor Units[2]

Buyer review snapshot

Best for / skip if

Best for

  • 3-zone projects in the 24k outdoor capacity class.

Install difficulty

Professional flared-line install
  • Electrical: 230V; MCA 19.5 A; breaker/fuse 25 A.
  • Line set: Flared line connections; precharged 98 ft; max 196.85 ft.
  • 3-zone condenser; indoor-head matching and branch layout are part of the job.

Alternatives

Availability and price context

We could not verify a current retail price for this model. We could not find this exact model in stock at a retailer we work with when we last checked on 2026-08-29.

Source date

Model data sourced
Aug 29, 2026
Page reviewed
Jul 29, 2026
Source-backed records
5
Newest source retrieved
Aug 29, 2026

Warranty tiers

Warranty: 5 years parts and 7 years compressor as standard.

Review methodology

Model context

Install path
This is professional-install equipment; no verified current retail offer is attached.
Structured ratings
Certification: ENERGY STAR certified, ENERGY STAR cold-climate certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-32. Minimum heating ambient: -22 F.
Installation context
Multi-zone low-load behavior depends on the indoor heads and how many zones are calling at once.

Strengths

  • Heating holds near full through the cold (21,600 BTU at 5F).
  • Certified nominal SEER2 21, EER2 13.3, HSPF2 10.0.
  • Low-GWP R-32, ENERGY STAR certified.
  • AHRI cold-climate designated across three zones.

Weaknesses

  • SEER2 21 cooling trails the high-efficiency Core tier.

Climate suitability

Minimum heating ambient
-22 F[1]
Rated heating at 5F
21,600 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 17F
23,600 BTU/hNon-Ducted Indoor Units[2]
Rated heating at 47F
24,000 BTU/hNon-Ducted Indoor Units[2]

Specifications

Show
Manufacturer
Blueridge
Brand
Blueridge
Product line
XM2 All Climate
Model number
BXM2Z24UC0
Indoor unit model
Indoor heads are selected separately on a multi-zone system
Outdoor unit model
BXM2Z24UC0
Number of zones
3
Max indoor units
3 units[1]
Rated cooling capacity
24,000 BTU/hNon-Ducted Indoor Units[2]
Rated heating capacity
24,000 BTU/hNon-Ducted Indoor Units[2]
Voltage
230 V[1]
MCA
19.5 A[1]
Maximum fuse or breaker size
25 A[1]
Breaker needed
not published
SEER2
21 SEER2Non-Ducted Indoor Units[2]
EER2
13.3 EER2Non-Ducted Indoor Units[2]
HSPF2 (Region 4)
10 HSPF2Non-Ducted Indoor Units[2]
HSPF2 (Region 5)
Certified per indoor-unit combination, not per outdoor unit
COP
not published
COP at 47F
not published
COP at 5F
2 COPNon-Ducted Indoor Units[2]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
-22 F[1]
Maximum outdoor temperature
118 F[1]
Indoor noise range
Indoor heads are selected separately on a multi-zone system
Outdoor noise rating
not published
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
112.5 lb[1]
Refrigerant
R-32[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
(3) 1/4 in liquid / (3) 3/8 in suction
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
196.85 ft[1]
Max line set per indoor
65.6 ft[1]
Maximum elevation difference
49.2 ft[1]
Max height between indoor units
not published
Wi-Fi support
Indoor heads are selected separately on a multi-zone system
Energy Star status
ENERGY STAR certified[3]
AHRI certification number
217448534Non-Ducted Indoor Units[2]
Warranty
Standard: 5 yr parts / 7 yr compressor (limited warranty terms). 5-year parts, 7-year compressor warranty.
Install path
Professional install
Retail price
We could not find this exact model in stock at a retailer we work with when we last checked on 2026-08-29.
Available retailers
not published
Manual links
AHRI public detail 217448534, ENERGY STAR exact row 217448534, Blueridge XM2 All Climate installation/user manual listed for BXM2Z24UC0, Blueridge XM2 All Climate official product/category evidence for BXM2Z24UC0, HVACDirect exact-offer audit for BXM2Z24UC0, Blueridge BXM2Z24UC0 specification sheet listed by Alpine
Specification sheet
Blueridge BXM2Z24UC0 specification sheet listed by Alpine
Last sourced date
Aug 29, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
19.5 A[1]
Breaker needed
not published
Maximum breaker size
25 A[1]
Maximum fuse size
25 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
not published

Installation considerations

Show
Liquid line
(3) 1/4 in[1]
Suction line
(3) 3/8 in[1]
Line connection type
Flared line connections[1]
Precharged length
98 ft[1]
Included line-set length
Indoor heads are selected separately on a multi-zone system
Maximum line-set length
196.85 ft[1]
Max line set per indoor
65.6 ft[1]
Max height between indoor units
not published
Indoor dimensions
Indoor heads are selected separately on a multi-zone system
Outdoor dimensions
37.95 x 25.98 x 15.83 in[1]
Indoor weight
Indoor heads are selected separately on a multi-zone system
Outdoor weight
112.5 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Blueridge XM2 All Climate 3-Zone 24,000 BTU R-32 208/230V (BXM2Z24UC0) myself, or do I need a pro?
Blueridge XM2 All Climate 3-Zone 24,000 BTU R-32 208/230V (BXM2Z24UC0) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Blueridge XM2 All Climate 3-Zone 24,000 BTU R-32 208/230V (BXM2Z24UC0) keep heating in a cold winter?
The manufacturer publishes 21,600 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 10 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Blueridge XM2 All Climate 3-Zone 24,000 BTU R-32 208/230V (BXM2Z24UC0) need?
Published electrical requirements: 230 V voltage, 19.5 A minimum circuit ampacity, and 25 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 196.85 ft, and the included line set comes pre-charged for 98 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Blueridge XM2 All Climate 3-Zone 24,000 BTU R-32 208/230V (BXM2Z24UC0) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 7 yr compressor (limited warranty terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. Blueridge / Alpine Home Air Products: Flared line set and professional startup evidenceSourced - manufacturer technical document

    Covers brand.dealer_installation_policy, Frequency, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. AHRI certificate #217448534 - search the AHRI DirectorySourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Rated heating capacity and more

  3. ENERGY STAR record for AHRI #217448534 - search ENERGY STARSourced - Energy Star listing

    Covers performance_spec.energy_star_cold_climate, Energy Star status

  4. Blueridge / Alpine Home Air Products: Flared line set and professional startup evidenceSourced - manufacturer technical document

    Covers system.diy_status, system.installation_type, system.sales_intent

  5. Alpine Home Air Products: Blueridge XM3 All Climate Plus official product/category evidence for BXM3A36UC0Sourced - manufacturer product page

    Covers Standard compressor warranty, Standard warranty conditions, Standard parts warranty

Last updated

Jul 29, 2026