SplitAtlas

Cooper & Hunter / One-Way Cassette

Cooper Hunter One-Way Cassette 7k Hyper R-454B 208/230V Mini-Split

Certified capacity
6,500 BTU/h[2]
SEER2
22 SEER2[2]
Heating floor
-22 F[1]
Voltage
230 V[1]
Install path
Professional install

The smallest unit in this batch: a one-way ceiling cassette rated 6,500 BTU cooling and 7,400 heating, certifying at 22 SEER2 and 12 HSPF2 with a -22F rating.

One-way cassettes exist for rooms that four-way heads handle badly - long, narrow spaces, or ceilings too shallow to take a square head. At 6,500 BTU this is a genuinely small unit, which is unusual and useful: most mini-splits start at 9,000 BTU and are oversized for a small room, where they short-cycle and dehumidify poorly.

1 zoneProfessional installCurrent

Refrigerant generation

R-454B - current-generation refrigerant

Need this installed?

Get installation quotes
Data completeness: 92%
Last sourced
Aug 2, 2026

SplitAtlas score

8.5 / 10

Methodology
Cooling efficiencyBelow average

(22.0 SEER2) among <=9k systems

Heating efficiencyAbove average

(12.0 HSPF2) among <=9k systems

Cold-weather performanceTop quartile

(100% heat retained at 5F; -22 F heating floor) among <=9k systems

WarrantyBelow average

(5 yr parts / 7 yr compressor) across the catalogue

Feature setAbove average

(6 verified features) across the catalogue

Documentation & partsBelow average

(6 manuals; spec sheet) across the catalogue

Not evaluated

  • Installation accessibility — not applicable (professional install)N/A

    professional install - DIY-accessibility not applicable

  • Price-to-value — not evaluatedN/A

    This is a professionally installed, quote-only system, so we can't score its price. Get an installed quote to compare real cost.

    Get a quote

Key ratings

Rated cooling

6,500BTU/h[2]

Rated heating

7,400BTU/h[2]

Buyer review snapshot

Best for / skip if

Best for

  • High-efficiency shortlists; SEER2 is 22.

Install difficulty

Professional flared-line install
  • Electrical: 230V; MCA 12 A; breaker/fuse 15 A.
  • Line set: Flared line connections; precharged 25 ft; max 82 ft.

Alternatives

Availability and price context

We could not verify a current retail price for this model. We do not currently have a verified in-stock offer from a retailer we work with when we last checked on 2026-08-02.

Source date

Model data sourced
Aug 2, 2026
Page reviewed
Aug 2, 2026
Source-backed records
3
Newest source retrieved
Aug 2, 2026

Warranty tiers

Warranty: 5 years parts and 7 years compressor as standard.

Review methodology

Model context

Structured ratings
Certification: ENERGY STAR certified and AHRI cold-climate designated. Refrigerant: current low-GWP R-454B. Minimum heating ambient: -22 F.

Strengths

  • 6,500 BTU is small enough to right-size a room that a 9k unit would oversize.
  • 12 HSPF2 with a -22F rating - strong cold-climate heating.
  • Shallow one-way housing fits ceiling cavities that reject a four-way head.

Weaknesses

  • Directional throw makes placement unforgiving in an awkward room.
  • The 7k badge is optimistic - certified cooling is 6,500 BTU.
  • Professional install with cavity and condensate requirements.

Climate suitability

Minimum heating ambient
-22 F[1]
Rated heating at 5F
8,100 BTU/h[2]
Rated heating at 17F
7,000 BTU/h[2]
Rated heating at 47F
7,400 BTU/h[2]

Specifications

Show
Manufacturer
Cooper & Hunter
Brand
Cooper & Hunter
Product line
One-Way Cassette
Model number
CH-RSH06-12MCT1W indoor / CH-RHP06F9-230VO outdoor
Indoor unit model
CH-RSH06-12MCT1W
Outdoor unit model
CH-RHP06F9-230VO
Number of zones
1
Max indoor units
not published
Rated cooling capacity
6,500 BTU/h[2]
Rated heating capacity
7,400 BTU/h[2]
Voltage
230 V[1]
MCA
12 A[1]
Maximum fuse or breaker size
15 A[1]
Breaker needed
not published
SEER2
22 SEER2[2]
EER2
15 EER2[2]
HSPF2 (Region 4)
12 HSPF2[2]
HSPF2 (Region 5)
not published
COP
not published
COP at 47F
not published
COP at 5F
2.4 COP[2]
Minimum outdoor heating temperature
-22 F[1]
Minimum outdoor cooling temperature
-22 F[1]
Maximum outdoor temperature
122 F[1]
Indoor noise range
not published
Outdoor noise rating
52.5 dBA[1]
Indoor weight
not published
Outdoor weight
62.17 lb[1]
Refrigerant
R-454B[2]
Refrigerant charge
not published
Manufacturer coverage
not published
Line-set size
1/4 in liquid / 3/8 in suction
Included line-set length
C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
Maximum line-set length
82 ft[1]
Max line set per indoor
not published
Maximum elevation difference
49.2 ft[1]
Max height between indoor units
not published
Wi-Fi support
supported[1]
Energy Star status
ENERGY STAR certified[2]
AHRI certification number
215864251[2]
Warranty
Standard: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). 7-year compressor and 5-year parts limited warranty with licensed-technician installation and registration terms.
Install path
Professional install
Retail price
We do not currently have a verified in-stock offer from a retailer we work with when we last checked on 2026-08-02.
Available retailers
not published
Manual links
AHRI Active public directory row 215864251, One Way Cassette Installation Manual, Cooper & Hunter Multi R installation manual, Cooper & Hunter One-Way Cassette official product pages for CH-RSH06-12MCT1W, Owner's Manual One Way Cassette, Cooper & Hunter support-material submittal for CH-RHP06F9-230VO + CH-RSH06-12MCT1W
Specification sheet
Cooper & Hunter support-material submittal for CH-RHP06F9-230VO + CH-RSH06-12MCT1W
Last sourced date
Aug 2, 2026

Electrical requirements

Show
Voltage
230 V[1]
Voltage range
208/230V[1]
Phase
1[1]
Frequency
60 Hz[1]
MCA
12 A[1]
Breaker needed
not published
Maximum breaker size
15 A[1]
Maximum fuse size
15 A[1]
Maximum cooling current
not published
Maximum heating current
not published
Manufacturer wire notes
Field wiring per C&H support-material submittal and local electrical code.[1]

Installation considerations

Show
Liquid line
1/4 in[1]
Suction line
3/8 in[1]
Line connection type
Flared line connections[1]
Precharged length
25 ft[1]
Included line-set length
C&H cassette and slim-duct systems are professional-install equipment; the installer supplies the refrigerant line set within published piping limits.
Maximum line-set length
82 ft[1]
Max line set per indoor
not published
Max height between indoor units
not published
Indoor dimensions
not published
Outdoor dimensions
30.12 x 11.93 x 21.85 in[1]
Indoor weight
not published
Outdoor weight
62.17 lb[1]
Drain size
not published

Frequently asked questions

Can I install the Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO) myself, or do I need a pro?
Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO) is built for professional installation: the line set must be flared, evacuated, and charged, which requires EPA-certified refrigerant handling. Installing it outside the manufacturer's requirements can void the warranty, so budget for a qualified HVAC installer.
Will the Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO) keep heating in a cold winter?
The manufacturer publishes 8,100 BTU/h of heating output at 5F. Rated heating operation extends down to -22 F. Certified heating efficiency is 12 HSPF2. Match those numbers against your climate's design temperature - in cold regions, output at 5F matters far more than the nameplate capacity measured at 47F.
What electrical circuit does the Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO) need?
Published electrical requirements: 230 V voltage, 12 A minimum circuit ampacity, and 15 A maximum breaker or fuse sizing. Confirm the final circuit against the unit nameplate and local code with a licensed electrician.
How far can the outdoor unit be from the indoor head?
The published maximum line-set length is 82 ft, and the included line set comes pre-charged for 25 ft. Longer runs than the included set allows typically mean added refrigerant and a pro visit, so measure the planned routing before ordering.
What warranty does the Cooper & Hunter One-Way Ceiling Cassette 7,000 BTU R-454B 208/230V (CH-RSH06-12MCT1W / CH-RHP06F9-230VO) carry?
The manufacturer publishes these warranty tiers: Standard: 5 yr parts / 7 yr compressor (licensed-technician installation and registration terms). Registration requirements and proof of qualified installation commonly affect coverage, so read the warranty terms before install day.

Data sources

Show
  1. Cooper & Hunter: Cooper & Hunter support-material submittal for CH-RHP12-230VO + CH-RSH06-12MCT1WSourced - manufacturer technical document

    Covers Frequency, electrical_spec.guaranteed_voltage_range, Maximum breaker size, Maximum fuse size, Minimum circuit ampacity, Phase and more

  2. Air-Conditioning, Heating, and Refrigeration Institute: AHRI Active Cooper & Hunter form-factor row 215864231Sourced - AHRI directory

    Covers AHRI certification number, performance_spec.cold_climate_designation, Rated cooling capacity, COP at 5F, EER2, Energy Star status and more

  3. Cooper & Hunter: Cooper & Hunter Multi R installation manual limited warranty sectionSourced - manufacturer technical document

    Covers Legacy compressor warranty value, Legacy warranty value, Standard compressor warranty, Standard warranty conditions, Standard parts warranty, Warranty notes

Last updated

Aug 2, 2026